Theben 850 9 133 User manual

Installation and
operating instructions
OT remote control
for ventilation
850 9 133
309 362 03
Remote control
D F GB
GB

Contents
Basic safety instructions 3
Screen and push buttons 4
Connection/installation/dismantling 6
Reset 7
Info button i 7
Factory setting 8
Initial start-up 9
User operating level 10
Setting programs 10
Switch system off 10
Changing operating settings 10
Setting REDUCED program 10
Setting NORMAL program 11
Setting PARTY program 11
Setting program P1 12
Setting program P2 12
Setting switching times 13
Delete all switching times 17
Viewing switching times 17
Reducing ventilation for several days 18
Setting the holiday program 18
Ending/deleting holiday program 19
Viewing Holiday program 19
Changing ventilation manually 20
Operating level for
specialist personnel 21
Settings - Overview 21
Setting bypass functions 22
Setting date and time 22
Service setting 24
Setting display type 24
Setting the language 25
Setting parameters 26
Technical details/Service address 29
2

Basic safety instructions
• The remote control is designed for wall installation
Designated use
•
The remote control device controls ventilation in detached and multi-occupancy houses, flats, offices etc.
• There is a choice of 2 time programs for automatically switching between reduced mode and
normal mode
Various parameters can be set on the remote control (see page 28 ff.)
• It is used in dry rooms with normal levels of domestic cleanliness
Disposal
Dispose of device in environmentally sound manner
Danger of death through electric shock or fire!
Installation should only be carried out by a qualified electrician!
WARNING
3
GB

Screen and push buttons
1 Day of the week display (1 = Monday ...)
2 +/– (change values)
3 Rotary switch for program selection
4 OK (confirm selection, call up next parameter)
5 ESC (escape, cancel entry)
6 info (view settings)
7 RES (Reset for time, date, holiday program)
8 Fan operating display
9 Additional on-screen displays
i
RES
P2
P1
12 3 4 5 6 7
OK
ESC
MENU g
m
r
1 2 3
456789
4

Screen and buttons (ff.)
1 Weekdays 1 to 7
2 Display menu line
Bypass function
Date and time
PROG individual time program P2
Holiday program
Service settings
3 Display text line
Display depending on menu level and
display settings
4 Fan operating display
5 Display dependent on types of display
Type 1 room temperature
Type 2 time (delivered status)
6 Ventilation time of time program
12
9
630 15 1
821 24h
12 3 4 5 6 71
2
3
4
65
5
GB

Connection/installation
OpenTherm (2-wire cable, 2 x 0.75 mm2)
6
OT bus
Installation
Fix plate to wall and attach device.
Ensure installation height of approx. 1.5 m.
Avoid installation near tiled stoves, windows, display cases, television sets etc.
Dismantling
Insert screwdriver from below, push detent hooks up and open device.
OT bus

Reset
Press the RES button with a sharp object.
The following data is deleted: Date, time and
holiday program.
Summer/winter changeover and program P2
remain unchanged.
Info key i – View settings
The info button can be used to view the current room temperature,
all important settings of the relevant program, date and
time as well as some current data from ventilation device
(the rotary switch must not point to MENU).
Press i button several times to view the current data:
– Room temperature (only with display type 1, see page 24)
– Date and time
– Bypass valve position
– Current air flow
– Discharged air temperature
7
GB

Factory setting (delivery status)
Press ESC and OK buttons simultaneously for approx. 2 s.
Select + or – buttons for value 1 (reset to factory setting) or
value 0 (no reset).
Confirm by pressing OK.
If value 1 is confirmed, the following data will be deleted:
Holiday program, time, date, program 2 and the GERMAN language option.
Factory setting (delivery status - configuration)
Set rotary switch to MENU.
Select SERVICE using the + or – buttons. Symbol flashes.
Confirm by pressing OK. DISPLAY flashes.
Select PARAMETER using the + or – buttons.
Select parameter 22 by pressing OK.
Use + or – buttons to select desired change 1 (= yes) or 0 (= no).
Confirm by pressing OK (all parameters are on factory setting, see page 28).
Set rotary switch to desired program.
MENU
8

Initial start-up
After connecting the OpenTherm bus line,
follow instructions on display.
Setting date and time
The time appears first on the display at initial
start-up or after a reset.
Use the + or – buttons to select the HOUR,
MINUTE, YEAR, MONTH and DAY.
Confirm by pressing OK.
Use the + or – buttons to select END or
for the summer/winter time changeover
WITHOUT SU/WI or WITH SU/WI.
Confirm by pressing OK.
If you select WITH SU/WI you can choose
between EUROPE, FREE SETTING and different
countries.
Confirm each setting by pressing OK.
Set rotary switch to desired program.
The date, time and summer/winter changeover
can also be set in the SERVICE menu under
HOUR/DATE (see page 23 ff.).
Select language in the SERVICE menu
(see page 26 ff.).
9
GB

Setting programs
Switch system off
Set rotary switch to – You can briefly
switch the system off.
Changing operating settings
Set rotary switch to MENU, e.g. for
changes to program P2.
Setting REDUCED program
Set rotary switch to REDUCED .
The air will be changed once within
approx. 3 hours (e.g. at night or if
occupant is away)
& user information
Caution:
If the system is switched off
damage could be caused by
moisture.
Therefore, select REDUCED if
away for a long period.