Sturdy SA-300MA User manual

“
“S
St
tu
ur
rd
dy
y”
”
A
Au
ut
to
oc
cl
la
av
ve
e
S
St
te
er
ri
il
li
iz
ze
er
r
SA-300MA / SA-300MA-R
Instruction Manual
Please read manual carefully before using and keep it well.


Contents
1. Important Safety Instructions ................................................................................................1
2. Explanation of Safety Symbols and Notes ..........................................................................10
3. Unpacking........................................................................................................................... 11
4. Installation........................................................................................................................... 12
4.1 Environment.................................................................................................................. 12
4.2 Install the sterilizer ........................................................................................................ 12
5. Introduction ......................................................................................................................... 17
5.1 Intended Use................................................................................................................. 17
5.2 Description of the Sterilizer ........................................................................................... 17
5.2.1 External View......................................................................................................17
5.2.2 Internal Configuration .........................................................................................18
5.2.3 Control Panel (Re-Dry Program).........................................................................19
5.2.4 Control Panel ( Liquid Program ) / ( Optional by order request ).........................20
6. Operation ............................................................................................................................ 21
6.1 Operation Overview ......................................................................................................21
6.1.1 Re-Dry Program..................................................................................................21
6.1.2 Liquid Program ...................................................................................................22
6.1.3 PUMP test / BD test / PRION..............................................................................23
6.2 Prepare Sterilization......................................................................................................24
6.3 Standard Sterilization Program ..................................................................................... 25
6.4 Re-Dry Program (exclusive either to liquid or flash functions) ......................................26
6.5 Liquid Program (optional, exclusive either to Re-Dry or Flash function) .......................27
6.7 PRION Program............................................................................................................29
6.8 B.D. TEST Program ...................................................................................................... 30
6.9 PUMP TEST Program...................................................................................................32
6.10 Vacuum Release.........................................................................................................33
6.11 Reset / Stop................................................................................................................. 33
6.12 Emergency Stop.......................................................................................................... 33
6.13 Placement for items to be sterilized ............................................................................33
6.13.1 Sterilization for Implements...............................................................................34
6.13.2 Sterilization for Wrap......................................................................................... 36
6.13.3 Placement for sterilization box .......................................................................... 36
6.13.4 Glassware......................................................................................................... 37
7. Recorder (SA-300MA-R)........................................................................................................38
7.1 Intended use .................................................................................................................38
7.2 Recording contents .......................................................................................................38
7.2.1 Description of Detail Content ..............................................................................39

7.2.2 Description of Summary Contents ......................................................................40
7.3 Storage medium............................................................................................................42
7.4 Recorder panel ............................................................................................................. 43
7.5 Function description of the recorder.............................................................................. 43
7.5.1 General ............................................................................................................... 44
7.5.1.1 Stand-by mode.................................................................................................44
7.5.1.2 Recording mode ..............................................................................................44
7.5.1.3 Adjusting mode ................................................................................................ 45
7.5.2 Set up .................................................................................................................46
7.5.2.1 Set up date and time........................................................................................ 46
7.5.2.2 Set up unit (temperature and pressure) ...........................................................46
7.5.2.3 Remove USB ................................................................................................... 47
7.5.2.4 Download.........................................................................................................48
7.5.2.5 Printer ..............................................................................................................48
7.5.2.6 SN:...................................................................................................................49
7.5.2.7 Cycle:...............................................................................................................49
7.5.2.8 Exit...................................................................................................................49
7.6 Message and troubleshooting (for recorder) .................................................................50
8. Test Instructions .....................................................................................................................51
8.1 Biological performance of sterilizers .............................................................................51
8.2 Air removal (Bowie-Dick type test pack)........................................................................ 52
8.3 Helix test .......................................................................................................................54
9. Maintenance Instructions ....................................................................................................56
9.1 Daily..............................................................................................................................56
9.2 Weekly .......................................................................................................................... 56
9.3 Monthly .........................................................................................................................58
9.4 Annually ........................................................................................................................ 59
9.4.1 Silicone door gasket ...........................................................................................59
10. Troubleshooting ...................................................................................................................60
10.1 Symptoms...................................................................................................................60
10.2 List of Error Codes (for autoclave) ..............................................................................61
11. Specifications...............................................................................................................62
12. Warranty ......................................................................................................................63

1
1. Important Safety Instructions
In order to clearly indicate the extent of the harm, loss or damage which may result from falling
to heed these precautions and the degree of their urgency, the precaution have been classified
into the three categories of Danger, Warning and Caution.
Danger:This indicates an imminently hazardous situation arising from the mishandling
or mis-operation of the unit which, if not avoided, might cause the death or
serious injury of the operator or other persons.
Warning:This indicates a potentially hazardous situation arising form the mishandling
or mis-operation of the unit which, if not avoided, might cause the death or
serious injury of the operator or other persons.
Caution:This indicates a potentially hazardous situation arising form the mishandling
or mis-operation of the unit which, if not avoided, may cause the minor injury
of the operator or other persons and property damage.
Warning: Please install, operate and maintain the sterilizer in accordance with this
Instruction Manual. Failure to do so could result in serious injury or damage to the
unit.
Figure 1
Please read
manual.

2
Warning: DO NOT place alcohol or other flammable items in the sterilizer. An explosion could
occur, causing personal injury.
Figure 2
Warning: A separate (dedicated) circuit is recommended for the sterilizer. The sterilizer
should not be connected to an electrical circuit with other appliances or
equipment.
Figure 3
Warning: Always check the status of the electric wire; unplug the power cord if breakage
comes up. Contact your supplier for service support.
Figure 4
Gasoline
Alcohol
Gas
Chemical……

3
Warning: Children are not allowed to use or play with the unit.
Figure 5
Warning: Do not put your fingers into the gap on the hinged side of the door.
Figure 6
Warning: Always check the pressure gauge before opening the door. DO NOT attempt to
open the door if the pressure is not at zero (0).
Figure 7
Check Pressure
at “ZERO”

4
Warning: In an emergency, or before carrying out any maintenance, always disconnect the
power cord from the outlet.
Figure 8
Warning: Use sterilization indicator test strips to check that sterilization has been
successful.
Figure 9
Warning: If the ALARM indicator light illuminates, the machine is over-pressure or
overheated. The sterilizer will shut down automatically. Contact your supplier for
service support.
Figure 10
Please!!! Call
Service supplier

5
Warning: Use only distilled water. Normal tap water contains minerals, especially chlorides,
which have corrosive effects on stainless steel. Failure to use distilled water will
invalidate the warranty.
Figure 11
Caution: Do not put objects on the power plug or power cord.
Figure 12
Caution: The outer casing and metal surfaces of the sterilizer will be hot during operation,
please do not touch it.
Figure 13
Pure Water
City Water
Groundwater
……

6
Caution: Do not place objects on top of the water intake cap.
Figure 14
Caution: Always check the water level in the reservoir before running a sterilization cycle. If
the LOW WATER indicator light illuminates, add distilled water. If the water is
sufficient, but the LOW WATER indicator light is still illuminating, refer to
Troubleshooting.
Figure 15
Caution: Do not overfill the water reservoir. The water level must be maintained between
the green Full and Minimum labels on the right hand side of the sterilizer.
Figure 16
This manual suits for next models
1
Table of contents
Popular Laboratory Equipment manuals by other brands

Agilent Technologies
Agilent Technologies 5800 ICP-OES user guide

Endress+Hauser
Endress+Hauser Cleanfit CPA875 operating instructions

NI
NI PXI-5422 CALIBRATION PROCEDURE

Collomix
Collomix Aqix operating instructions

SPEX SamplePrep
SPEX SamplePrep 6875 Freezer/Mill Series operating manual

Ocean Insight
Ocean Insight FLAME-NIR+ Installation and operation manual

Parker
Parker ALIGN-MG-NA Installation, operation and maintenance manual

BD
BD 644787 user guide

DENTAURUM
DENTAURUM Compact Megaplus Instructions for use

Biuged Laboratory Instruments
Biuged Laboratory Instruments BGD 626 instruction manual

VWR
VWR SAS Super IAQ instruction manual

illumina
illumina MiSeqDx reference guide