First Steps
SSV SOFTWARE SYSTEMS Document Revision 1.4 // 2023-07-11

Introduction
2
IGW/935 //
First Steps
CONTENT
1
INTRODUCTION .................................................................................................... 3
1.1
Checklist .................................................................................................................... 3
1.2
Required Equipment ................................................................................................. 3
1.3
Document Conventions ............................................................................................. 3
2
SAFETY GUIDELINES .......................................................................................... 4
3
CONNECTIONS ..................................................................................................... 5
3.1
Ethernet Link ............................................................................................................. 5
3.2
RS485 Seri l Link ....................................................................................................... 6
3.3
Power Supply ............................................................................................................. 7
4
OPERATION .......................................................................................................... 8
4.1
Accessing the SSV/WebUI ......................................................................................... 8
4.2
Accessing the SSV/WebUI with DHCP en bled ......................................................... 9
4.3
Firew ll Configur tion ............................................................................................. 11
4.4
LAN Configur tion ................................................................................................... 12
4.5
Accessing the SSV/WebUI Demo P ge .................................................................... 13
4.6
Access vi Telnet ..................................................................................................... 14
4.7
Access vi FTP .......................................................................................................... 15
5
SOFTWARE EXPANSIONS & APPS .................................................................. 17
6
TROUBLE SHOOTING IP ADDRESS PROBLE S ............................................ 17
7
TECHNICAL INFOR ATION .............................................................................. 18
7.1
Technic l D t ......................................................................................................... 18
7.2
Pinout Screw Termin ls ........................................................................................... 18
8
HELPFUL LITERATURE ..................................................................................... 19
CONTACT ................................................................................................................. 19
DOCU ENT HISTORY ............................................................................................. 19

Introduction
IGW/935 // First Steps
3
1 INTRODUCTION
This documentation gives you an overview about the initial operation and the first steps of use with
the Web Application Gateway IGW/935
1.1 Checklist
Compare the content of your IGW/935 package with the checklist below If any item is missing or ap-
pears to be damaged, please contact SSV
Web Application Gateway IGW/935 with eSOM/3517
Documentation
Plu -in power supply
CD-ROM for eSOM/3517
Screwdriver
1.2 Required Equipment
To operate the IGW/935 the following hardware is required:
One Ethernet cross-over cable or two Ethernet patch cables and a switch.
To configure the IGW/935 a PC with the following features is required:
Windows 7 or hi her
Web browser (e. . Firefox, Chrome)
Telnet/SSH client (e. . TeraTerm)
FTP client (e. . FileZilla)
10/100 Mbps Ethernet network controller and TCP/IP confi uration
CD-ROM drive
1.3 Document Conventions
Convention
Usage
bold
Important terms
monospace
Filenames, Pathnames, program code, command lines
Table 1: Conventions used in this document

Safety Guidelines
4
IGW/935 //
First Steps
2 SAFETY GUIDELINES
Please read the followin safety uidelines carefully! In case of property or personal dama e by
not payin attention to this document and/or by incorrect handlin , we do not assume liability. In
such cases any warranty claim expires.
ATTENTION!
OBSERVE PRECAUTIONS FOR HANDLING – ELECTROSTATIC SENSITIVE DEVICE!
The power supply should be in immediate proximity to the device.
The power supply must provide a stable output volta e at 12 .. 24 VDC ±10%. The output
power should be at least 10 W.
Please pay attention that the power cord or other cables are not squeezed or dama ed in
any way when you set up the device.
Do NOT turn on the power supply while connectin any cables, especially the power cables.
This could cause dama ed device components! First connect the cables and THEN turn the
power supply on.
The installation of the device should be done only by qualified personnel.
Dischar e yourself electrostatic before you work with the device, e. . by touchin a heater
of metal, to avoid dama es.
Stay rounded while workin with the device to avoid dama e throu h electrostatic dis-
char e.
The case of the device should be opened only by qualified personnel.

Connections
IGW/935 // First Steps
5
3 CONNECTIONS
For a quick and easy start with the IGW/935 there are a few cable connections necessary The follow-
ing chapters describe how these connections have to be made
3.1 Ethernet Link
The Ethernet link between the PC and LAN1 of the IGW/935 can be made on two ways:
Direct with an Ethernet cross-over cable like shown in fi ure 1
With two standard Ethernet patch cables over a hub or switch like shown in fi ure 2
Fi ure 1: Ethernet link with cross-over cable
Please note:
For the Ethernet connection in fi ure 1 it is required to use a cross-over cable
Do not use an ordinary patch cable Both types of cables are in most cases visu-
al indistinguishable But the internal wiring is fully different Mixing up these
types of cables leads to LAN errors Hence pay attention to the label of the ca-
ble or packing
Fi ure 2: Ethernet link with hub or switch
The IP address of the LAN1 interface is ex-factory set to 192.168.0.126

Connections
6
IGW/935 //
First Steps
3.2 RS485 Seri l Link
To create an RS485 serial link on port COM1 of the Fehler! Verwenden Sie die Re isterkarte 'Start',
um Produktname dem Text zuzuweisen, der hier an ezei t werden soll. connect an RS485 device
like shown in fi ure 3
Fi ure 3: Layout of IGW/935
Terminal
Signal
A1
COM2 Serial Port: RS485 RX/TX+
A2
COM2 Serial Port: RS485 RX/TX
-
A4
Vin
-
Table 2: Pinout screw terminals COM1
Please note:
The RS485 (officially called TIA/EIA-485-A) connection between your IGW/935
and the field devices needs termination resistors on both ends for proper oper-
ation The IGW/935 does not offer internal termination resistors Please make
sure, that the RS485 cable connection is equipped with external termination re-
sistors.

Connections
IGW/935 // First Steps
7
3.3 Power Supply
The IGW/935 needs a supply voltage of 12 24 VDC ±10% to work
Connect the cables of an appropriate power supply to provide the system with the necessary power
like shown in fi ure 5
Fi ure 4: Power supply for the IGW/935
Terminal
Signal
A
3
Vin
+
(1
2
2
4
VDC
±10%
)
A
4
V
in
-
Table 3: Pinout screw terminals power
CAUTION!
Providing the IGW/935 with a higher voltage than the regular 12 24 VDC ±10%
could cause damaged device components!
Do NOT turn on the power supply while connecting it with the IGW/935 This
could cause damaged device components! First connect the power supply and
THEN turn it on.

Operation
8
IGW/935 //
First Steps
4 OPERATION
Just power up the IGW/935 and the boot process starts immediately The IGW/935 boots thereby an
embedded Linux out of its Flash memory This may take up to one minute
4.1 Accessing the SSV/WebUI
To open the login page of the SSV/WebUI enter the ex-factory IP address and port number of LAN1
of the IGW/936 manually in a web browser:
http://192.168.0.126:7777*
The username is admin, the password is ssvadmin
Fi ure 5: Lo in pa e of the SSV/WebUI
Please note:
To access the SSV/WebUI, it is important to add the port number 7777 to the
current IP address of the IGW/935.

Operation
IGW/935 // First Steps
9
4.2 Accessing the SSV/WebUI with DHCP en bled
If the automatic IP address configuration of LAN1 via DHCP is enabled, you have to check the as-
signed IP address, which is necessary to access the IGW/935 via a Telnet client or a web browser
Therefore open in Windows Control Panel > Network and Internet > View network computers and
devices The IGW/935 should show up in this list
Fi ure 6: Selectin the IGW/935
Just ri ht-click on the IGW/935 to open the properties dialog, where you can see the current IP ad-
dress of the IGW/935 like shown in fi ure 7
A double-click on the IGW/935 opens the SSV/WebUI in a web browser
Please note:
To access the SSV/WebUI, it is important to add the port number 7777 to the
current IP address of the IGW/935, e g : http://192.168.0.126:7777!

Operation
10
IGW/935 //
First Steps
Fi ure 7: The properties dialo shows the current IP address
Now you are able to access the IGW/935 via a Telnet client or a web browser
Other manuals for IGW/935
2
Table of contents
Other SSV Gateway manuals
Popular Gateway manuals by other brands

LST
LST M500RFE-AS Specification sheet

Kinnex
Kinnex Media Gateway quick start guide

2N Telekomunikace
2N Telekomunikace 2N StarGate user manual

Mitsubishi Heavy Industries
Mitsubishi Heavy Industries Superlink SC-WBGW256 Original instructions

ZyXEL Communications
ZyXEL Communications ZYWALL2 ET 2WE user guide

Telsey
Telsey CPVA 500 - SIP Technical manual