SICK WTB4S-3 User manual

OPERATING I N S T R U C T I O N
en / de / fr / it / pt / es / zh / ru
SICK AG, Erwin-Sick-Strasse 1, D-79183 Waldkirch
8012134.10DT
2006/42/EG
NO
SAFETY

Photoelectric proximity sensor
Operating instructions
1Safety notes
■Read the operating instructions before commissioning.
■Connection, mounting, and setting may only be performed by trained specialists.
■Not a safety component in accordance with the EU Machinery Directive.
■UL: Only for use in applications in accordance with NFPA 79. These devices shall
be protected by a 1 A fuse suitable for 30 V DC. Adapters listed by UL with connec‐
tion cables are available. Enclosure type 1.
■When commissioning, protect the device from moisture and contamination.
■These operating instructions contain information required during the life cycle of
the sensor.
2 Correct use
The WTB4S-3 is an opto-electronic photoelectric proximity sensor (referred to as "sen‐
sor" in the following) for the optical, non-contact detection of objects, animals, and per‐
sons. If the product is used for any other purpose or modified in any way, any warranty
claim against SICK AG shall become void.
Photoelectric proximity sensor with background suppression.
Image: A
3 Commissioning
1 Mount the sensor using a suitable mounting bracket (see the SICK range of acces‐
sories).
Note the sensor's maximum permissible tightening torque of 0.8 Nm.
Note the preferred direction of the object relative to the sensor [see A].
2 The sensors must be connected in a voltage-free state (VS = 0 V). The information
in the graphics [B] must be observed, depending on the type of connection:
8012134.10DT | SICK
Subject to change without notice 1
Specifications see page 50.

– Male connector connection: pin assignment
– Cable: core color
Image: B
Only apply voltage/switch on the power supply (VS > 0 V) once all electrical connec‐
tions have been completed. The green LED indicator lights up on the sensor.
Explanations of the connection diagram (Graphic B):
Switching outputs Q and /Q (according to Graphic B):
WTB4S-3Exxxx and WTB4S-3Fxxxx
D: dark-switching, output (Q) switches off when an object is present in the sensing
range.
WTB4S-3P1362 and WTB4S-3Px1xx
WTB4S-3N1362 and WTB4S-3Nx1xx
L: light switching, output (Q) switches when an object is present in the sensing ran‐
ge.
WTB4S-3P1161 and WTB4S-3N1161
WTB4S-3Px261 and WTB4S-3Nx261
ANT: complementary outputs Q and Q/
3 Align the sensor with the object. Select the position so that the red emitted light
beam hits the center of the object. You must ensure that the optical opening (front
screen) of the sensor is completely clear [E]. We recommend making the adjust‐
ments using an object with a low remission.
Image: E
4
3 COMMISSIONING
28012134.10DT | SICK
Subject to change without notice

Sensor with potentiometer:
The sensing range is adjusted with the potentiometer (type: with stop5-gear). Clock‐
wise rotation: sensing range increased; counterclockwise rotation: sensing range
reduced. Position the object and direct the light spot onto it. Red emitted light spot
can be detected on the object. Turn the adjustment to the minimum scanning ran‐
ge. Then increase the scanning range until the yellow LED indicator lights up. Re‐
commended: If high contrast or poorly remitting objects are detected, increase the
scanning range by adding a safety supplement of 15% of the scanning range (cf.
F). Once the sensing range has been adjusted, the object is removed from the path
of the beam, which causes the background to be suppressed and the switching
output to change (see Graphic C/D).
The sensor is adjusted and ready for operation. Refer to Graphics C/D and G to
check the function. If the switching output fails to behave in accordance with Gra‐
phic C/D, check application conditions. See section Fault diagnosis.
Image: C
Image: G
5 Fault diagnosis
Table indicates which measures are to be taken if the sensor stops working.
4
3
8012134.10DT | SICK
Subject to change without notice

6 Table Fault diagnosis
LED indicator/fault pattern /
LED indicator/fault pattern
Cause /
Cause
Measures /
Measures
Green LED does not light up /
Green LED does not light up
No voltage or voltage below
the limit values /
No voltage or voltage below
the limit values
Check the power supply,
check all electrical connecti‐
ons (cables and plug connecti‐
ons) /
Check the power supply,
check all electrical connecti‐
ons (cables and plug connecti‐
ons)
Green LED does not light up /
Green LED does not light up
Voltage interruptions /
Voltage interruptions
Ensure there is a stable power
supply without interruptions /
Ensure there is a stable power
supply without interruptions
Green LED does not light up /
Green LED does not light up
Sensor is faulty /
Sensor is faulty
If the power supply is OK, re‐
place the sensor /
If the power supply is OK, re‐
place the sensor
Yellow LED flashes /
Yellow LED flashes
Sensor is still ready for opera‐
tion, but the operating conditi‐
ons are not ideal /
Sensor is still ready for opera‐
tion, but the operating conditi‐
ons are not ideal
Check the operating conditi‐
ons: Fully align the beam of
light (light spot) with the ob‐
ject. / Clean the optical surfa‐
ces . / Readjust the sensitivity
(potentiometer) / Check sen‐
sing range and adjust if ne‐
cessary; see graphic F. /
Check the operating conditi‐
ons: Fully align the beam of
light (light spot) with the ob‐
ject. / Clean the optical surfa‐
ces . / Readjust the sensitivity
(potentiometer) / Check sen‐
sing range and adjust if ne‐
cessary; see graphic F.
Yellow LED lights up, no object
in the path of the beam /
Yellow LED lights up, no object
in the path of the beam
/ Distance between the sen‐
sor and the background is too
short /
/ Distance between the sen‐
sor and the background is too
short
Reduce the sensing range,
see graphic F /
Reduce the sensing range,
see graphic F
Object is in the path of the be‐
am, yellow LED does not light
up /
Object is in the path of the be‐
am, yellow LED does not light
up
Distance between the sensor
and the object is too long or
sensing range is set too
short /
Distance between the sensor
and the object is too long or
sensing range is set too short
Increase the sensing range,
see graphic F /
Increase the sensing range,
see graphic F
7 Disassembly and disposal
The sensor must be disposed of according to the applicable country-specific regulati‐
ons. Efforts should be made during the disposal process to recycle the constituent ma‐
terials (particularly precious metals).
6 TABLE FAULT DIAGNOSIS
48012134.10DT | SICK
Subject to change without notice

8 Maintenance
SICK sensors are maintenance-free.
We recommend doing the following regularly:
•Clean the external lens surfaces
•Check the screw connections and plug-in connections
No modifications may be made to devices.
Subject to change without notice. Specified product properties and technical data are
not written guarantees.
MAINTENANCE 8
5
8012134.10DT | SICK
Subject to change without notice

Reflexions-Lichttaster
Betriebsanleitung
9 Sicherheitshinweise
■Vor der Inbetriebnahme die Betriebsanleitung lesen.
■Anschluss, Montage und Einstellung nur durch Fachpersonal.
■Kein Sicherheitsbauteil gemäß EU-Maschinenrichtlinie.
■UL: Nur zur Verwendung in Anwendungen gemäß NFPA 79. Diese Geräte müssen
mit einer für 30V DC geeigneten 1A-Sicherung abgesichert werden. Von UL geliste‐
te Adapter mit Anschlusskabeln sind verfügbar. Enclosure type 1.
■Gerät bei Inbetriebnahme vor Feuchte und Verunreinigung schützen.
■Diese Betriebsanleitung enthält Informationen, die während des Lebenszyklus des
Sensors notwendig sind.
10 Bestimmungsgemäße Verwendung
Die WTB4S-3 ist ein optoelektronischer Reflexions-Lichttaster (im Folgenden Sensor ge‐
nannt) und wird zum optischen, berührungslosen Erfassen von Sachen, Tieren und Per‐
sonen eingesetzt. Bei jeder anderen Verwendung und bei Veränderungen am Produkt
verfällt jeglicher Gewährleistungsanspruch gegenüber der SICK AG.
Reflexionslichttaster mit Hintergrundausblendung.
Abb.: A
6
Technische Daten siehe Seite 50.
8012134.10DT | SICK
Subject to change without notice

11 Inbetriebnahme
1 Den Sensor an einen geeigneten Befestigungswinkel montieren (siehe SICK-Zube‐
hör-Programm).
Maximal zulässiges Anzugsdrehmoment des Sensors von 0.8 Nm beachten.
Vorzugsrichtung des Objektes zum Sensor beachten [vgl. A].
2 Anschluss der Sensoren muss spannungsfrei (VS = 0 V) erfolgen. Je nach An‐
schlussart sind die Informationen in den Grafiken [vgl. B] zu beachten:
– Steckeranschluss: Pinbelegung
– Leitung: Adernfarbe
Abb.: B
Erst nach Anschluss aller elektrischen Verbindungen die Spannungsversorgung (VS
> 0 V) anlegen bzw. einschalten. Am Sensor leuchtet die grüne Anzeige-LED.
Erläuterungen zum Anschlussschema (Grafik B):
Schaltausgänge Q bzw. /Q (gemäß Grafik B):
WTB4S-3Exxxx und WTB4S-3Fxxxx
D: dunkelschaltend, Ausgang (Q) schaltet aus, wenn sich ein Objekt im Tastbereich
befindet.
WTB4S-3P1362 und WTB4S-3Px1xx
WTB4S-3N1362 und WTB4S-3Nx1xx
L: hellschaltend, Ausgang (Q) schaltet, wenn sich ein Objekt im Tastbereich befin‐
det.
WTB4S-3P1161 und WTB4S-3N1161
WTB4S-3Px261 und WTB4S-3Nx261
ANT: Antivalente Ausgänge Q und Q/
3 Sensor auf Objekt ausrichten. Positionierung so wählen, dass der rote Sendelicht‐
strahl in der Mitte des Objekts auftrifft. Es ist darauf zu achten, dass die optische
Öffnung (Frontscheibe) des Sensors vollständig frei ist [vgl. E]. Wir empfehlen, die
Einstellung mit einem Objekt von niedriger Remission vorzunehmen.
BESTIMMUNGSGEMÄSSE VERWENDUNG 10
7
8012134.10DT | SICK
Subject to change without notice

Abb.: E
4
Sensor mit Potentiometer:
Mit dem Potentiometer (Art: Anschlag Anschlag5-Gang) wird der Schaltabstand ein‐
gestellt. Drehung nach rechts: Erhöhung des Schaltabstandes, Drehung nach links:
Verringerung des Schaltabstandes. Objekt positionieren und Lichtfleck auf Objekt
ausrichten. Roter Sendelichtfleck auf dem Objekt erkennbar. Einstellung auf mini‐
malen Schaltabstand drehen. Dann Schaltabstand so lange erhöhen, bis gelbe An‐
zeige-LED aufleuchtet. Empfehlung: Sollen kontrastreiche oder schlecht remittie‐
rende Objekte erkannt werden, den Schaltabstand mit einem Sicherheitsaufschlag
von 15% des Objektabstandes versehen (vgl. F). Nachdem der Schaltabstand ein‐
gestellt worden ist, das Objekt aus dem Strahlengang entfernen, der Hintergrund
wird dabei ausgeblendet und der Schaltausgang ändert sich (siehe Grafik C/D).
Sensor ist eingestellt und betriebsbereit. Zur Überprüfung der Funktion Grafik C/D
und G heranziehen. Verhält sich der Schaltausgang nicht gemäß Grafik C/D, Ein‐
satzbedingungen prüfen. Siehe Abschnitt Fehlerdiagnose.
11 INBETRIEBNAHME
88012134.10DT | SICK
Subject to change without notice

Abb.: C
Abb.: G
13 Fehlerdiagnose
Tabelle I zeigt, welche Maßnahmen durchzuführen sind, wenn die Funktion des Sensors
nicht mehr gegeben ist.
14 Tabelle Fehlerdiagnose
Anzeige-LED / Fehlerbild /
LED indicator/fault pattern
Ursache /
Cause
Maßnahme /
Measures
grüne LED leuchtet nicht /
Green LED does not light up
keine Spannung oder Span‐
nung unterhalb der Grenzwer‐
te /
No voltage or voltage below
the limit values
Spannungsversorgung prüfen,
den gesamten elektrischen
Anschluss prüfen (Leitungen
und Steckerverbindungen) /
Check the power supply,
check all electrical connecti‐
ons (cables and plug connecti‐
ons)
12
9
8012134.10DT | SICK
Subject to change without notice
Other manuals for WTB4S-3
3
Table of contents
Languages:
Other SICK Accessories manuals

SICK
SICK OD1000 User manual

SICK
SICK GTE6L Series User manual

SICK
SICK LFP Inox User manual

SICK
SICK LFP Inox User manual

SICK
SICK WL12G-3P3572S12 User manual

SICK
SICK MultiPulse WTB4-3P2100S13 User manual

SICK
SICK WTF26 User manual

SICK
SICK HTB18 User manual

SICK
SICK deTec4 Core User manual

SICK
SICK GLS100 User manual

SICK
SICK RMS3 Series User manual

SICK
SICK DT50-2 Pro User manual

SICK
SICK MZT6-03VPS-KPX User manual

SICK
SICK LFV 200 User manual

SICK
SICK GTB20 User manual

SICK
SICK SIM1004 User manual

SICK
SICK Bluetooth WLA16 User manual

SICK
SICK CS81-P3612S02 User manual

SICK
SICK DL1000 User manual

SICK
SICK LFV 330 User manual