Schwarzwald-Lab AP1207 User manual

Tabletop Air Purifier
INSTRUCTION MANUAL
CATALOG NUMBER
AP1207
Thank you for choosing SCHWARZWALD!
PLEASE READ BEFORE RETURNING THIS PRODUCT FOR ANY
REASON.
If you have a question or experience a problem with your SCHWARZWALD
purchase, go to www.schwarzwald-appliances.com
SAVE THIS MANUAL FOR FUTURE REFERENCE.

PRODUCT REGISTRATION
Staple your receipt to your manual.
You will need it to obtain warranty service.
Thank you for purchasing our
SCHWARZWALD product. This easy-to-
use manual will guide you in getting the
best use of your air purifier.
Remember to record the model and
serial numbers. They are on a label on
the rear.
Model number
Serial number
Date of purchase

SAFETY INFORMATION
SAFETY INFORMATION
SAFETY INFORMATION
IMPORTANT SAFETY INSTRUCTIONS
WARNING
When using electrical appliances, basic safety precautions
should be followed, including the following:
READ ALL INSTRUCTIONS BEFORE USE
1. Only use the air purifier as described in this manual.
2. To avoid fire or shock hazard, plug the appliance directly into a 220V AC
electrical outlet.
3. Remove all packaging material, including the plastic wrap over the filter before
use.
4. If the adapter, its cord, or plug is damaged it must be replaced by the
manufacturer. Do not attempt to use a substitute adapter as it could result in
hazard and/or injury. Contact customer service for further assistance.
5. Check the household voltage to ensure it matches the appliance’s rated
specification.
6. Do not let cord touch any hot surface and make sure that it does not hang over a
table edge or counter.
7. Place air purifier on a firm, flat, level surface.
8. Do not use this product on wet surfaces. This air purifier is not intended for use
in bathrooms, laundry areas and similar indoor locations.
Never locate air purifier where it may fall into bathtub or other water container.
9. Avoid exposure to direct sunlight.
10. Close supervision is necessary when any appliance is used by or near children.
11. To reduce the risk of electric shock, do not remove screws. Do not attempt to
repair or replace parts except for filters.
12. Unplug the appliance before cleaning it. Wipe it with a soft cloth.
13. Unplug the air purifier before removing the filter.
14. Do not immerse the appliance or the power cord in water or other liquids.
15. Do not use any detergents, glass or household cleaner, furniture polish,
gasoline, paint thinner or other solvent to clean any part of the air purifier.

16. If you spill any liquid on the unit, it can cause serious damage. Switch it off and
unplug immediately.
17. Do not block, cover or obstruct the air vents. Do not place anything on top of the
unit.
18. Do not run cord under carpeting. Do not cover cord with throw rugs,
runners, or similar coverings. Do not route cord under furniture or
appliances. Arrange cord away from traffic area and where it will not
be tripped over.
19. WARNING - To reduce the risk of fire or electric shock, DO NOT use
this air purifier with any solid-state speed control devices.
20. Do not use outdoors.
READ AND SAVE THESE
INSTRUCTIONS
HOUSEHOLD USE ONLY

SAFETY INFORMATION
WARNING
This appliance in not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning the use of the appliance by a person responsible
for their safety. Children should be supervised to ensure that they do not play with the
appliance.
This appliance can be used by children aged from 8 years and above and persons with reduced
physical, sensory or mental capabilities or lack of experience or knowledge if have been given
supervision or instruction concerning the use of the appliance in a safe was and understand the
hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall
not be made by children without supervision.
OPERATING CONDITION
The air purifier should be operated between a temperature range of 18°C (64°F) - 60°C
(140°F) and a Relative Humidity under 90%.
NOTE: Unit performance may be affected when in use outside of these operating
conditions.

SET UP & USE
PARTS & FEATURES
Air Quality Indicator light
Touch screen controls
Air vents
Partiele Sensor
•............................
AC Input Connection
Exterior housing
AC Power Adapter.
3-Stage HEPA Filter
(Replacement Part Model
Number: AF1)
Aromatherapy Sponges
Bottom Filter Cover

SET UP & USE
OPERATING INSTRUCTIONS
Before using the air purifier for the first time, remove all packaging material, including the
plastic bag the filter is wrapped in.
NOTE: Refer to CLEANING AND MAINTENANCE section of this manual for information on
how to access and install the filter.
Place the Air Purifier on a firm level surface with the controls facing upwards, making sure
nothing is obstructing the air flow on any side of the air purifier.
Plug the AC power adapter into the AC input connection located at the bottom rear of the
unit. Plug the AC adapter into the wall socket.
When the air purifier is plugged in, it will beep and the POWER O button will illuminate.
Tap the POWER O button on the air purifier to start the air purifier. The fan speed will set at
LOW.

SET UP & USE
CONTROL PANEL
MODEL AP1207
Press the SPEED button repeatedly to scroll though LOW, MEDIUM, HIGH and SLEEP
settings. When in sleep mode, the fan will operate at low speed. Only the On and the (^)
lights will be illuminated.
Press the LOCK S button for 3 seconds to turn on the child lock function. When the icon
flashes the child lock is activated so that the settings cannot inadver- tently be changed.
Press the LOCK button again to turn the child lock off. When the icons are illumi- nated, the
child lock function in not activated.
Press the TIMER (bu button to scroll through the number of hours (1H, 2H, 4H, 8H) and select the
number of hours for the air purifier to shut off.
|l REPLACE FILTER Indicator Light
After 2,000 hours of use, the REPLACE FILTER indicator light will flash and there will be an
audible beep. Replace the filter with a new one. Press the REPLACE FILTER indicator light for 3
seconds until the control panel lights illuminate and the unit will no longer make a beeping sound.
NOTE: Refer to CLEANING AND MAINTENANCE section of this manual for infomation on how to
access and install the filter.
To shut off the unit at any time, press the POWER (J) button until all indicator lights to OFF.

SET UP & USE
CONTROL PANEL
MODEL AP1207
Press the SPEED & button repeatedly to scroll though LOW, HIGH, AUTO and SLEEP
settings. In AUTO mode, the fan speed is automatically set according to the air quality in the
in room. When in sleep mode, the fan will operate at a lower speed. Only the and the 0
lights will be illuminated.
Press the LOCK button for 3 seconds to turn on the child lock function. When the icon
flashes the child lock is activated so that the settings cannot inadvertently be changed.
Press the LOCK button again to turn the child lock off. When the icons are illuminated, the
child lock function in not activated.
Press the TIMER button to scroll through the number of hours (1H, 2H, 4H, 8H) and select the
number of hours for the air purifier to shut off.
REPLACE FILTER Indicator Light
After 2,000 hours of use, the REPLACE FILTER indicator light will flash and there will be an
audible beep. Replace the filter with a new one. Press the REPLACE FILTER indicator light
for 3 seconds until the control panel lights illuminate and the unit will no longer make a beeping
sound.
NOTE: Refer to CLEANING AND MAINTENANCE section of this manual for information on how
to access and install the filter.
To shut off the unit at any time, press the POWER button until all indicator lights to OFF.

SET UP & USE
AIR QUALITY INDICATOR LIGHTS
MODEL AP1207
This model has indicator lights which will change color according to the air quality detected
by the particle sensor.
Color of light
Blue
Green
Purple
Red
Air Quality
Excellent
Good
Fair
Poor
The air quality indicator lights will not glow when the air purifier is in sleep mode.
OPTIONAL AROMATHERAPY
Your air purifier comes with 2 sponges located on the bottom filter cover that allows you to add
essential oils (not included). If you wish to add fragrance to the air, moisten the sponges and add a
drop of the essential oil fragrance of your choice on to each sponge.
The fan will disperse the fragrance in the air through the air vents.
Table of contents