T&D RTR-50 User manual

2007.03 16004474040
#OMMUNICATION0ORT
7IRELESS
242
© Copyright 2007 T&D Corporation. All rights reserved.

i
Notices
Carefully read this manual so that you can properly use this product.
T&D Corporation accepts no responsibility for any malfunction of and/or trouble with
this product or with your computer that is caused by the improper handling of this
product and will deem such trouble or malfunction as falling outside the conditions for
free repair of the attached warranty.
ȆAll rights of this User's Manual belong to T&D Corporation. It is prohibited to use,
duplicate and/or arrange a part or whole of this User's Manual without the
permission of T&D Corporation.
ȆMicrosoft®and Windows®are registered trademarks of Microsoft Corporation USA
and are binding in the USA and all other countries.
ȆCompany names and product names are trademarks or registered trademarks of
each company.
ȆSpecifications, design and other contents are subject to change without notice.
ȆOn screen messages in this manual may vary slightly from the actual messages.
ȆPlease notify the shop where you purchased this product or T&D Corporation of
any mistakes, errors or unclear explanations in this manual. T&D Corporation
accepts no responsibility for any damage or loss of income caused by the use of
our product.
ȆThis product has been designed for private or industrial use only. It is not for use in
situations where strict safety precautions are necessary such as in connection with
medical equipment, whether directly or indirectly.
ȆWe are not responsible for any malfunction or trouble caused by the use of our
product or by any problem caused by the use of measurement results of our unit.
Please be fully aware of this before using our product.
ȆSome of our products, which come under the category of strategic goods in foreign
trade law, need the permission of the Japanese government to be exported outside
of Japan.
ȆThe Manual itself can be downloaded from our Home Page: http://www.tandd.com/

ii
Introduction
Software User Agreement
Escape Clauses
ȆT&D Corporation does not guarantee the operation of RTR-50 for Windows®.
ȆT&D Corporation shall not accept any responsibility for any damage, whether direct or
indirect, that results from the usage of T&D Recorder for Windows.
ȆSpecifications of RTR-50 for Windows®may be subject to change and service may be
terminated without advance notice to the user. In such a case, T&D Corporation shall
not be responsible for any damages, whether direct or indirect, from the inability to
use RTR-50 for Windows®.
ȆT&D Corporation has no obligation to correct any defects found in RTR-50 for
Windows.
Copyright
ȆThe Copyright for RTR-50 for Windows®, including the program and relevant
documents, belongs solely to T&D Corporation.
ȆThe reprinting or redistribution for commercial purposes whether in part or in whole, in
magazines or as a part of any product is strictly forbidden without the expressed
consent of T&D Corporation. Any inquires concerning commercial redistribution
should be directed to the Sales Department of T&D Corporation.
ȆPlease do not attempt to make any changes or modifications to RTR-50 for Windows®.

iii
Table of Contents
Software User Agreement------------------- ii
Escape Clauses ---------------------------------- ii
Copyright ------------------------------------------- ii
Safety Precautions and Instructions ------v
To ensure safety be sure to obey all of the
following warnings.-------------------------------v
1. Introduction
What is Wireless Communication Port
RTR-50? -----------------------------------------3
Application Examples ---------------------------3
What is RTR-50 for Windows®? ------------4
Outline ----------------------------------------------4
Basic Functions ----------------------------------4
Package Contents -----------------------------6
Part Names and Functions------------------7
Appearance Diagram ---------------------------7
2. Getting Ready
General Procedure ----------------------------9
Getting Ready -------------------------------- 10
Install Batteries --------------------------------- 10
Install RTR-50 for Windows®-------------- 11
Connect the RTR-50 with a USB
communication cable to your computer 12
Installing the USB Device Driver--------- 13
Confirming the USB Device Driver
Connection to the Computer-------------- 18
Windows®XP / 2000 --------------------------18
Windows® Me/98SE ---------------------------19
If USB Device Driver Installation Fails-- 20
How to Re-install -------------------------------20
Connecting the RTR-50 with a serial
communication cable to your computer 21
Setting up the Communication Port ----- 22
3.
How to use "RTR-50 for Windows"
Basic Functions ------------------------------ 25
Open "RTR-50 for Windows"----------------25
Explanation of Display ------------------------ 25
Main Unit Info -----------------------------------27
Remote Unit / Relay Unit Registration-- 28
Basic Procedure for Registration----------- 28
Registering a Remote Unit ------------------31
Deletion and Initialization of Remote
Unit ------------------------------------------------33
Getting Remote Unit Current Status
(Wireless Communication)-------------------35
Getting Registration Info
(Optical Communication)--------------------- 36
Registering a Relay Unit ---------------------37
Connect a Remote Unit via Relay Unit ---39
Deletion and Initialization of Relay Unit -- 40
Getting Relay Unit Current Status
(Wireless Communication)-------------------42
Getting Base Unit / Relay Unit Info
(Direct Communication) ----------------------43
Wireless Communication Test -------------- 44
Data Download Settings ------------------- 46
[Detailed Settings] Button-------------------- 48
Recording Start Settings------------------- 50
When using Wireless Communication ----50
When using Optical Communication ------ 53
Monitoring / Warning Monitoring
Settings----------------------------------------- 56
[Monitoring Settings] -------------------------- 56
[Monitoring Interval] Button------------------57
[Warning Settings] ----------------------------57
[Warning Report Mail Settings] Button --- 57
[View Warning Log] Button ------------------ 58
[Start Monitoring / Warning Monitoring]
Button ---------------------------------------------59
Monitoring Graph Window ------------------- 59
Monitoring Graph Settings------------------- 60
Mail Settings-------------------------------------63

iv
Getting Ready RTR-50 for Windows Graph Other
Introduction
Auto-Download Settings ------------------- 64
[Auto-Download Settings] -------------------- 64
[Start Auto-Download] Button--------------- 65
[Data Storage Folder] Button---------------- 65
[View Auto-Download Log] Button ---------66
4. Graph Operations
Temperature / Humidity Graph ----------- 69
Main Window Names and Functions------69
Zooming In and Out on the Graph--------- 71
[Graph] Menu -----------------------------------72
Data List Display -------------------------------73
Switching the Graph Display Mode--------74
High, Low, Avg. Calculation Range-------- 75
Editing Recording Conditions --------------- 76
Re-ordering Channel Data------------------- 77
Erasing Selected Channel Data------------ 78
Changing Graph Colors and
Widths of Lines --------------------------------- 79
Shift Unit (Ɏ/ ɋF) ------------------------------80
Copy Display to Clipboard ------------------- 80
Print Preview and Print -----------------------80
Multi-scale Graph ---------------------------- 82
Main Window Names and Functions------83
Zooming In and Out on the Graph--------- 85
Data List Display -------------------------------86
Changing Graph Display Mode-------------87
High, Low, Avg. Calculation Range-------- 87
Editing Recording Conditions --------------- 87
Re-ordering Channel Data------------------- 87
Erasing Selected Channel Data------------ 88
Merging Channel Data------------------------ 88
Setting Vertical Axis Display Range ------- 89
Scale / Unit Conversion ---------------------- 90
Changing Graph Colors and
Widths of Lines --------------------------------- 91
Print Preview and Print -----------------------93
Event Viewer ---------------------------------- 94
Main Window Names and Functions------95
Changing the Event Viewer Method of
Display -------------------------------------------- 96
File Info -------------------------------------------97
Open multiple sets of data------------------- 97
Print Preview and Print -----------------------98
Other Functions ------------------------------ 99
Saving Recorded Data------------------------99
Saving Data for Event Viewer --------------- 99
Saving Data as Text File-------------------- 100
Opening a Saved File ----------------------- 102
Others
Troubleshooting ---------------------------- 105

v
ŔŢŧŦŵźġőųŦŤŢŶŵŪŰůŴġŢůťġŊůŴŵųŶŤŵŪŰůŴ
To ensure safety be sure to obey all of the following warnings.
The following items should be strictly obeyed for the safe usage of this unit,
and for protecting yourself and other people from bodily harm and/or damage
to property. To ensure the proper use of our product, please read the following
carefully and fully understand the contents.
Explanation of Symbols
Explanation of Warning Symbols
DANGER
These entries are actions that absolutely under no
circumstance should be taken. The taking of such
an action may cause serious personal physical
damage or death.
CAUTION These entries are actions that if taken may lead to
physical injury or damage to persons or things.
Explanation of Picture Symbols
Denotes an important warning or caution.
Denotes a forbidden action. Inside or near the symbol will
appear another symbol giving details.
(EX : stands for DO NOT TAKE APART)
Denotes an action that you must take.

vi
Introduction
DANGER
Be sure to follow the warnings and notices about use
from your PC maker when installing and using this unit.
Do not take apart, repair or modify the main unit.
Doing so may cause fire or electrocution.
If water or a foreign body enters in this unit, turn the
power off and remove the batteries. Continued use may
cause fire or electrocution.
Do not use this unit in wet or humid places, such as a
bathroom.
Store RTR-50 main units, batteries and communication
cables out of the reach of children.
It is dangerous to touch or swallow batteries.
Do not connect the communication cable to a telephone line.
It may cause a fire or other trouble including malfunction.
If any smoke or strage smells are emitted from the unit,
immediately remove the batteries and stop using.
Continued use may cause fire or electrocution.
Do not drop the unit, or expose the unit to a strong
impact. If that happens to the unit, immediately turn the
power OFF and remove the batteries.
Continued use may cause fire or electrocution.

vii
CAUTION
This unit is not water-resistant.
If the unit gets dirty, wipe it with a clean cloth and a mild
detergent.
Please do not insert your fingers or any foreign objects into any
of the devices' jacks.
Battery terminals may provide insufficient contact due to age or
vibration.
This may lead to data loss.
Do not use any other batteries than those that are specified in
this User's Manual.
It may cause a fire or other trouble including malfunction.
Battery terminals may provide insufficient contact due to
age or vibration. This may lead to data loss.
Condensation may occur if the unit is moved from one
environment to another where the difference in
temperature is great. Use the unit in an environment
where the ambient temperature is from -10 to 60Ɏand the
humidity is 90ɓRH (no condensation) or less.

viii
Introduction
Do not use or store the Thermo Recorder in any of the following
places. Doing so may cause electrocution, fire and/or other
adverse effects to the device and/or your computer.
- Areas exposed to direct sunlight
This will cause the inside of the device to become overheated
and may cause fire, deformation, and/or other damage
including malfunction.
- Areas prone to strong magnetic fields
This may cause damage including malfunction.
- Areas exposed to water leakage
This may cause electrocution or other damage incluing
malfunction.
- Areas exposed to excessive vibration
This may cause injury, malfunction, damage or loss of proper
electrical contact.
- Areas near fire or exposed to excessive heat
This may cause damage including malfunction and
deformation.
- Areas prone to smoke, duct and dirt
This may cause damage including malfunction.

1
Wireless Regulations
- RTR-50 complies with technical specifications required under
EN 301 489-3 (with battery and AC Adapter), EN 300-220-3
and EN 60950-1:2001/IEC 60950-1:2001
- Allowed to use in : A. B. D. DK. F. I. P. S. SW. UK. N. NL. CH.
FIN. PL. CZ. SK. IR. LT. LV. ML. EE. TUR
Other manuals for RTR-50
1
Table of contents
Other T&D Network Hardware manuals
Popular Network Hardware manuals by other brands

Matrix Switch Corporation
Matrix Switch Corporation MSC-HD161DEL product manual

B&B Electronics
B&B Electronics ZXT9-IO-222R2 product manual

Yudor
Yudor YDS-16 user manual

D-Link
D-Link ShareCenter DNS-320L datasheet

Samsung
Samsung ES1642dc Hardware user manual

Honeywell Home