Time Machines 760-240-000 User manual

PoE Digital Clock
Installation and Operation Manual
* Legacy Edition *

Table of Contents
1. Introduction............................................................................................................................................1
2. Initial Setup............................................................................................................................................2
2.1 PoE..................................................................................................................................................2
2.2 Network...........................................................................................................................................2
2.3 Mounting.........................................................................................................................................2
2.3.1 Surface Mounting to Drywall..................................................................................................2
2.3.2 Rack Mounting........................................................................................................................3
2.3.3 Dual Clock Mount racket......................................................................................................3
3. Configuration.........................................................................................................................................5
3.1 Web Page – Default password is “tmachine”..................................................................................5
3.1.1 Network...................................................................................................................................7
3.1.2 Time Synchronization..............................................................................................................7
3.1.2.1 SNTP Servers...................................................................................................................7
3.1.2.2 Time Zone........................................................................................................................8
3.1.2.3 Custom Time Zone...........................................................................................................8
3.1.2.4 SNTP Resync Period........................................................................................................8
3.1.2.5 Twelve Hour Time...........................................................................................................8
3.1.3 Daylight Savings......................................................................................................................8
3.1.3.1 Daylight Savings(DST Options)......................................................................................8
3.1.3.2 Fixed Day.........................................................................................................................9
3.1.3.3 Start/Stop date..................................................................................................................9
3.1.3.4 Hour ias.........................................................................................................................9
3.1.4 Clock Type and Date Mode.....................................................................................................9
3.1.4.1 Use Calendar....................................................................................................................9
3.1.4.2 Date Mode........................................................................................................................9
3.1.4.3 Time.................................................................................................................................9
3.1.4.4 Date................................................................................................................................10
3.1.4.5 Date Offset.....................................................................................................................10
3.1.5 Other......................................................................................................................................10
3.1.5.1 Unit Name......................................................................................................................10
3.1.5.2 Password........................................................................................................................10
3.1.6 Alarms....................................................................................................................................10
3.1.6.1 External Connection.......................................................................................................11
3.1.7 rightness..............................................................................................................................12
3.2 Push utton...................................................................................................................................12
3.2.1 Changing the Time Zone.......................................................................................................12
3.2.2 Scrolling the IP address.........................................................................................................12
3.2.3 Set Parameters to Default......................................................................................................12
4. Troubleshooting...................................................................................................................................13
4.1 Flashing Seconds...........................................................................................................................13
4.1.1 Lost Link................................................................................................................................13
4.1.2 Missed NTP packet................................................................................................................13
4.2 AM/PM Sequence at oot Up.......................................................................................................13

Illustration Index
Illustration 1: Attaching Rack Mounting Ears...........................................................................................3
Illustration 2: 2.5" Dual Mount racket.....................................................................................................4
Illustration 3: Password Page.....................................................................................................................5
Illustration 4: Parameters Page (Part 1).....................................................................................................6
Illustration 5: Parameters Page (Part 2).....................................................................................................7
Illustration 6: Connector for Relay...........................................................................................................11
Illustration 7: Relay Connection Diagram..............................................................................................11
TimeMachines, Inc,
300 S 68th St Place, STE 100
Lincoln, NE 68510
Engineered and Manu actured in Lincoln, Ne, USA
402-486-0511
www.timemachinescorp.com.com
Form 1005A

1 Introduction
Time Machines Precision Clocks (TMPCs) provide an accurate synchronized time source when you
absolutely can't afford a time shift. TMPCs use Power over Ethernet (PoE) and Simple Network Time
Protocol (SNTP) to make installation and setup as clean and simple as possible. Connecting the clock
to a PoE enabled Local Area Network (LAN) Ethernet drop is all that needs to be done.
Clocks: Part Number
•Digital PoE Clock 2.5” x 4 Red Digits, lack Case 760-240-000
•Digital PoE Clock 2.5” x 6 Red Digits, lack Case 760-260-000
•Digital PoE Clock 2.5” x 4 Green Digits, lack Case 760-242-000
•Digital PoE Clock 2.5” x 6 Green Digits, lack Case 760-262-000
•Digital PoE Clock 4” x 4 Red Digits, lack Case 760-440-000
•Digital PoE Clock 4” x 6 Red Digits, lack Case 760-460-000
•Digital PoE Clock 4” x 4 Green Digits, lack Case 760-442-000
•Digital PoE Clock 4” x 6 Green Digits, lack Case 760-462-000
Optional Products:
Description Part Number
•Power over Ethernet Injector 760-200-000
•2.5” PoE Clock Rack Ear Set, lack 760-201-000
•2.5” Dual Mount racket 760-265-000
•4” 4-Digit Dual Mount racket 760-445-000
•4” 6-Digit Dual Mount racket 760-465-000
Installation and Operations Manual | Page 1
Web / timemachinescorp.com Email / [email protected] Phone / (402) 486.0511

2 Initial Setup
2.1 PoE
TMPCs require connection to a PoE enabled LAN. There are two ways of going about this, one is to
have a PoE switch and the other is to have a PoE injector. PoE injectors are offered through Time
Machines as an accessory.
2.2 Network
eyond connecting to a PoE enabled LAN, nothing else is required to get TMPCs up and running. IP,
Netmask, Gateway, and DNS addresses are all setup using Dynamic Hosting Configuration Protocol
(DHCP) by default. Static addresses may be assigned by accessing a configuration web page or by
using the clock's serial port. The default time server is set to nist1-chi.ustiming.org but can be changed
using the configuration web page. These processes are described with further detail in the
Configuration section.
2.3 Mounting
TMPCs may be surface mounted, rack mounted, or in a dual mount bracket (using two clocks).
Required tools: hammer, drill, 1/4” drill bit, screwdriver and pencil. Mounting options are optional.
2 3 1 Surface Mounting to Drywall
1. Use the provided template to mark the surface with the necessary hole positions for mounting.
(The template is located on the back side of the Quick Setup page included in the clock box.)
2. With a 1/4” drill bit, drill through the two marks.
3. Insert an anchor into each of the 2 holes using a hammer.
4. Insert a screw into each anchor leaving a 1/16-1/8 inch gap between the head of the screw and
the mounting surface.
5. Connect the network cable to the back of the clock.
6. Place the keyhole slots on the back of the clock over the screws and secure it into place.
Installation and Operations Manual | Page 2
Web / timemachinescorp.com Email / [email protected] Phone / (402) 486.0511

2 3 2 Rack Mounting
1. Attach an ear to each side of the clock.
2. Attach clock to rack.
2 3 3 Dual Clock Mount Bracket
Materials needed;
1. Two Time Machine Clocks of the same size
2. One Dual Mounting racket (760-265-000, 760-445-000 or 760-465-000)
3. 3/4” pipe, elbows, flange. Depending upon how you want to mount the clock determines what
pipe lengths and fittings you will need. The Dual Mounting racket accepts any 3/4” tubing
with NPT (National Pipe Threads) threads on the ends. This product is available through local
hardware stores or large national chain stores.
4. Ethernet cables long enough to run from the PoE injector or PoE router/switch to the clock
through the 3/4” pipe. When threading the cables through the pipe it is recommended that you
run both cables at the same time – one in front of the other.
How to mount two clocks in the Dual Mount racket:
1. Take two Time Machine clocks and match where the notch is on the display cover – this is
where the Ethernet cables will enter into the clock displays. The Dual Mount racket can be
placed on the bottom or on the top of the clocks. If needed, the display can be inverted so that
Installation and Operations Manual | Page 3
Web / timemachinescorp.com Email / [email protected] Phone / (402) 486.0511
Illustration 1: Attaching Rack Mounting Ears

the cables can run through the bracket and down into the backside of each clock.
2. At the ends of the clocks, leave the screws out about 1/4” so that they can be inserted into the
key holes on the Dual Mount racket.
3. EFORE you mount the clocks into the bracket, run two Ethernet cables through all pipe and
fittings that will be used to hang the clocks. Connect the cables to the clocks and then mount
the clocks into the bracket.
4. Secure the bracket to the clocks by tightening the screws on the ends of the bracket into the
clock.
5. egin to tighten the pipe into the bracket. Work from the pipe/Dual Clock racket connection
out to the connections for the wall or ceiling.
6. Secure the entire fixture to the wall or ceiling.
7. Connect the Ethernet cables to the PoE Source.
8. Power up the PoE injector.
Installation and Operations Manual | Page 4
Web / timemachinescorp.com Email / [email protected] Phone / (402) 486.0511
Illustration 2: 2.5" Dual Mount Bracket

3 Configuration
3.1 Web Page – Default password is “tma hine”
All TMPC parameters are accessed on the configuration web page. The page can be accessed by
pointing any web browser at the IP address of the TMPC. The initial IP address can be found by using
the push button (double-click) located on the back of the TMPC. After making changes to the
configuration page the “Save Settings” button must be pushed to submit form data. If the changes made
do not take effect, the “Restart” button must be pushed to restart the clock allowing changes to be
applied.
Installation and Operations Manual | Page 5
Web / timemachinescorp.com Email / [email protected] Phone / (402) 486.0511
Illustration 3: Password Page

Installation and Operations Manual | Page 6
Web / timemachinescorp.com Email / [email protected] Phone / (402) 486.0511
Illustration 4: Parameters Page (Part 1)

3 1 1 Network
y default the network parameters are setup up using DHCP. In order to set static values, uncheck the
DHCP check box and enter new values in the address fields. If the values aren't changed the current
addresses will be kept. The TMPC must be restarted for these changes to take affect. Addresses in
the Network section must be entered in Ipv4, dotted quad, format.
3 1 2 Time Synchronization
NOTE* If any timezone settings are changed, the changes will not take effect until the next SNTP
Resync Period.
3.1.2.1 SNTP Servers
The first entry (Primary SNTP Server) sets the address of the SNTP server, where where the TMPC
gets its timing information. In case the Primary SNTP Server is unreachable the TMPC will fall to the
ackup SNTP Server. oth DNS names (time.nist.gov) and IPv4 (192.43.244.18) formats are accepted.
3.1.2.2 Time Zone
Selecting the Time Zone sets the offset the clock will display from Greenwich Mean Time. All fields
Installation and Operations Manual | Page 7
Web / timemachinescorp.com Email / [email protected] Phone / (402) 486.0511
Illustration 5: Parameters Page (Part 2)
This manual suits for next models
11
Table of contents
Other Time Machines Clock manuals
Popular Clock manuals by other brands
Silicon Laboratories
Silicon Laboratories SI5324 manual

Heathkit
Heathkit GC-1005 Assembly manual

Oregon Scientific
Oregon Scientific PRYSMA RMR221P manual

Andrew O'Malley
Andrew O'Malley DOTKLOK Assembly instructions

ALGE-Timing
ALGE-Timing ASC3 manual

Bodet
Bodet Profil 960 Installation and operating instructions

Progetti
Progetti KALIMERO Directions

La Crosse Technology
La Crosse Technology WT-3141b Quick setup instructions

La Crosse Technology
La Crosse Technology W86531 owner's manual

Sharp
Sharp SPC900 instruction manual

La Crosse Technology
La Crosse Technology 404-50447 quick start guide

Datexx
Datexx DF0063 quick guide