Sharp FP-F40A User manual

ENGLISH
中文
FP-F40A
R
AIR PURIFIER
OPERATION MANUAL
空氣清新機
使用說明書
Free standing type
直立型號
“Plasmacluster” and “Device of a cluster of grapes” are
trademarks of Sharp Corporation.
*The number in this technology mark indicates an
approximate number of ions supplied into air of 1 cm3,
which is measured around the center of a room with
the “high-density plasmacluster 7000” applicable oor
area (at 1.2 m height above the oor) at the medium
wind volume in air purifying mode, when an air purier
using the high-density plasmacluster ion evolving
device is placed close to a wall. This product is
equipped with a device corresponding to this capacity.
OM_FP-F40A_EN.indd 1 2015/10/20 8:47:28

NOTE
The air purier draws in room air from the air intake, passes the air through a Pre-
Filter, a Active Carbon Deodorizing Filter and a HEPA Filter inside of the unit, then
discharges the air through the air outlet. The HEPA Filter can remove 99.97% of dust
particles as small as 0.3 microns that pass through the lter.
The Active Carbon Deodorizing Filter gradually absorbs odors as they pass through
the lter.
Some odors absorbed by the lters may break down over time, resulting in additional
odor. Depending on the usage environment, especially when the product is used in
extreme environments (significantly more severe than normal household use), this
odor may become strong in a shorter period than expected. If the odor persists, the
lters should be replaced.
• The air purier is designed to remove air-suspended dust and odor, but not harmful gases (for
example, carbon monoxide contained in cigarette smoke).
Please read before operating your new Air Purier
HEPA Filter
Active Carbon
Deodorizing Filter
Back Panel
(Pre-Filter)
OM_FP-F40A_EN.indd 2 2015/10/20 8:47:29

ENGLISH
E-1
ENGLISH
Thank you for purchasing the SHARP
Air Purier. Please read this manual carefully.
Before using this product, be sure to read the
section: “Important Safety Instructions.”
After reading this manual, keep it in a
convenient location for future reference.
For your reference, we recommend to keep
this manual in the place where you can read
at any time.
IMPORTANT SAFETY INSTRUCTIONS
.....E-2
PART NAMES...............................................E-4
FILTER INSTALLATION .............................E-5
OPERATION .................................................E-6
CARE AND MAINTENANCE .....................E-8
TROUBLESHOOTING ..............................E-10
SPECIFICATIONS...................................... E-11
CONTENTS
FEATURES
Unique Combination of Air Treatment
Technologies
Triple Filtration System + Plasmacluster
Ions
TRAPS DUST*
Pre-lter traps dust and other large
airborne particles.
REDUCES ODORS
Active Carbon Deodorizing lter absorbs
many common household odors.
REDUCES POLLEN & MOLD*
HEPA lter traps 99.97% of particles as
small as 0.3 microns.
FRESHENS
Plasmacluster treats the air similar to the
way nature cleans the environment by
emitting a balance of positive and negative
ions.
*When air is drawn through the lter
system.
Sensor Technology continuously monitors
air quality, and automatically adjusting
airow based on detected air purity.
OM_FP-F40A_EN.indd 1 2015/10/20 8:47:29

E-2
IMPORTANT SAFETY INSTRUCTIONS
When using electrical appliances, basic safety precautions should be followed,
including the following:
WARNING - To reduce the risk of electric shock, re or injury to persons:
• Read all instructions before using the unit.
• Use only a 220 volt outlet.
• Do not use the unit if the power cord or plug is damaged or the connection to the
wall outlet is loosened.
•Periodically remove dust from the power plug.
• Do not insert ngers or foreign objects into the intake or air outlet.
• When removing the power plug, always hold the plug and never pull the cord.
Electric shock and/or re from short circuit may occur as a result.
•Be careful not to damage the power cord, it may cause electric shock, excess heat or
res.
• Do not remove the plug when your hands are wet.
• Do not use this unit near gas appliances or replaces.
• Remove the power plug from the wall outlet before cleaning the unit and when not
using the unit.
Electric shock from bad insulation and/or re from short circuit may occur as a result.
•When cleaning the unit, or when the unit is not in use, be sure to unplug the unit. Electric
shock and/or re from a short circuit may result.
• If the power cord is damaged, it must be replaced by the manufacturer, its service
agent, Sharp Authorized Service Centre or similarly qualified person in order to
avoid a hazard.
•Do not operate when using aerosol insecticides or in rooms where there is oily residue,
incense, sparks from lit cigarettes, chemical fumes in the air or in very high humidity
conditions, such as a bathroom.
•Be cautious when cleaning the unit. Corrosive cleansers may damage the exterior.
•Only a Sharp Authorized Service Centre should service this air purifier. Contact the
nearest Service Centre for any problems, adjustments, or repairs.
• This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless they
have been given supervision or instruction concerning use of the appliance by a person
responsible for their safety. Children shall not play with the appliance. Cleaning and user
maintenance shall not be made by children without supervision.
NOTE - Radio or TV Interference
If this air purier should cause interference to radio or television reception, try to correct the
interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the unit and radio/TV receiver.
• Connect the equipment into an outlet on a circuit dierent from that to which the receiver
is connected.
• Consult the dealer or an experienced radio/TV technician for help.
OM_FP-F40A_EN.indd 2 2015/10/20 8:47:29

ENGLISH
E-3
CAUTIONS CONCERNING OPERATION
• Do not block the air intake and/or air outlet.
• Do not use the unit near or on hot objects, such as stoves or heaters or where it may
come into contact with steam.
• Do not lay the unit down when using.
• Always hold the handle on the back of the unit when moving it.
• Do not use without the lters installed inside the unit.
•Do not wash and reuse the HEPA lter and the Active Carbon Deodorizing lter.
Not only does it not improve lter performance, it may cause electric shock or malfunction.
INSTALLATION GUIDELINES
•
When using the unit, place it away from equipment utilizing electric waves such as
televisions or radios to avoid electrical interference.
• Avoid using in locations where furniture, fabrics or other items may come in
contact with and restrict the air intake and/or air outlet.
• Avoid using in locations where the unit is exposed to condensation or drastic
temperature changes. Appropriate condition is at room temperature 0 – 35 ºC.
• Place on a stable surface with sucient air circulation.
When placing the unit on a heavily carpeted area, the unit may vibrate slightly.
• Avoid locations where grease or oily smoke is generated.
The unit surface may crack as a result.
•Place the unit about 30 cm(1 ft) away from the wall in order to ensure proper
airow.
The dust collecting performance will be the same even if using the unit 3cm away from
the wall, but place it as far as possible(30cm away recommended) because it may dirty
the wall or oor around.
FILTER GUIDELINES
• Follow the instructions in this manual for correct care and maintenance of the lter.
OM_FP-F40A_EN.indd 3 2015/10/20 8:47:29

E-4
PART NAMES
18
17
2
1
1Main Unit 10 Dust sensor / Dust Sensor Filter
2Air Outlet 11 HEPA Filter
3OFF TIMER Button /
LIGHT ON/OFF Button (Press 3 sec.) 12 Active Carbon Deodorizing Filter
4
MODE Button / MODE Indicator Light
(green)
Plasmacluster Ion ON/OFF Button
(Press 3 sec.)
13 Upper Tabs
5CLEAN ION SHOWER Button / CLEAN ION
SHOWER indicator Light (green) 14 Back Panel (Pre-Filter)
6POWER ON/OFF Button 15 Bottom Tabs
7DUST SIGN 16 Power Cord
8PLASMACLUSTER SIGN 17 Plug
9Handle 18 Date Label
FRONT
BACK
16
13
14
8
7
3 4 5 6
9
10
11
12
15
DUST SIGN
Indicates the air purity of the room
in 3 levels with color changes.
Green Clean
Impure
Orange
Red
PLASMACLUSTER SIGN
Blue Plasmacluster ON
O Plasmacluster OFF
OM_FP-F40A_EN.indd 4 2015/10/20 8:47:29

ENGLISH
E-5
FILTER INSTALLATION
To maintain the quality of the lter, it is installed in the main unit and packed in plastic
bag. Be sure to remove the lter from the plastic bag before using the unit.
1
Remove the Back Panel.
2Remove the plastic bag and
take out the Filter.
3
Place the Filter inside the main
unit.
Do not install the lter backwards or the
unit will not operate properly.
Upper Tabs
• Do not operate the unit without the lter.
Date Label
Pull Push
Push
Be sure to remove the power plug
from the wall outlet.
4Replace the Back Panel to the
main unit.
5Fill in the usage start date on the
Date Label.
Use the date as a guide for the lter
replacement schedule.
Bottom Tabs
HEPA Filter
Active Carbon
Deodorizing Filter
OM_FP-F40A_EN.indd 5 2015/10/20 8:47:30

E-6
OPERATION
AUTO SLEEP MED MAX
CLEAN AIR
START
• Select the desired fan speed.
• Unless the power cord has been unplugged,
the operation starts in the previous mode it
was operated in.
STOP
FAN SPEED
SLEEP
• The unit will operate very quietly, and the fan speed
is automatically switched depending on the amount of
impurities in the air.
DUST/PLASMACLUSTER SIGN go o automatically.
Even though the indicator is o, Plasmacluster Ion is
released into air unless Plasmacluster Ion is turned o by
NOTE
AUTO
• The fan speed is automatically switched depending on the
amount of impurities in the air. The sensors detect impurities
for efcient air purcation.
Releases high-density Plasmacluster ions and discharges strong air ow for 60 minutes.
CLEAN ION SHOWER
START
• If Plasmacluster Ion is OFF, Plasmacluster Ion will not be
released.
• When the operation nishes, the unit will return to the prior
operation mode.
It is able to change the other mode or turn o during this
mode.
NOTE
OM_FP-F40A_EN.indd 6 2015/10/20 8:47:31

ENGLISH
E-7
Light Control
Plasmacluster Ion ON/OFF
You can turn OFF the DUST/PLASMACLUSTER SIGN when they are lighting up.
● 2h ● 4h ● 8h CANCEL
ON
more than 3 sec.
OFF
• When the unit starts operation,
the DUST/PLASMACLUSTER
SIGN always light up.
• In SLEEP mode, Light Control
button doesn’t operate.
NOTE
When Plasmacluster Ion is ON, the PLASMACLUSTER SIGN will turn on. (blue)
(In operation)
ON OFF
ADJUSTMENT OF SENSOR DETECTION SENSITIVITY
Set to “Low” if the DUST SIGN is constantly red to reduce sensitivity, and set to “High” if the DUST
SIGN is constantly green to increase sensitivity.
OFF TIMER
Select the time turning o the unit during operation. The unit automatically stops once the selected
time is reached.
• If the Power ON/OFF Button is
not pressed within 8 seconds of
adjusting sensor sensitivity, the
setting will be saved automatically.
• The sensor sensitivity setting
will be saved even if the unit is
unplugged.
NOTE
1
2
3
(with the unit OFF)
High
Standard
Low
more than 3 sec.
more than 3 sec. more than 3 sec.
more than 3 sec.
Select the
sensor detection
sensitivity.
OM_FP-F40A_EN.indd 7 2015/10/20 8:47:32

E-8
Gently remove dust from the back panel by using
a vacuum cleaner attachment or similar tool.
BACK PANEL (Pre-lter)
To maintain optimum performance of this air purier, please clean the unit including the lter
periodically.
Be sure to disconnect the power cord from the wall outlet before performing any maintenance.
CARE AND MAINTENANCE
FILTERS
SENSOR
Dust sensor lter
Tag
HEPA Filter
Active Carbon Deodorizing Filter
CAUTION
Do not apply excessive pressure when scrubbing
the back panel.
CAUTION
1. Remove the Back Panel.
2. Remove the Dust Sensor Filter.
3. If it is very dirty, wash it with water and dry it
thoroughly.
Gently remove dust from HEPA Filter and Active Carbon Deodorizing
Filter with a vacuum cleaner attachment or similar tool.
Do not WASH in water and DRY in the sun.
The lters are fragile, be careful not to apply too much force.
• HEPA Filter
Apply the maintenance only on the side with the tag.
Do not clean the opposite side; otherwise, the lter will be
damaged.
• Active Carbon Deodorizing Filter
The maintenance can be applied to the both sides.
Back Panel
NOTE How to clean stubborn dirt
1. Add a small amount of kitchen detergent to water and soak
for about 10 minutes.
2. Rinse o the kitchen detergent with clean water.
3. Completely dry the lter in a well-ventilated area.
Back Panel
OM_FP-F40A_EN.indd 8 2015/10/20 8:47:32
This manual suits for next models
1
Table of contents
Other Sharp Air Cleaner manuals

Sharp
Sharp FP-K50U User manual

Sharp
Sharp KC-D61R User manual

Sharp
Sharp UA-HD40E User manual

Sharp
Sharp FXJ80UW User manual

Sharp
Sharp Plasmacluster KC-860U User manual

Sharp
Sharp FU-S51A User manual

Sharp
Sharp KC-G61R User manual

Sharp
Sharp IG-A10EK-W Manual

Sharp
Sharp FU-60SE-P User manual

Sharp
Sharp HIGH-DENSITY 7000 User manual

Sharp
Sharp FP-J40E User manual

Sharp
Sharp FX-J80A User manual

Sharp
Sharp KC-F30TA Installation manual

Sharp
Sharp UA-PN1U User manual

Sharp
Sharp FZ-60SEF User manual

Sharp
Sharp FP-FM40E User manual

Sharp
Sharp FU-28H-S User manual

Sharp
Sharp FZ-Y30SFE Guide

Sharp
Sharp KC-F31R User manual

Sharp
Sharp KI-A60E User manual