Item
ChapterI Safety Information
Chapte II Brief Instroduction of the UTD1025CL Portable Digital Storage
Oscilloscope
UTD1025CL Oscilloscope Components
Features of UTD1025CL Oscilloscope
Chapter III Oscilloscope Connection
How to Conduct General Check
Check If Any Damage Resulted By Transportation
Check Accessory
Check the Complete Apparatus
Oscilloscope Connection
Compensation Signal Output Connection of the Apparatus
Oscilloscope panels and keys
Chapter IV Primary Application of Oscilloscope
Connect Appatatus to the Electricity Power
nterface Instruction
...............................
..............
............................................
...............................
.....................................
.......
.................................
.......................
.....................
.........................................
I.
Page
General safety Overview
.........................................
......................................................
.................................
4
.......................... 5
...........................
Preface
1
5
6
6
6
6
7
7
8
8
12
12
12
UTD1000L User Manual

Item
Oscilloscope Switch-In Probe Compensation Signal
Probe Compensation
Trigger Level
Munual Set Vertical System Horizontal System and Trigger Level,
Horizontal System
Automatic Setting of Waveform Display
Stop/Restore Data Collection
Trigger Frequency Count Setting
Screen Brightness Adjustment
Store Bitmap
Online Help
Set Single Trigger
Check Oscilloscope Status
.
.....................
..............................................
.
.................................
..............................
...............................
.................................................
..........................................
...................................
Page
.............
............................................
.........
...............................................
.....................................................
14
14
15
15
16
17
18
18
19
21
21
22
23
23
23
24
Operation Methods for Function Menu........................
Reset Oscilloscope
....................................
UTD1000L User Manual
Menu Hiding..............................................

Item
....................
............................................
............................................
.....................................
Automatic Parameter Measurement
Customization Parameter Measurement
Smooth Waveform by Average Treatment
Interface Indication Instruction
Multimeter Measurement
Measure Resistance Value
Measure Diode
Continuity Test
Measure Capacitance
Display Spike Pulse by the Peak Value Test Function
Use Persistence to Show Waveform
Select AC Coupling
Reverse Polarity of the Displayed Waveform
Automatic Setting for Small Signal with DC Bias
Connect Apparatus
Page
25
.............................
.........................
.................
..............................................
...................................
........................................
.......................................
........................
............
.............................
..............................................
.....................
Chapter V Use Multimeter...........................................
UTD1000L User Manual
Check Oscilloscope System Information
25
26
27
28
28
29
29
30
32
32
32
33
33
34
34
35

Item
Measure DC Current
Measure current
Hold Measurement Value
Relative Measurement
Select Automatic/Manual Range Adjustment
Chapter VI Details about Using Oscilloscope
Horizontal Sysmem Setting
AC
Vertical System Setting
Trigger System Setting
Collection Mode Setting
Display Set
Parameter Measurement Setting
Storage and Record
Record Function
Storage Function
..................
.......................................
..............................
Page
.............................................
..............................................
........................................
...........................................
............................
..........................................
......................................
...........................................
..................................................
.........................................
............................................. 65
.............................................68
.
36
36
37
39
41
41
42
43
43
46
49
57
58
60
65
Measure AC Voltage....................................
Measure DC Voltage...................................
UTD1000L User Manual

Item
Callback Function
Cursor Measurement
nterface Set
Auxiliary Function Set
Mathematic Operation Function
Automatic Set
Product Program Upgradation
Program Upgradation Conditions
Program Upgradation
Appendix A : Performance Index
Appendix B: Maintenance and Cleaning
............................................69
.........................................71
................................................
.......................................
...............................
...............................................
........................................
I
Preparations before Upgradation
............................
Page
...................................
...............................
..............................
......................
.
Chapter VII Troubleshooting.....................................
Chater VIII Service and Support......................................
Chapter IX Appendix............................................
UTD1000L User Manual
73
74
75
78
79
81
81
81
81
81
84
84
92

ChapterI Safety Information
Safety Terms and Symbol
Symbols on the product
Terms in the manual
Warning:
Notes:
Terms on the product
Danger:
Warning:
Notes:
The following terms might be in the manual:
warning statement indicates the
conditions and activities that might endander life
noting statement indicates the conditions and
activities that might cause damage to the product and
other property.
The following terms might be on the product:
it means reading the symbol might be
harmful to you immediately.
it means reading the symbol
it means damage might be caused to the
product or other property.
The following symbols might be on the product:
.
1
Please pay attention
to the Manual
High voltage Measurement of
the ground port
UTD1000L User Manual

General Safety Overview
The apparatus is strictly designed and produced
under the GB4793 Safety Requirements for
Electronic Measuring Apparatus and IEC61010-
1Safety Standard. The apparatus meets the over
voltage standard CAT V and safety
standards for pollution level II
Please read the following safety prevention
measures to prevent personal injury and any
damage to the product or other products connected
with the product. To avoid any possible danger, the
product shall be applicable in the stitulated
scope and be repaired by the specially trained
personnel.
To use the voltage probe, test lead wire and
adapter with certain insulation attached with the
oscilloscope or use the accessories designated by
UNI-T applicable to oscilloscope apparatus
series product.
Before using, check if any mechanic damage to
the multimeter test pen, oscilloscope probe and
accessories and please replace it if any damage
were found.
To remove all unused test pen, probe an
accessories.
To insert adapter into the AC socket and connect
it with the oscilloscope
In measurement in the CAT ambient don t
connect the voltage higher than 300V with the
oscilloscope input port and don t connect the
voltage higher than 600V with the multimeter input
port in the CAT ambient
Ⅲ 600
.
.
:
.
Ⅲ,'
'
Ⅲ.
Warning: to prevent electric shocking or fire,
please use the dedicated adapter approved to
apply in the country
Warning: if the oscilloscope input port were
connected with the voltage higher than 42 V 30
Vrms),to avoid electric shocking please
(
●
●
●
●
●
UTD1000L User Manual
2

UTD1000L User Manual
●
●
●
●
●
●
In measurement in the CAT ambient don t
connect the voltage with voltage difference higher
than 300V with the oscilloscope input port and
don t connect the voltage with voltage difference
higher than 600V with the multimeter input port in
the CAT ambient
Ⅲ,'
'
Ⅲ.
Don t use the input voltage higher than
apparatus rating value
Use accessories attached with the product and
cease using it if any damage to it.
Don t plug any metals into the socket.
Use the oscilloscope with the designated
method
The voltage rating value mentioned in the
Warning information is the limit value of adapter
Working Voltage they represent the Vrms 50-
60Hz ofACsinewaveinuse
to
avoid fire or electric shocking please pay
attention to all rating values and marks
Don t operate if there is any suspected trouble:
please let the qualified maitainence personnel to
check the product suspected being damaded
'
'
.
;(
).
.
':
,
.
'
.
'
'
Maintenance shall be conducted only by
qualified techinicians
Pay attention to all terminals rating value
Please don t operate in the moist anbient.
Please don t operate in the explosive anbient.
Keep product suface clean and dry.
3

UTD1000L User Manual
4
Chapte II Brief Instroduction
of the UTD1025CL Portable
Digital Storage Oscilloscope
Brief Instroduction of the UTD1025CL
Portable Digital Storage Oscilloscope
The UTD1025CL series of digital storage
oscilloscope referred hereinafter as
oscilloscope are a perfect combination of
usability, uniquie technical index and multipurpose,
helping users completing test more quickly.
The manual concludes the following types:
The UTD1025CL series of digital storage
oscilloscope provides a simple and functionally
clear front panel, enabling to conduct all basic
operations meeting the use habit of traditional
instrument and enabling the user to operate it
proficiently without taking much time to learn and
be familiar with operation of the digital storage
oscilloscope. In order to speed up the adjustment
for measuring, the user can press directly the
button AUTO , and then the instrument shall show
the proper waveform and the gear setting
Apart from the usability, UTD1025CL series of
digital storage oscilloscope possess high
efficiency index and powerful functions required
for quick measuring. To simplify the menu
operation, the combination operation of key
SHIFT on the apparatus and other keys can
enable direct operation of more functions
Besides, the powerful trigger and analysis ability
shall make it easier to capture and analyze the
waveform.The clear liquid crystal display and
(
)
,
.
.
Type Bandwidth Sampling
velocity
Channel
count
Single channel
UTD1025CL 25MHz 200MS/s
Table of contents
Other Unit Test Equipment manuals

Unit
Unit UTG1000X Series Owner's manual

Unit
Unit UTD1000 Series User manual

Unit
Unit UT677A User manual

Unit
Unit UT673A User manual

Unit
Unit UT522 User manual

Unit
Unit UTD2000M User manual

Unit
Unit MSO2000 Series User manual

Unit
Unit UTL8200 Series User manual

Unit
Unit UT3200+ Series User manual

Unit
Unit UT526 User manual