SKC QuickTake 30 User manual

Operating Instructions
Cat. No. 228-9530
SKC Inc.
863 Valley View Road
Eighty Four, PA 15330 USA
Form 40079 Rev 1504

Table of Contents
Quick Guide .........................................................................................1
Description...........................................................................................3
Performance Profile ............................................................................4
Battery Operation ................................................................................6
Operation............................................................................................10
Mounting Sampling Media................................................................12
Calibration and Setting Flow............................................................14
Setup...................................................................................................15
Sampling ............................................................................................17
Advanced Setup ................................................................................19
Maintenance.......................................................................................23
Warranty.............................................................................................23
Ordering Information.........................................................................24

1
QuickTake 30 Quick Guide
Terms »
Star Button
Turns on LED, toggles between displays, and exits without saving
Up and Down Arrow Buttons
Scroll through presets, increase or decrease sampling parameters, and toggle
between setup options
Button Sequence
or = Press individually
[] = Press both simultaneously
= Security code, press in sequence
Programming Sequences »
• To activate pump LED:
Press and hold for 2 seconds.
• To check battery status:
Press .
• To choose a run time preset:
Press or to scroll through presets. Once desired preset displays, press
[] to start sampling.
• To Run or Hold:
Press [].
• To repeat a sample run:
From Done, reset (rSEt), or sampling error (SErr), press [] to return to run
time preset. Press [] to sample.
• To change or calibrate flow:
Note: Flow rate does not appear on LED.
Press or and scroll to a run time preset. Press and hold CAL for 2 seconds.
(Does not require a security code.) Press or to change flow rate until desired
flow appears on calibrator. Press . When Stor displays, press [] to save
setting or to ignore changes to flow setting.
• To interrupt run, terminate a sample, or reset pump:
While in Hold, press . Sample reset (rSEt) will display. Press [] to reset
pump or to ignore reset and return to Hold.
www.skcinc.com
SKC Inc., 863 Valley View Road, Eighty Four, PA 15330

3
Description
The QuickTake®30 Sample Pump is a portable baery-powered air sampling
pump that maintains constant airflow from 10 to 30 L/min for use with impactors,
spore trap cassees such as VersaTrap®, asbestos cassees, microvacuum cassees,
or other samplers requiring flows up to 30 L/min. A diaphragm pump operating
with a closed loop flow control system, the QuickTake 30 maintains true constant
flow. The QuickTake 30 features a programmable timer that provides up to eight
programmable run time presets of 1 to 999 minutes, continuous run with manual
shut-off, or intermient sampling. A rechargeable lithium-ion baery pack provides
effective run times (see Performance Profile - Typical Cumulative Run Time on page 4).
Handle
for easy
portability
Charging jack
(on side of case,
not shown)
High-contrast
LED display
for readout of
presets, run
time, and
battery status
Calibration
mode button
Up arrow
increases flow
and time and
scrolls through
presets
Inlet
(shown without adapter)
LED
indicates active
battery charging
Down arrow
decreases flow and
time and scrolls
through presets
Star button
activates LED
and toggles
between displays
Speaker
for end of
timed run
alarm
Printed Quick Guide
Tubing AdapterCassette Adapter

4
Performance Profile
Flow Range: 10 to 30 L/min
Flow Compensation
Accuracy: ± 5% of set flow
Compensating Flow 10 L/min at 90 inches water back pressure
Back Pressure Range: 20 L/min at 50 inches water back pressure
30 L/min at 15 inches water back pressure
Power: • Rechargeable lithium-ion (Li-Ion) battery, 7.4 V, 9.6-Ah
capacity, 71.04 Wh
• Battery with AC charger/adapter, 100-240 V
Battery Recharge Time: Approximately 5 hrs
(varies with baery capacity
and level of discharge)
Typical Cumulative
Spore Trap* (e.g., VersaTrap):5 hrs at 15 L/min (battery only)
Run Time:†
BioStage viable cascade impactor: 4 hrs at 28.3 L/min (battery only)
25-mm, 1.2-μm MCE filter: 9+ hrs at 10 L/min
To achieve, use QuickTake 30 with a fully
charged battery and AC charger/adapter.
37-mm, 0.8-μm MCE filter: > 14 hrs at 10 L/min (battery only)
* Sampling times when using spore traps are usually ≤10 min. SKC
recommends reducing length of sample time when using a 30 L/min
flow rate to prevent overloading the media.
† Results obtained using a new pump and new fully charged baeries. Pump and
baery performance may vary.
The AC charger/adapter can be used to extend baery run
time, but it is not a baery eliminator. Therefore, it will
not provide indefinite run times.
Temperature: Operating: 32 to 113 F (0 to 45 C)
Storage: -4 to 95 F (-20 to 35 C)
Charging: 32 to 113 F (0 to 45 C)
Operating Humidity: 0 to 95% non-condensing
Protect sample pump from weather when in use outdoors.
Compare the information in this table to pump compensation range to determine appropriate applications.
Typical Back Pressure of Sampling Media (inches water)
Flow Rate (L/min) 10 12 15 20
Filter/Pore Size (μm)
25-mm MCE, 0.8 65 80 103 148
25-mm MCE, 0.45 138 172 > 200 —
37-mm MCE, 0.8 22 28 36 51
37-mm PVC, 5.0 9 11 15 21

5
Run Time Features: User-selectable features, user-adjustable presets (see
Advanced Setup)
Preset timed runs: 1, 2, 5, 10, or 15 min
Manually set continuous
run with manual shut-off: 1 to 999 min (repeats 1 to 999-min
runs indefinitely until user stops
pump or power supply is depleted)
Intermittent sampling: See Advanced Setup
Flow Fault Features: If the pump is unable to compensate due to excessive back
pressure, the pump will go into flow fault mode (see page 18 for
details). Flow fault features are enabled as the default setting.
Flow fault may be disabled at the user’s option.
See Advanced Setup.
Flow fault: Flow fault displays immediately
Pump shuts off after 5 seconds
Fault restart: Pump attempts restart every 10 seconds
up to five times
Media Compatibility: Viable cascade impactors, spore trap cassettes (e.g., VersaTrap),
asbestos cassettes, microvacuum cassettes, and other impaction
samplers that require flows from 10 to 30 L/min
Tubing: Requires 3/8-in ID tubing
Housing: ABS plastic
Dimensions: 9.3 x 8.4 x 3.5 in (23.6 x 21.3 x 8.9 cm)
Weight: 4.8 lbs (2.2 kg)
Indicates a warning, caution, or note
www.skcinc.com

6
Battery Operation
Battery Status Indicators
Full charge; approximately 75% to 100% baery capacity
remaining
Baery is charged enough to operate the pump;
approximately 25% to 75% baery capacity remaining.
Baery charge is low (charge baery); approximately
1% to 25% baery capacity remaining.
Low Baery Fault. Pump will stop running, beep, and
go to sleep in 10 seconds.
Charging the Battery
For a complete charge, ensure the
pump is not running during charging.
Insert the charger plug into the jack on
the pump and the charger into a wall
outlet. A red LED will flash on the
pump display to indicate the unit is
charging. When charging is complete,
the LED will stop flashing and the
pump will go to sleep. The baery charges completely in five hours. The QuickTake
30 can be operated using AC power. See Operating from AC Power on page 9.
After charging the baery pack, it is good practice to run the pump for
approximately 5 minutes before calibrating. This ensures the baery is in more
steady-state conditions and improves the agreement in pre and post-sampling
calibrations.
• The pump will not sleep during charging. Connecting a sleeping pump to the
charger will wake it up from sleep.
• The AC charger/adapter can be used to extend baery run time, but it is not
a baery eliminator. Therefore, it will not provide indefinite run times.
• Do not operate or charge the pump in hazardous locations.
• Use only the SKC-approved charger for this pump. Use of an unapproved
charger may damage the baery and the pump and voids any warranty.
• The baery pack may be kept on the SKC-approved charger for an indefinite
time.
• Ensure proper orientation of the charging cable before plugging it into the
charging jack. Improper orientation/contact will short circuit the baery and
voids any warranty.
• Short-circuiting the baery pack will render it immediately inoperative.
• Failure to follow warnings and cautions voids any warranty.
See www.skcinc.com/instructions/1756.pdf for more information on
SKC pump batteries.

7
Removing and Installing a Battery
1. With the back of the pump facing you (serial number
at boom left), use a small flat-head screwdriver
(tweaker) to pry up and remove two strip panels
from the left and right ends of the back of the case.
Removing the pressure-fit panels will reveal four
safety screws.
2. Use a Phillips head or flat-head screwdriver to
loosen the four safety screws.
3. Lift offthe back of the pump case.
4. Use a Phillips head screwdriver to loosen the
two screws (with washers) from the baery
bracket. Use forceps to remove screws and
washers from the case; set the screws aside.
Do not lose washers.
5. Lift the bracket slightly, slide it toward the
case handle, and lift it out of the case.
6. Detach the baery
from the baery
harness by pressing on
the connector tab (left
side of connector) and
pulling both sides of
the connector apart.
Battery harness
connector pulls apart.
Battery harness
connector
Battery
Battery
cavity
Bracket
screws
Battery Bracket
Slide bracket toward
case handle and lift out.
Battery harness wires
Case
handle

8
7. Using a full-size flat-head screwdriver, insert its tip underneath the baery
end nearest the case handle. Maneuver the screwdriver to apply an upward
force to the boom of the baery until the double-sided tape adhesive on its
boom releases its hold and the baery can be lifted from the case.
8. Aach the new baery to the baery harness connector by aligning the two
sides of the connector and pressing them together until they click.
9. Install the baery.
a. If installing a new baery (Cat. No. P75689), remove the protective strip
from double-sided mounting tape on the boom of the new baery to
expose adhesive.
b. If reinstalling the existing baery, remove as much of the previous
adhesive as possible from the boom of the baery. Remove the protective
strip from one side of a new two-inch piece of double-sided mounting
tape (available from SKC as Part No. 51872) and apply to the boom of
the baery. Remove the protective strip from the tape’s remaining side to
expose adhesive.
Ensure the battery harness wires on battery pack are facing away from the
case handle before inserting battery in case.
10. Align the baery in case (as shown above) before allowing the boom of the
baery to come into contact with and adhere to the pump base plate. Press
down gently to ensure the baery pack adheres to the base plate.
11. From the case handle side of the pump, slide the baery bracket into place
until two openings in the bracket are aligned with the two screw holes in the
pump base plate.
12. Use needlenose pliers to align the two screws with washers with the screw
holes. Tighten screws using a small flat-head screwdriver.
13. Replace the back of the pump case (serial number label should be in the lower
left corner) and tighten the four safety screws.
14. Replace the two strip panels and press them down until they are completely
installed.
STOP

9
Operating from AC Power
The QuickTake 30 may be run using AC power with the baery and AC
charger/adapter. Insert the charger plug into the jack on the pump and the
charger into a standard wall outlet. Operate the pump.
Cautions, Warnings, and Notes
• The charge light on the LED will flash if the baery is charging during AC
operation.
• The AC charger/adapter can be used to extend baery run time, but it
is not a baery eliminator. Therefore, it will not provide indefinite run
times.
• Do not operate or charge the pump in hazardous locations.
• Use only the SKC-approved baery and charger for this pump. Use of an
unapproved baery and/or charger may damage the baery and the pump
and voids any warranty.
• To reduce risk of injury, fire, or electric shock, always follow basic safety
precautions when using this product.
• Do not submerge the pump or subject it to any liquids.
• Protect the sample pump from weather when in use outdoors.
• Tampering with the baery pack or using a repaired or rebuilt baery
pack voids any warranty and UL Listing for intrinsic safety.
• Do not open, disassemble, short circuit, crush, incinerate, or expose the
baery to fire or high temperatures.
• Failure to follow warnings or cautions voids any warranty.
Other manuals for QuickTake 30
1
Table of contents
Other SKC Water Pump manuals

SKC
SKC 224-PCXR8M User manual

SKC
SKC AirChek 3000 User manual

SKC
SKC TOUCH Operating instructions

SKC
SKC AirChek XR5000 User manual

SKC
SKC 220 Series User manual

SKC
SKC 210-1002MTX User manual

SKC
SKC AirChek XR5000 User manual

SKC
SKC 224-PCMTX8 User manual

SKC
SKC 224-PCXR8 User manual

SKC
SKC AirChek TOUCH 220 Series User manual
Popular Water Pump manuals by other brands

Sykes AmeriPumps
Sykes AmeriPumps GP100M Operation and maintenance instructions

DUROMAX
DUROMAX XP WX Series user manual

BRINKMANN PUMPS
BRINKMANN PUMPS SBF550 operating instructions

Franklin Electric
Franklin Electric IPS Installation & operation manual

Xylem
Xylem e-1532 Series instruction manual

Milton Roy
Milton Roy PRIMEROYAL instruction manual