TECE RDB 742X2-00 User manual

DAN
NOR
FIN
SWE
POL
ENG
RUS
RDB 742X2-00
129019.1724

2
DAN
NOR
FIN
SWE
POL
ENG
RUS
7
3
24
40
56
72
ENG
DAN NOR
FIN
SWE
POL
88
RUS

3
DAN
NOR
FIN
SWE
POL
ENG
RUS
Warning
Danger to life in case of swallowing
Small children might swallow the knob.
¾Install the room control unit outside the reach of little
children.
Advarsel
Livsfare pga. slugning
Små børn kan sluge drejeknappen.
¾Rumbetjeningsenheden skal monteres uden for småbørns
rækkevidde.
Varoitus
Nieleminen voi aiheuttaa hengenvaaran
Pikkulapset voivat nielaista säätönapin.
¾Huoneyksikkö on asennettava lasten ulottumattomiin.
Varning
Livsfara genom nedsväljning
Småbarn kan svälja vreden.
¾Montera rumskontrollen utom räckhåll för småbarn.
Ostrzeżenie
Zagrożenie dla życia w przypadku połknięcia
Małe dzieci mogą połknąć pokrętło.
¾Urządzenie do obsługi montować poza zasięgiem małych
dzieci.
Предупреждение
Опасность для жизни при проглатывании
Дети могут проглотить кнопку настройки
¾Монтировать RBG вне досягаемости детей.

4
DAN
NOR
FIN
SWE
POL
ENG
RUS
~150 cm
~ 30 cm
(RDB 74212-00)
1 x 1 x
(RDB 74212-00)
*
* optional / som option / lisävarusteinen / tillval / w opcji / опция

5
DAN
NOR
FIN
SWE
POL
ENG
RUS

6
DAN
NOR
FIN
SWE
POL
ENG
RUS
2
4
6
1 3
Ø3,5 mm RDB 74212-00
5b
5a
1234
Power
rmBUS
Error
syBUS
Fuse Pump Boiler Cool
H% Master NO
Pairing

7
DAN
NOR
FIN
SWE
POL
ENG
RUS
Content
1 Safety............................................................................................8
Used signal words and notes ...................................................8
Intended use .............................................................................8
General safety notes.................................................................8
2 Versions ........................................................................................9
Technical data ...........................................................................9
Conformity ................................................................................9
3 Operation ...................................................................................10
Overview and display .............................................................10
Operation................................................................................11
Connection test.......................................................................11
Commissioning (incl. pairing).................................................12
Comfort programs - Smart Start/Stop mode.........................12
Lifestyle functions overview...................................................13
Lifestyle functions...................................................................14
Overview parameter...............................................................17
Parameter................................................................................18
4 Cleaning and Troubleshooting..................................................22
Troubleshooting......................................................................22
Cleaning ..................................................................................23
5 Decommissioning.......................................................................23
Disposal ...................................................................................23
ENG

8
DAN
NOR
FIN
SWE
POL
ENG
RUS
Used signal words and notes
Intended use
General safety notes
The room control unit BUS with display (in the following ab-
breviated as RBG) is the operating unit for the base station
BUS 24 V & 230 V BSB x0xx2-xx. The unit serves for
9for the control of the base stations BUS of the type BSB
x0xx2-xx.
9the registration of the room temperature and the setting
of the desired target temperature in the allocated heating
zone.
Every other use is considered as not intended; the manufacturer
cannot be held liable for this.
1 Safety
The following symbols show you, that
¾you must do something
9a precondition must be met
Warning
there is danger for life and limb.
Warning
Danger to life in case of swallowing
Small children might swallow the knob.
¾Install the room control unit outside the reach of little child-
ren.
¾Retain this manual and provide it to future owners.

9
DAN
NOR
FIN
SWE
POL
ENG
RUS
Technical data
2 Versions
Conformity
This product is labelled with the CE Marking and thus is in com-
pliance with the requirements from the guidelines:
92014/30/EU with amendments “Council for Coordination of
the Regulations of EU Member Countries regarding Electro-
magnetic Compatibility”
92014/35/EU with amendments “Council for Coordination
of the Regulations of EU Member Countries regarding the
electrical equipment for use within certain voltage limits”
Increased protection requirements may exist for the overall
installation, the compliance of which is the responsibility of the
installer.
RDB 74202-00 RDB 74212-00
Floor temperature moni-
toring – Remote sensor
Voltage supply 24 … 35 V [via rmBUS]
BUS connection [rmBUS] polarity reversal-protected
Protection type/protection
class IP20 / III
Ambient temperature 0 to 50°C
Ambient humidity 5 to 80 %, not condensing
Dimensions (HxWxD): 86 x 86 x 26.5 mm
Target temp. setting range 5 to 30°C
Target temp. resolution 0.2 K
Actual temp. measuring
range 0 to 40°C (int. sensor)
Measuring accuracy of
internal NTC ±0.3 K

10
DAN
NOR
FIN
SWE
POL
ENG
RUS
Overview and display
3 Operation
Display with function indications
Room temperature
Time
Rotary Control
Symbol Meaning Symbol Meaning
Menu “Functions”
active Night mode active
Menu “Param-
eters” active
Bedewing
detected, cooling
mode deactivated
Menü „Service“
aktiv Cooling mode active
Important note/
malfunction
Flashing: Smart
Start/Stop mode
active
Lighting up: Heat-
ing mode active
Child safety lock
active
Presence active
(only in Automatic
mode)
Stand-by mode
active Party function active
Automatic mode
active
Holiday function
Flashing: planned
Lighting up: active
Day mode active
Minimum oor
temperature fallen
short of
Table of contents
Languages:
Other TECE Thermostat manuals
Popular Thermostat manuals by other brands

Saswell
Saswell SAS920XWHB-7-S-RF User manual and warranty card

Aircalo
Aircalo TFP1-ET85P2 operating manual

Honeywell
Honeywell CM721 user manual

Carrier
Carrier DEBONAIR 33CS Installation and operating instructions

Lennox
Lennox iHarmony Zone Thermostat Installation and setup guide

Gemtech
Gemtech GT7000 Operation













