Topcon LS-B2 User manual

LS-B2 Operator’s Manual
W-1
Laser Systems, Inc. LS-B2
Laser Sensor

LS-B2 Operator’s Manual
W-1
Operators
Manual
W
arranty
TOPCON Laser Systems
Limited Warranty
TOPCON’s laser and machine control systems are warranted
against defective material and workmanship under normal use and
application for the time period specified on the Warranty Card
provided with the system.
The warranty against defects in any TOPCON battery, charger,
cable, valve, hose and mechanical part is 90 days.
During the warranty period, TOPCON will, at its option, repair or
replace the product at no additional charge. Repair parts and
replacement products will be furnished on an exchange basis and
will be either reconditioned or new. This limited warranty does not
include service to repair damage to the product resulting from
accident, disaster, misuse, abuse or modification of the product.
Calibration of components, labor and travel expenses incurred for
in-field removal and replacement of components are not covered
under this warranty.

LS-B2 Operator’s Manual
W-1
Warranty service may be obtained by contacting the TOPCON
dealer who made the original sale. Purchaser agrees to insure the
product or assume the risk of loss in transit, to prepay shipping
charges to the warranty service location and to use the original
shipping container or the equivalent. A letter should accompany the
package describing the problem and / or defect.

LS-B2 Operator’s Manual
W-1
Warranty Disclaimer
The above warranties are in lieu of all other warranties, whether
expressed or implied, including all warranties or merchantability, or
fitness for a particular purpose. In no event will TOPCON Laser
Systems, Inc.™ orits Representative be liable for lost profits or
other consequential damages arising from the purchase or use of
TOPCON Laser Systems, Inc.™ LS-B2 or any performance
hereunder or any claims of negligence, even if TOPCON Laser
Systems, Inc.™ has been advised of the possibility of such
damages.
Service assistance can be provided by contacting
your local TOPCON Laser Systems, Inc.™
dealer or by calling the Corporate Service Center.
Travel charges will be applied for any on-site
service whether warranty or non-warranty in nature.
Phone:(800)443-4567
8am to 5pm Pacific Time, Monday through Friday
FAX:(800)443-7503

LS-B2 Operator’s Manual
1
Contents
Nomenclature............................................................ 2
LS-B2 Nomenclature........................................... 2
RD-2 Nomenclature ............................................ 3
Installation................................................................. 4
Mounting the System.......................................... 4
Wiring the System............................................... 5
Maintaining Your System.................................... 6
Components.............................................................. 7
Operation.................................................................. 8
Operating the System........................................ 10
Grade Display Signals....................................... 14
Calibrating Valve Offsets................................... 16
Calibrating Valve Gain....................................... 18
Setting On Grade Precision............................... 20
LS-B2 Battery Pack................................................. 21

Nomenclature
LS-B2 Operator’s Manual
2
L
S-B2 Laser Sensor
Introduction
Thank you very much for purchasing this product from Topcon. In
order for it to serve you long and well, we ask that you read and
carefully follow the instructions contained in this manual. If you
have any questions, please contact your local authorized Topcon
dealer for assistance.
Topcon’s LS-B2 is a machine mounted laser sensor. Used in
conjunction with a rotating laser elevation reference, the LS-B2
helps operators get to grade quickly and accurately.
In manual control, the LS-B2 senses the position of a rotating laser
reference and flashes a clearly visible raise, lower, or on-grade
signal to the operator. The operator then corrects the position of the
cutting edge according to the signal. In automatic control, the LS-
B2 sends the signals directly to the machine’s hydraulics which
make the correction automatically.
The LS-B2 transfers easily from machine to machine and offers the
choice of on-board batteries or machine battery powered operation.
The LS-B2 has a unique infrared communication option called the
IR-2. The IR-2 receives an infrared signal from the LS-B2 and
transfers that signal to the RD-2 remote display mounted in the cab.
Used with the on-board battery pack, the infrared option removes
the need for cables between the LS-B2 and RD-2. This is an
advantage where routing cables from the sensor to the cab or from
the sensor to the battery is difficult and prone to accident.

Nomenclature
LS-B2 Operator’s Manual
3
Nomenclature
LS-B2 NOMENCLATURE
MOUNTING
KNOB
MOUNTING
BRACKET
PHOTO CELL
RECEIVING
WINDOW
POWER
BUTTON
ON
-
GRADE
PRECISION
OR “MODE”
BUTTON
“DEAD BAND”
PRECISION
INDICATORS
GRADE
INDICATE
LED’S
CABLE CONNECTOR
AND BATTERY PACK
CLAMP CONNECTORS
UNDERNEATH

Nomenclature
LS-B2 Operator’s Manual
4
RD-2 NOMENCLATURE
IR-2 CONNECTOR LOCATED ON
BACK OF RD-2
*Functions only when RD-2/LS-B2 are Cable Connected
“DEAD BAND”
PRECISION
INDICATORS
IR
-
2 MOUNTING
POSITION
POWER
ON/OFF
“DEAD BAND”
PRECISION
MODE*
CUTTING
EDGE LOWER
MODE
AUTO
CONTROL
MODE
GRADE
INDICATE
LED’S
MOUNTING
BRACKET
POWER
CONNECTOR
LS
-
B2
CONNECTOR
CUTTING
EDGE RAISE
MODE

Installation
LS-B2 Operator’s Manual
4
Installation
Mounting the System
Before installing your LS-B2 system, turn to page 7 to confirm that
you have received all system components. If you have not, contact
your local Topcon Laser Systems dealer for help.
The LS-B2 has been fitted with a clamp that attaches the unit to any
round pipe or pole 1.74" to 2.0" (44.45mm to 50.8mm) in diameter
or square pipes with sides from 1.5" to 1.95" (38.1mm to 50mm).
To Mount on a Machine Stick
To mount the LS-B2 on a backhoe or excavator, you must first have
a pipe attached to the machine stick. Weld two brackets to your
stick. Bolt or otherwise attach your mounting pipe to the brackets.
Then, clamp the LS-B2 onto the pipe.
To Mount LS-B2:
A: Close Bracket Over Pipe.
B:
Close Other Half of Bracket so
Threaded Shaft w/Centering Ball Sits
Firmly in Slot.
C: Turn Handle Until Tight.
Example
of Mounting Pipe
on Excavator or Backhoe Stick

Installation
LS-B2 Operator’s Manual
5
To Mount on a Blade or Screed
With pavers, motor graders, dozers, and scrapers, the LS-B2
attaches to a pole or mast that is mounted on the screed or blade.
Clamp the LS-B2 to the pole just as you clamp it to a pipe.
To Mount the RD-2 Remote Display
Using the head bolts and nuts supplied, mount the RD-2 to either a
vertical or horizontal surface in the cab.
MountingLS
-
B2
on a Motorgrader
Mounti
ngLS
-
B2
on an Asphalt Paver
ToMountLS
-
B2:
A: Close Bracket Over Pole or Mast.
B: Close Other Half of Bracket so Threaded
Shaft w/Centering Ball Sits Firmly in Slot.
C: Turn Handle Until Tight.
HORIZONTAL MOUNT
VERTICAL MOUNT
Table of contents
Other Topcon Accessories manuals

Topcon
Topcon RH-1 User manual

Topcon
Topcon LS-80A User manual

Topcon
Topcon LS-B100 User manual

Topcon
Topcon LS-B200 User manual

Topcon
Topcon LS-B4 User manual

Topcon
Topcon LS-B200W User manual

Topcon
Topcon LS-80A User manual

Topcon
Topcon LS-80A User manual

Topcon
Topcon LS-B10 User manual

Topcon
Topcon LS-B110 User manual