COMPONENTS THAT MAKE IT WORK
PREFILTER traps the larger particles and evenly distributes
the air across the ionizing section to maximize efficiency.
IONIZER is made up of fine tungsten wires supported
between metal plates. When high voltage is applied to
these parts, a “corona” field is generated which imparts
a high-voltage charge on particles that pass through it.
COLLECTION CELL is made up of a series of convoluted
metal plates. These plates act like a magnet and attract
the charged particles removing them from the air. The
plates are alternately charged positive and ground. The
positive plates repel the particles while the ground plates
attract them, yielding a very high efficiency.
NOTE: The SE 40 contains an ionizer and collection cell as
a one piece assembly known as a unicell.
SPEED CONTROL SWITCH allows you to adjust the airflow
between 150 and 420 cubic feet of air per minute (CFM)
on the SE 30 and 450 and 950 CFM on the SE 40. The
switch on the SE 50 allows you to adjust the airflow
between 1,060 and 1,500 CFM on the high speed tap
and between 590 and 1,300 CFM on the low speed tap.
The SE 50 is shipped on high tap.
MOTOR/BLOWER produces air movement by a low
speed, dynamically-balanced, forward-curved blower.
The direct drive motor is thermally protected.
IV. INSTALLATION
NOTE: This product has been designed specifically for
commercial applications, such as offices, night
clubs, bowling centers and bingo halls. United Air
Specialists assumes no responsibility for those
applications unlike the aforementioned.
CAUTION: To reduce the risk of electric shock, this
equipment has a grounding-type plug that has
a third (grounding) pin. This plug will only fit
into a grounding-type power outlet. If the plug
does not fit into the outlet, contact qualified
personnel to install the proper outlet. Do not
alter the plug in any way.
SMOKEETER is designed to draw the contaminated air
through the unit and exhaust clean air back into the
room. The clean air is used to push contaminated air
around the room to the inlet of the unit. Directions of air
patterns and proper placement of the unit should be
established by your local SMOKEETER distributor or by
United Air Specialists, Inc.
The unit can be installed by mounting on a wall or
suspending from the ceiling joists/structure.
I. INTRODUCTION
NOW YOU CAN BREATHE A LOT EASIER...
... you and everyone else who breathe the air cleaned
electronically by SMOKEETER®
. Your new electronic air
cleaner is the most advanced product of its type on the
market today. As you begin its operation, we would like
to remind you of a few important facts.
First, we appreciate your business and because we
appreciate your business, we have manufactured an
electronic air cleaner worthy of your consideration.
SMOKEETER is designed and engineered to rigid
specifications incorporating the latest technological
advances. It is built using the highest grade materials
available. It is subjected to rigorous quality control
checks before it leaves our factory. And, the unit is
backed by a factory warranty as described on the back
cover.
Second, like any piece of precision equipment, your
SMOKEETER unit needs periodic maintenance. Properly
cared for, it will operate at peak efficiency for many
years to come.
Finally, while we hope you never have any problems,
United Air Specialists, Inc. (UAS) is always ready to lend
assistance. We have factory-trained distributors
worldwide. Should you need information or service,
contact your local distributor or Customer Service at
United Air Specialists, Inc., 4440 Creek Road, Cincinnati,
Ohio 45242, 1-800-252-4647, www.uasinc.com.
II. INSPECTION OF EQUIPMENT
Upon receipt of your unit, check for any shipping
damage. A damaged carton indicates that the
equipment may have received rough handling during
shipping that may have caused internal damage.
Notify your delivery carrier and enter a claim
if any damage is found.
Ill. HOW YOUR AIR CLEANER
OPERATES
The motor/blower assembly draws air through an
aluminum mesh filter which removes the larger particles in
the contaminated air. As the particles pass through the
ionizer section, they are given an intense positive charge.
These charged particles are then collected on cell plates.
The clean air is redistributed into the room by adjustable
outlet diffusers.
4