UPOWER Ecoline UE-12Li60 User manual

01010101
1. General Information
This specification defines the performance of rechargeable LiFePO4 battery pack UE-12Li60 manufactured by
UPOWER, S.L., describes the type, performance, technical characteristics, warning and caution of the battery
pack.
Multi-application - LiFePO4 Power
UE-12Li60
Issued Date > 2016-10-13
Issued Version > V02
LITHIUM IRON PHOSPHATE BATTERY
2. Specification
NO. Items Description
12.8V
60Ah
≤40mΩ
Nominal Voltage
Normal Capacity
Internal Resistance
Recommended charge current
Recommended float charge voltage
(for Standby use)
Allowed MAX charge current
0~45°C
14.6±0.1V
50A @ Battery initial Temp 25±5°C
1
2
3
4
5
6
7
8
Normal Specification
Standard Charge
Battery operation temperature range @charging
Normal charge voltage
13.8±0.1V
≤30A
www.upowerbatteries.com
66A Tzar Asen Srt.
Sofia, Republic of Bulgary
Tel. (+34) 918 021 649
Fax. (+34) 917 750 542

UE-12Li60
NO. Items Description
-20~60°C
8.0~14.6V
50A withstand 30min @Battery initial Temp 25±5°C
170A withstand 3s
8.0V
Battery operation temperature range
@discharging
Output Voltage Range
Allowed discharge current
Pulse discharge current
Discharge Cut-off voltage
Dimension
Weight
Storage Temperature
& Humidity Range
Length: 260±2mm
Width: 167.5±2mm
Height: 211±2mm
8.5±0.5Kg
-20~35°C, 45~75% RH
9
10
11
13
14
15
16
17
Standard Discharge
Mechanical Characteristics
Storage
Self-discharge rate
18
Short: within one month
Long term:
above one month -10~30°C, 45~75% RH
≤3% per month; ≤15% per yearResidual capacity
≤1.5% per month; ≤8% per yearReversible capacity
≤50ARecommended discharge current12
01010102
www.upowerbatteries.com
66A Tzar Asen Srt.
Sofia, Republic of Bulgary
Tel. (+34) 918 021 649
Fax. (+34) 917 750 542

3. Electrical Characteristics & Test Condition
Testing Conditions: Ambient Temperature: 25±5ºC; Huminity: 45%~75%.
UE-12Li60
NO. Items
Capacity2
3
4
-20°C
Condition
Internal Impedance1≤40mΩ Test the internal resistance of 50% SOC battery pack
with 1 kHz AC internal resistance test instrument.
Criterion
Rest for 1 hour after fully charged, then discharge
with 0.33C current until the battery reaches the
discharge cutoff voltage. Repeat above process for
three times, if the discharge time is not less than 180
minutes, you can stop and define the Discharging
current*time value (Ah) as battery capacity.
≥58.8Ah
Discharge
Temperature
Characteristics
At 25±5°C discharge the battery with the current of
0.33C to the cut-off voltage. Store the battery at
various temperatures for 2h and discharge the
battery with 0.33C to the cut-off voltage. Record the
ratio between discharging & charging capacity.
0°C
25°C
55°C
≥70%
≥80%
100%
≥95%
Short circuit protection
Automatically cutoff
discharging when
short circuit, and
release after remove
the lead.
Connect the positive and negative of this battery
pack through a lead with the resistance less than
5mΩ.
Charging with this current for more than 0.5h and the
added temperature of battery pack less than 20°C.
MAX charge Current 50A
5
Discharging with this current for more than 0.5h and
the added temperature of battery pack less than
35°C.
MAX discharge Current 50A
Discharge with the current of 0.5C until it can’t
discharge, and then rest it for 1h. Charge the battery
following CC (0.33C)/CV (14.6V) mode to full capacity,
and then rest it for 1h. Repeat above process until full
charged capacity is no more than 80% of normal
value. Accumulated times is defined as cycle life.
6Cycle life (DOD%100) ≥2500 cycles
7
8Charge the battery to full capacity and store it for 28
days, and then discharge it with 0.33C to the cut-off
voltage.
Charge Retention
ability
Remain capacity
≥90%
01010103
www.upowerbatteries.com
66A Tzar Asen Srt.
Sofia, Republic of Bulgary
Tel. (+34) 918 021 649
Fax. (+34) 917 750 542

4. Circuit Protection
The batteries are supplied with a LiFePO4 Battery Management System (BMS) that can monitor and optimized
each single prismatic cell during charge & discharge, to protect the battery pack overcharge, over discharge,
short circuit. Overall, the BMS helps to ensure safe and accurate running.
UE-12Li60
Test Item
Over-charge protection for each cell
CriterionContent
3.80±0.03V
Over charge Over-charge release for each cell 3.60±0.05V
Over-charge release method Under the release voltage
Over-discharge protection for each cell 2.00±0.05V
Over discharge Over-discharge release for each cell 2.30±0.05V
Over-discharge release method Charging
Discharge over current protection 170~220A
Over current Protection delay time 0.5~1.5ms
Over current release method Release after cutoff the load
Over Temperature Battery over temperature
Protection @65±5°C
Release @50±5°C
5. Dimensional Drawing
01010104
www.upowerbatteries.com
66A Tzar Asen Srt.
Sofia, Republic of Bulgary
Tel. (+34) 918 021 649
Fax. (+34) 917 750 542

Please read and follow the specification and caution remarks on battery surface before use the battery.
Improper use may cause heat, fire, rupture, damage or capacity deterioration of the battery.
UPOWER, S.L. Describes is not responsible for any accidents caused by the usage without following our
specification.
Warning!
• The battery must be far away from heat source, high voltage, and avoid to be exposed in sunshine for long time.
• Never throw the battery into water.
• Never connect the positive and negative of battery with metal.
• Never sheep or store battery together with metal.
• Never reverse two electrodes when use the battery.
• Never disassemble the battery without manufacturer's permission and guidance.
• Never knock, throw or trample the battery.
Tips!
• Keep the battery against high temperature. Otherwise it will cause battery heat, get into fire or lose some
function and reduce the life.
• When battery run out of power, please charge your battery timely (≤15 day).
• Please use the matched or suggested charger for this battery.
• If battery emit peculiar smell, heating, distortion or appear any abnormity during working or storage, please stop
using and take it out from device.
• If the battery leaks and get into the eyes or skin, do not wipe, instead, rinse it with clean water and see doctor
immediately.
• Please far away from children or pets.
• Do not put disuse battery into a fire or water.
• If user needs to parallel several battery packs, please charge them to full capacity with same type of matched
charger, and set it aside for 8 hours, professionals only. This battery pack supports application no more than
20 group parallel. If user needs to apply this product to more groups parallel, please reconfirm details with us.
• It is strictly prohibited any series between the battery packs. Any requirements on serials connection, please
contact UPOWER for details.
6. Storage & Transportation
• Based on the character of cell, proper environment for transportation of LiFePO4 battery pack need to be
created to protect the battery.
• Battery should be stayed in the warehouse -20ºC 〜35ºC where it’s dry, clean, shade and well-ventilated.
• The battery should be stored in 50% SOC during transportation.
• The battery need to be charged every 6 months if out of use.
• Keep the battery against dropping, turning over and serious stacking during loading.
7. Warning & Tips
UE-12Li60
01010105
www.upowerbatteries.com
66A Tzar Asen Srt.
Sofia, Republic of Bulgary
Tel. (+34) 918 021 649
Fax. (+34) 917 750 542
Table of contents
Other UPOWER Camera Accessories manuals
Popular Camera Accessories manuals by other brands

Viltrox
Viltrox EF-NEX Mount instructions

Calumet
Calumet 7100 Series CK7114 operating instructions

Ropox
Ropox 4Single Series User manual and installation instructions

Cambo
Cambo Wide DS Digital Series Main operating instructions

Samsung
Samsung SHG-120 Specification sheet

Ryobi
Ryobi BPL-1820 Owner's operating manual