Snom M700 User manual

snom M700, snom M300
Base stations
Admin and Installation Guide
v1.1

Version1.1 Page|2
snom M300 and M700 administration and installation
guide
Contents
Contents.............................................................................................................................................................2
DocumentHistory..............................................................................................................................................3
Introduction.......................................................................................................................................................4
IntendedAudience.............................................................................................................................................4
Abbreviations.....................................................................................................................................................4
Preinstallationinformation................................................................................................................................5
Environmentalconsiderations...............................................................................................................5
Wall/ceilingmounting...........................................................................................................................5
OperatingcontrolsandLED’s................................................................................................................5
Resetswitch.......................................................................................................................................5
Networkandpowerconnection............................................................................................................5
Generalsoftwareconsiderationsandrequirements.............................................................................6
Firstsetup..........................................................................................................................................................6
IdentifyingbaseIP‐addressandfirstlogin.............................................................................................6
Settingupaccountsandhandsets.........................................................................................................7
1.SetupaSIP‐server..........................................................................................................................7
2.Createanuseraccount..................................................................................................................8
3.RegisterHandset..........................................................................................................................10
FirmwareUpdate.................................................................................................................................12
FirmwareFiles:.................................................................................................................................12
FolderStructure:..............................................................................................................................12
Wirelessdevicefirmwareupgrade:.................................................................................................13
Wording...........................................................................................................................................................17

Version1.1 Page|3
Document History
RevisionAuthorIssueDateComments
0.1TimKoehler05‐Sep‐2014InitialVersion
1.0BenajminZiebarh01‐Oct‐2014InitialRelease
1.1BenjaminZiebarth9Dec2014Added:Handsetupdateinfo

Version1.1 Page|4
Introduction
ThisdocumentshallhelptoinstallandadministratethesnomMobilebasestationsM300andM700.
ThisdocumentdoesNOTcovertheinstallationofamulticellDECTsystem,inthiscasepleasereferto
thesnommulticelldeploymentguideforfurtherguidance.
Intended Audience
Thetargetaudienceforthisdocumentincludesnetworkadministrators.
Abbreviations
Forthepurposeofthisdocument,thefollowingabbreviationshold:
DHCP:DynamicHostConfigurationProtocol
(T)FTP:(Trivial)FileTransferProtocol
IOS: InternetworkingOperatingSystem
NAT: NetworkAddressTranslator
PCMA:A‐lawPulseCodeModulation
PCMU:mu‐lawPulseCodeModulation
RSSI:Receivedsignalstrengthindication
RTP:Real‐timeTransportProtocol
RPORT: ResponsePort(RefertoRFC3581fordetails)
SIP:SessionInitiationProtocol
SME: SmallandMediumscaleEnterprise
SRTP:SecureReal‐timetransportprotocol
STUN: SessionTraversalUtilitiesforNAT
TLS:TransportLayerSecurity(forSIPencryption)
VLAN:VirtualLocalAccessNetwork
TOS: TypeofService(policybasedrouting)
URL: UniformResourceLocator
UA: UserAgent
UTC:CoordinatedUniversalTime(similartoGMTformat)

Version1.1 Page|5
Pre-Installation information
Environmental considerations
PleaseinstalltheM300/M700basestationonlyindrylocationswhicharenotpotentiallyexplosive
atmosphere.
Don’tinstallthebasenearairconditions,radiators,indirectsunexposure,verydustyplacesorwhere
itcouldbeexposedtowaterand/orchemicalsplashes.
Thebasestationsareshallonlybeusedindoor.
Environmentaltemperature:‐10°Cto+50°C(14°Fto122°F)
Humidity:max70%(noncondensing)
Itisrecommendedtonotinstallthebasestationdirectlyonmetalsurfacesandtomaintaina
minimumdistanceof20cm(8inches)fromcurrentlinesorwaterpipes;otherwisethereceptionmight
bedegraded.
Wall/ceiling mounting
ThesnomM300/M700canbewallmounted.OntheM700pleaseremovethefootstandprior
mounting.
TheM700canalsobemountedontheceilingwiththeoptionallyavailable“snomA700ceilingmount”
withtheproductnumber00003933.Pleasedonottrytoinstallthebasestationsontheceiling
withoutthismount,asthebasestationmayfalldown.
Operating controls and LED’s
ThebasestationshaveamulticolourLEDforstatussignalling.
StatusLED Systemstate
Solidgreen baseisoperational
blinkingorangebaseisbooting
blinkingred networkorregistrationfailure
off baseisinactive
blinkingrapidlybaseisupdatingsoftware
Resetswitch
Thebasehasaresetswitchonthebacktoreverttofactorydefaultsettings.Toperformafactory
reset,pleasepresstheswitchforatleast10seconds.
Network and power connection
TheM700doesnothaveapowerconnectionandrequirestheusageofPoweroverEthernet(PoE)
Class2.IfyournetworkisnotequippedwithaPoEinfrastructure,youcanusethe“snomA5PoE
injector”withtheproductnumber00004065.
TheM300basestationcomeswithapowersupply,pleaseonlyusethesuppliedpowersupplywith
theM300.TheM300doesnotsupportPoE.

Version1.1 Page|6
Bothbasestationshavea10/100Mbitautosensingnetworkport.
General software considerations and requirements
ThesnomM‐Seriesbasestationsfollowmostsnomspecificsnomconfigurationandmanagement
schemes.ItisrecommendedtohavealocalHTTP/HTTPSserverforfirmwareupdatesandcentral
configurationmanagement.
TheHTTP‐Serverwillhostfirmwarefilesforbasestations,handsetsandrepeaters.Thehandsetsand
repeaterscanbeupdatedovertheairbythebasestation.
First setup
ThefirstsetupwillguidethroughtheprocessofidentifyingthebasestationsIP‐address,tologinand
tosetupthefirsthandsetandSIP‐registration.
ThisguidewillNOTdescribehowtosetupM700inamulticellconfiguration.
Note:ThescreenshotsaretakenfromanM700basestationandanM65handset.Where
applicableindividualscreenshotsaretaken.
Identifying base IP-address and first login
Onceyouconnectedthebasestationtopowerandnetworkasdescribedbefore,takeasnom
M65/M25handsetandpressthe“Menu”keyandenter“*47*”.ThiswillshowthebasestationsIP‐
addressesinrange:
PleaseentertheIP‐addressofthebasetoconfigureintoyourwebbrowser.
ThestandardAdministrationcredentialsare:
Username: admin
Password:admin
Youwillbepresentedwiththefollowingscreen:

Version1.1 Page|7
Note:Afterthefirstlogin,pleasegotothesecuritytabandchangetheadminloginpassword
immediatelytopreventthatthirdpartieshaveaccesstotheinstallation.
Setting up accounts and handsets
Threestepsarerequiredtomakethefirstphonecall:
1.SetupaSIP‐server
PleasestarttosetupaSIP‐server,byclickingonServers.

Version1.1 Page|8
Theserverpageletsyouconfigureserverspecificsettings,suchasCodecpriorities,RTPsettings,
encryption,etc.
2.Createanuseraccount
NowclickonExtensionstocreateuseraccounts(considercreatingallrequireduseraccountsatthis
stage,theywillbeassociatedwiththehandsetsinthenextstep):

Version1.1 Page|9
Thenclickon“Addextension”:

Version1.1 Page|10
3.RegisterHandset
Backattheextensionpage,youwillnotice,thatthenewlycreatedaccountisassociatedwitha
handsetwhichhastheIPEIFFFFFFFFFF,thismeansthatnohandsethasbeenassociatedwiththisSIP
extension.
Selectthe“unregistered”extensionbysettingthecheck‐markandclickon“RegisterHandset(s)”.Now
takeyourhandset,pressMenuandselect“Connectivity”:
Other manuals for M700
5
This manual suits for next models
1
Table of contents
Other Snom Accessories manuals