Tektronix THDP0100 User manual

Copyright © Tektronix. All rights reserved. Licensed software products are owned by Tektronix or its subsidiaries or suppliers, and are
protected by national copyright laws and international treaty provisions. Tektronix products are covered by U.S. and foreign patents, issued
and pending. Information in this publication supersedes that in all previously published material. Specifications and price change privileges
reserved.
TEKTRONIX and TEK are registered trademarks of Tektronix, Inc.
Contacting Tektronix
Tektronix, Inc.
14150 SW Karl Braun Drive
P.O. Box 500
Beaverton, OR 97077
USA
For product information, sales, service, and technical support:
• In North America, call 1-800-833-9200.
• Worldwide, visit to www.tek.com find contacts in your area.

Contents
Important safety information..........................................................................................................................................................5
General safety summary........................................................................................................................................................5
To avoid fire or personal injury........................................................................................................................................5
Probes and test leads..................................................................................................................................................... 6
Service safety summary.........................................................................................................................................................7
Terms in this manual.............................................................................................................................................................. 8
Terms on the product............................................................................................................................................................. 8
Symbols on the product......................................................................................................................................................... 8
Compliance information................................................................................................................................................................ 9
Safety compliance..................................................................................................................................................................9
Environmental compliance...................................................................................................................................................10
Overview......................................................................................................................................................................................11
Probe operating information........................................................................................................................................................14
Connecting to the instrument............................................................................................................................................... 14
Connecting to the circuit...................................................................................................................................................... 15
Probe controls and indicators.............................................................................................................................................. 15
Functional check.................................................................................................................................................................. 19
AutoZero....................................................................................................................................................................... 20
DC offset zero...............................................................................................................................................................20
DC offset zero reset......................................................................................................................................................21
Accessories and options............................................................................................................................................................. 22
THDP0100 probe standard accessories.............................................................................................................................. 22
THDP0200 and TMDP0200 probe standard accessories....................................................................................................26
THDP and TMDP Series probes optional accessories........................................................................................................ 33
Service Options....................................................................................................................................................................34
Operating basics......................................................................................................................................................................... 35
Operating limits.................................................................................................................................................................... 35
Measurement examples.......................................................................................................................................................36
Overrange detection............................................................................................................................................................ 37
Common-mode rejection......................................................................................................................................................38
Twisting the input leads........................................................................................................................................................38
Probe Loading......................................................................................................................................................................38
Specifications.............................................................................................................................................................................. 39
Warranted specifications......................................................................................................................................................39
Typical characteristics..........................................................................................................................................................40
Mechanical characteristics...................................................................................................................................................41
Nominal characteristics........................................................................................................................................................41
Performance graphs............................................................................................................................................................ 42
Performance verification............................................................................................................................................................. 46
Required equipment.............................................................................................................................................................46
TekVPI Calibration Fixture ........................................................................................................................................... 47
Test procedures................................................................................................................................................................... 47
DC gain Accuracy......................................................................................................................................................... 48
Rise time.......................................................................................................................................................................49
Contents
High Voltage Differential Probes THDP0100/0200 and TMDP0200 User Manual 3

Test record........................................................................................................................................................................... 50
Adjustments................................................................................................................................................................................ 51
Equipment required .............................................................................................................................................................52
Adjustment procedures........................................................................................................................................................ 53
Offset zero.................................................................................................................................................................... 54
Gain accuracy...............................................................................................................................................................56
DC CMRR.....................................................................................................................................................................57
LF compensation.......................................................................................................................................................... 58
AC CMRR..................................................................................................................................................................... 59
Maintenance................................................................................................................................................................................61
Host instrument firmware..................................................................................................................................................... 61
Error conditions ...................................................................................................................................................................61
Cleaning...............................................................................................................................................................................61
Service................................................................................................................................................................................. 62
Contents
4

Important safety information
This manual contains information and warnings that must be followed by the user for safe operation and to keep the product in a safe
condition.
To safely perform service on this product, see the Service safety summary that follows the General safety summary.
General safety summary
Use the product only as specified. Review the following safety precautions to avoid injury and prevent damage to this product or any
products connected to it. Carefully read all instructions. Retain these instructions for future reference.
This product shall be used in accordance with local and national codes.
For correct and safe operation of the product, it is essential that you follow generally accepted safety procedures in addition to the safety
precautions specified in this manual.
The product is designed to be used by trained personnel only.
Only qualified personnel who are aware of the hazards involved should remove the cover for repair, maintenance, or adjustment.
Before use, always check the product with a known source to be sure it is operating correctly.
This product is not intended for detection of hazardous voltages.
Use personal protective equipment to prevent shock and arc blast injury where hazardous live conductors are exposed.
While using this product, you may need to access other parts of a larger system. Read the safety sections of the other component manuals
for warnings and cautions related to operating the system.
When incorporating this equipment into a system, the safety of that system is the responsibility of the assembler of the system.
To avoid fire or personal injury
Connect and disconnect properly
Do not connect or disconnect probes or test leads while they are connected to a voltage source.
Use only insulated voltage probes, test leads, and adapters supplied with the product, or indicated by Tektronix to be suitable for the
product.
Observe all terminal ratings
To avoid fire or shock hazard, observe all rating and markings on the product. Consult the product manual for further ratings information
before making connections to the product.
Do not exceed the Measurement Category (CAT) rating and voltage or current rating of the lowest rated individual component of a product,
probe, or accessory. Use caution when using 1:1 test leads because the probe tip voltage is directly transmitted to the product.
Do not apply a potential to any terminal, including the common terminal, that exceeds the maximum rating of that terminal.
Do not operate without covers
Do not operate this product with covers or panels removed, or with the case open. Hazardous voltage exposure is possible.
Avoid exposed circuitry
Do not touch exposed connections and components when power is present.
Important safety information
High Voltage Differential Probes THDP0100/0200 and TMDP0200 User Manual 5

Do not operate with suspected failures
If you suspect that there is damage to this product, have it inspected by qualified service personnel.
Disable the product if it is damaged. Do not use the product if it is damaged or operates incorrectly. If in doubt about safety of the product,
turn it off and disconnect the power cord. Clearly mark the product to prevent its further operation.
Before use, inspect voltage probes, test leads, and accessories for mechanical damage and replace when damaged. Do not use probes or
test leads if they are damaged, if there is exposed metal, or if a wear indicator shows.
Examine the exterior of the product before you use it. Look for cracks or missing pieces.
Use only specified replacement parts.
Do not operate in wet/damp conditions
Be aware that condensation may occur if a unit is moved from a cold to a warm environment.
Do not operate in an explosive atmosphere
Keep product surfaces clean and dry
Remove the input signals before you clean the product.
Probes and test leads
Before connecting probes or test leads, connect the power cord from the power connector to a properly grounded power outlet.
Keep fingers behind the protective barrier, protective finger guard, or tactile indicator on the probes. Remove all probes, test leads and
accessories that are not in use.
Use only correct Measurement Category (CAT), voltage, temperature, altitude, and amperage rated probes, test leads, and adapters for
any measurement.
Beware of high voltages
Understand the voltage ratings for the probe you are using and do not exceed those ratings. It is important to know and understand he
maximum measurement voltage from the probe tip to the probe reference lead.
The voltage rating depends on the probe and your application. Refer to the Specifications section of the manual for more information.
WARNING: To prevent electrical shock, do not exceed the maximum measurement or maximum floating voltage for the
oscilloscope input BNC connector, probe tip, or probe reference lead.
WARNING: To prevent damage to the alligator clip insulation, do not use in high A/m magnetic fields at high frequencies, which
can cause induction heating of the jaws.
Connect and disconnect properly.
Connect the probe output to the measurement product before connecting the probe to the circuit under test. Connect the probe reference
lead to the circuit under test before connecting the probe input. Disconnect the probe input and the probe reference lead from the circuit
under test before disconnecting the probe from the measurement product.
Inspect the probe and accessories
Before each use, inspect probe and accessories for damage (cuts, tears, or defects in the probe body, accessories, or cable jacket). Do
not use if damaged.
Important safety information
6

Service safety summary
The Service safety summary section contains additional information required to safely perform service on the product. Only qualified
personnel should perform service procedures. Read this Service safety summary and the General safety summary before performing any
service procedures.
To avoid electric shock
Do not touch exposed connections.
Do not service alone
Do not perform internal service or adjustments of this product unless another person capable of rendering first aid and resuscitation is
present.
Disconnect power
To avoid electric shock, switch off the product power and disconnect the power cord from the mains power before removing any covers or
panels, or opening the case for servicing.
Use care when servicing with power on
Dangerous voltages or currents may exist in this product. Disconnect power, remove battery (if applicable), and disconnect test leads
before removing protective panels, soldering, or replacing components.
Verify safety after repair
Always recheck ground continuity and mains dielectric strength after performing a repair.
Important safety information
High Voltage Differential Probes THDP0100/0200 and TMDP0200 User Manual 7

Terms in this manual
These terms may appear in this manual:
WARNING: Warning statements identify conditions or practices that could result in injury or loss of life.
CAUTION: Caution statements identify conditions or practices that could result in damage to this product or other property.
Terms on the product
These terms may appear on the product:
•DANGER indicates an injury hazard immediately accessible as you read the marking.
• WARNING indicates an injury hazard not immediately accessible as you read the marking.
• CAUTION indicates a hazard to property including the product.
Symbols on the product
When this symbol is marked on the product, be sure to consult the manual to find out the nature of the potential
hazards and any actions which have to be taken to avoid them. (This symbol may also be used to refer the user to
ratings in the manual.)
The following symbols(s) may appear on the product.
CAUTION: Refer to
Manual
Earth Terminal WARNING: High
Voltage
Important safety information
8

Compliance information
This section lists the safety and environmental standards with which the instrument complies. This product is intended for use by
professionals and trained personnel only; it is not designed for use in households or by children.
Compliance questions may be directed to the following address:
Tektronix, Inc.
PO Box 500, MS 19-045
Beaverton, OR 97077, USA
tek.com
Safety compliance
This section lists the safety standards with which the product complies and other safety compliance information.
EU declaration of conformity – low voltage
Compliance was demonstrated to the following specification as listed in the Official Journal of the European Union:
Low Voltage Directive 2014/35/EU.
• EN 61010-031. Particular requirements for handheld probe assemblies for electrical measurement and test equipment
U.S. nationally recognized testing laboratory listing
• UL 61010-031. Particular requirements for handheld probe assemblies for electrical measurement and test equipment
Canadian certification
• CAN/CSA-C22.2 No. 61010-031. Particular requirements for handheld probe assemblies for electrical measurement and test
equipment
Additional compliances
• IEC 61010-031. Particular requirements for handheld probe assemblies for electrical measurement and test equipment
Equipment type
Test and measuring equipment.
Pollution degree rating
Pollution degree 2 (as defined in IEC 61010-1). Rated for indoor, dry location use only.
IP rating
IP20 (as defined in IEC 60529).
Measurement and overvoltage category descriptions
Measurement terminals on this product may be rated for measuring mains voltages from one or more of the following categories (see
specific ratings marked on the product and in the manual).
• Overvoltage Category I. For equipment intended to be connected to a mains supply in which means have been taken to substantially
and reliably reduce transient overvoltages to a level where they cannot cause a hazard.
Compliance information
High Voltage Differential Probes THDP0100/0200 and TMDP0200 User Manual 9

• Measurement Category II. For measurements performed on circuits directly connected to the low-voltage installation.
•Measurement Category III. For measurements performed in the building installation.
• Measurement Category IV. For measurements performed at the source of low-voltage installation.
Note: Only mains power supply circuits have an overvoltage category rating. Only measurement circuits have a measurement
category rating. Other circuits within the product do not have either rating.
Mains overvoltage category rating
Overvoltage category II (as defined in IEC 61010-1).
Environmental compliance
This section provides information about the environmental impact of the product.
Product end-of-life handling
Observe the following guidelines when recycling an instrument or component:
Equipment recycling Production of this equipment required the extraction and use of natural resources. The equipment may
contain substances that could be harmful to the environment or human health if improperly handled at the
product’s end of life. To avoid release of such substances into the environment and to reduce the use of
natural resources, we encourage you to recycle this product in an appropriate system that will ensure that
most of the materials are reused or recycled appropriately.
This symbol indicates that this product complies with the applicable European Union requirements according to Directives
2012/19/EU and 2006/66/EC on waste electrical and electronic equipment (WEEE) and batteries. For information about
recycling options, check the Tektronix Web site (www.tek.com/productrecycling).
Compliance information
10
Other manuals for THDP0100
2
This manual suits for next models
2
Table of contents
Other Tektronix Accessories manuals

Tektronix
Tektronix CT-6 User manual

Tektronix
Tektronix P7225 User manual

Tektronix
Tektronix GeoProbe G10 Owner's manual

Tektronix
Tektronix P6249 User manual

Tektronix
Tektronix P5200A User manual

Tektronix
Tektronix TMSSY2 mPGA479 User manual

Tektronix
Tektronix TPP0500 User manual

Tektronix
Tektronix TriMode P7500 Series Manual

Tektronix
Tektronix TPP1000 User manual

Tektronix
Tektronix P5122 User manual