Schartec Move 600 User manual

English
Installation and operating instructions
S/N
Move 600 600N
Move 1000 1000N
Move 1200 1200N
600N
Move 600-Speed
Move 1000-Speed 1000N
26

Contents
Important Safety Instructions...........……………………………....……………………………..28
Warranty Conditions.............................................................................................................31
Product Description & Features............................................................................................32
Pre-Installation Recommendations.......................................................................................33
Installation Instructions..........................................................................................................35
- Boom Rail Assembly
-Mounting Wall and Door Brackets
-Installing the Boom Rail and Opener
Programming Instructions....................................................................................................39
External control and accessories connections.....................................................................42
Manual Disengagement.......................................................................................................43
Technical Specifications....………………………………………………………………….........44
Parts Listing……………………......…………….....................................................................46
Common Faults & Solutions.................................................................................................47
WARNING
Please read the manual carefully before you begin the installation and use of the opener. The
installation of your new garage door opener must be performed by a competent expert or a specialist
company. A competent person is, in accordance with EN 12635, considered a person who has
appropriate training, qualified knowledge and practical experience in order to mount and maintain a
door system properly and safely. The installation or repair without technical qualifications can lead to
property damage, serious injury, and/or death.
Package Contents.................................................................................................................34
Instructions for shortening the Boom Rail.............................................................................49
27

Important Safety Instructions
1. Intended Use:
The garage door opener is designed exclusively for impulse operation of spring-balanced Sectional and Up & Over garage doors
in private / non-commercial operations. Door systems used in a public area have only one protective device, e.g. the force limiter,
and may only be operated under supervision. The garage door opener is designed for operation in dry rooms only.
2. Unintended Use:
The garage door opener must not be used for purposes other than for the automation of garage doors. Continuous operation and
the use in the commercial sector is not permitted. The opener must not be used with doors without fall protection.
3. Qualifications of the fitter and installer
Proper fitting and maintenance should only be done by a competent / specialist company or a competent / qualified person in
accordance with the instructions that can ensure the safe and flawless operation of the assembly. A competent person is, in
accordance with EN 12635, considered a person who has appropriate training, qualified knowledge, and practical experience in
order to mount a door system properly and safely.
4. Safety instructions for installation, repair, maintenance, and disassembly of the door system DANGER!
Compensation springs are under high tension
The adjusting or loosening the compensating springs can cause serious injuries! If necessary, maintenance and repair work must
be made by a trained door system technician only! Never attempt to replace, readjust, repair, or move the balancing spring for the
counterbalancing of the door or their holders. Inspect that the entire door system (pivots, door bearings, ropes, springs and
fastenings) for wear and possible damage. Check them for signs of rust, corrosion and cracks. Error in the door system or
misaligned doors can cause severe injury! Do not use the door system if repair or adjustment work needs to be done!
Mains Voltage
Danger! Risk of electrocution upon contact with the mains voltage. Therefore please note, the following instructions: Electrical
connections may only be performed by a qualified electrician. Electrical installation on site must comply with the relevant safety
regulations (230/240 V AC, 50/60 Hz).
Disconnect the opener from the mains before performing any opener service.
Dear Customer
Thank you for choosing a quality product from Schartec. Thanks to our unique quality management system, we continuously
ensure that all Schartec openers meet the highest standards of quality and comfort. Thank you for your confidence in
purchasing our product and we hope you enjoy your new Schartec garage door opener!
Declaration of Conformity (CE)
Schartec Move series garage door openers meet the requirements of the applicable European and national guidelines.
Compliance was demonstrated that corresponding declarations, certificates, test reports and documents have been obtained by
the manufacturer and can be requested via www.schartec.de/en/. The FST-03 radio equipment type (Art.No.ST104032)
complies with Directive 2014/53 / EU. The full text of the EU Declaration of Conformity is available at the following Internet
address: www.schartec.de/en/
28

WARNING!
Non-suitable fastening materials
Use of unsuitable fixing materials can result in the opener not being securely attached and can become loosened. The supplied
mounting materials must be checked for their suitability for the intended installation location by the installer.
Fatal injury from hand rope
A guided type hand rope (pull cord) may lead to strangulation. Remove the pull rope/cord upon installing the opener.
Risk of injury from unintentional door movement
Improper installation or handling of the opener can trigger unwanted door travel and can result in people or objects being
pinched resulting in serious injury or death. Follow all instructions contained in this manual. Any incorrectly mounted control
devices (such as push buttons) can unintentionally trigger door travel resulting in persons or objects becoming pinched. Control
devices must be mounted at a height of at least 1.5 m (away from children). Assemble fixed control devices (such as push
buttons) within sight of the door but away from moving parts.
Risk of injury due to unexpected door travel
Installation, maintenance, repair, and dismantling of the opener and the garage door must be carried out by a specialist(s).
Upon failure of the garage door opener, directly entrust an expert with the inspection or repair.
Safety advice for mounting
The specialist must ensure that, in carrying out the installation, the applicable regulations regarding occupational safety and
those governing the operation of electrical equipment are complied with. National guidelines must therefore be observed.
Possible hazards, as defined in DIN EN 13241-1, are prevented by the design and installation according to our
specifications. The garage ceiling must be designed so that a secure attachment of the opener system is ensured. If ceiling
material is too high or too lightweight, then the opener system must be attached to additional safety/security braces.
CAUTION!
Crushing Risk by Boom Rail Mounting
When assembling the boom rail, there is a danger that fingers can be caught. Take care not to get your fingers caught between
the profile ends.
Pinching Risk in the Boom Rail
Grasping with fingers into the boom rail while the door is moving may cause pinching. Grasp only when the door is not moving
on the boom rail.
5. Safety information for commissioning and operation
CAUTION!
Pinching Risk in the Boom Rail
Grasping with fingers into the boom rail while the door is moving may cause pinching. Grasp only when the door is not moving
on the boom rail.
Risk of injury by pull cord
If you hang from the cord knob, the door can crash down and you may become injured. The opener could become dislodged
and injure people underneath, damage or even destroy objects. Do not hang from the pull cord.
WARNING!
Risk of injury by rapidly closing door
If the pull cord knob is pulled while the door is open, there is a risk that the door could close quickly because of weak, broken,
or defective springs or due to faulty counterbalance mechanism. The pull cord should only be pulled while the door is closed.
29

Risk of injury during door movement
While the door is moving, the risk of injury to persons or damage to objects is increased while standing in the movement area of
the door. Keep door opener system and remote controls out of reach of children. Ensure that when the door is moving that no
persons or objects are located within the door movement area. Only use the garage door opener when you have view of the
garage door itself and can monitor its movement. Monitor the door travel until the door has reached the end position. Drive or
pass through the garage door entryway ONLY when the door has come to a standstill! Never stand directly under the open door.
Proper Use
Demonstrate to all persons using the door opener system the proper and safe operation of the garage door opener. Demonstrate
and test the mechanical release as well as the safety return.
6. Precautions for the use of the remote control
WARNING!
Risk of injury from unwanted or accidental door movement
Accidental pressing of a button on the remote control can lead to unwanted door movements and lead to accidental injury. Make
sure that remote controls are not accessible to children and are only used by persons who have been instructed in the operation
of the remote-controlled garage door opener system! Only use the remote when you are in visual contact with the door unless a
safety device is connected (e.g. photocell). Drive or pass through the garage door entryway ONLY when the door has come to a
standstill! Never stand directly under the open door. Note that the accidentally pressing a key on the remote (for example in your
pocket / handbag) may lead to an unwanted door travel.
7. Safety Installations
Safety-related functions and components such as automatic power shutdown and the use of external photocells have been
tested and meet the requirements of EN 12453 and EN 12445 standards.
WARNING!
Risk of injury from malfunctioning safety devices
To test the safety reverse, hold the door as it closes with both hands. The garage door opener system must stop and initiate the
safety reverse. Test this also as the garage door opens. The door system must switch off and stop the door movement. Upon
failure of the security reverse, directly entrust an expert with the inspection or repair.
8. Inspection and maintenance
The garage door opener is maintenance-free. According to the manufacturer and for your own safety, we recommend that you
allow the garage door opener system to be inspected by an expert. A check or a necessary repair should only be performed by a
specialist. Please also contact your supplier. A visual inspection may be carried out by the user. Check all safety and security
features on a monthly basis. Existing errors or defects must be rectified immediately. Inspect the tension of toothed belt every six
months and adjust accordingly if necessary. During the opening and closing phase, the belt may loll briefly because of rail
profile. However, this effect does not have any technical losses and also does not adversely affect the function and life of the
belt.
30

Warranty
We are exempt from the warranty and product liability if the opener has been modified without our prior consent or
improper installations are performed or initiated against our assembly instructions. Furthermore, we assume no
responsibility for the inadvertent or negligent operation of the opener, as well as for the improper maintenance of the
opener and accessories, nor for the improper maintenance of the door and its counterbalance mechanism. Batteries, light
bulbs, and LEDs are also excluded from the warranty claims.
Duration of Warranty
In addition to the legal guarantee of the dealer from the purchase contract, we provide the following warranty from date of
purchase:
•3 Years
•2 Years on radio and accessories
The warranty time is not extended a using warranty claim. For replacement deliveries and rectification work, the warranty
period is six months or at least the remainder of the warranty period.
Conditions
The warranty applies only to the country where the product was purchased. The product must have been purchased
through our authorized distribution channels. The warranty only covers damage to the contractual item itself.
Reimbursement of expenditure for dismantling and installation, testing of corresponding parts, as well as demands for lost
profits and damages are excluded from the guarantee. The receipt of purchase serves as proof of warranty.
Performance
For the duration of the warranty, we shall resolve any defects of the product which are demonstrably attributable to a
material or manufacturing defect. At our discretion, we shall, free of charge, replace the defective product for a non-
defective, repair or refund a diminished value. Excluded are damages caused by:
•Improper installation and connection
•Improper commissioning and operation
•External influences such as fire, water, abnormal weather conditions
•Mechanical damage due to accidents, dropping or shock
•Negligent or deliberate destruction
•Normal wear and tear or poor maintenance
•Repair by unqualified persons
•Use of non-original parts
•Removal or obscuring of the serial number
•Replaced parts become property of the manufacturer
Warranty Conditions
31

1. Automatic safety reverse
Automatic stop / automatic reverse are controlled by the software on our circuit boards. We are cautious to
protect your children, pets, and property.
2. Soft start / Soft stop
Gently ramping speed up and down at the start and end of each cycle reduces stress on the door and
opener, and makes for longer life and quieter operation of the motor.
3. Auto-Close (Photocell required)
Auto-Close ensures peace of mind and keeps your house secure by automatically closing the door after entering or
exiting the garage.
4. Self learning - opening and closing forces
Teaching in the open and close limits of your garage door is simple with the self-learning function. The opener
"learns" the amount of force required at each stage of opening and closing of your door.
5. Simple adjustment of the end positions
Setting the end positions is easily done by pressing a button on the display panel.
6. Terminals for Accessories
Terminals are available for photocells (safety beam), wired or wireless wall switches, caution/warning lights, and key
switches.
7. Energy saving LED
The courtesy LED light has a 3 minute delay, switching on with each cycle to illuminate your darkened garage.
8. Self-Locking gear motor
Schartec gear motors will self-lock with our disengagement systems.
9. Manual release
Don't worry about power failure, the manual release system allows you to open the door at any time.
10. Transmitter technology
With Rolling-Code technology (7.38 x 1019 Combinations) and 433.92 MHz frequency, the 4 channel remote control
design ensures that you can control 4 different Schartec Move motors with one remote.
11. Lower headroom
With as little as 30mm required between the ceiling and the highest point of the door travel, the opener can be flush
mounted for low headroom applications.
12. Metal bottom plate, stronger and more secure
13. Open/Stop/Close - button (A)
Front panel open / stop / close buttons for operation. (see below)
14. External mains power fuse (B) (see below)
A
B
Product Description & Features
32

Pre-Installation Recommendations
1. Check the garage door and garage door system
DANGER!
Balancing springs are under high tension. The readjustment or loosening of the balancing springs can cause serious injuries! For
your own safety, necessary maintenance and repair work of the balancing springs should only be performed by an expert. Never
attempt to replace, readjust, repair, or move the balancing springs for the counterbalancing of the door or their holders. Check the
entire door system (pivots, door bearings, ropes, springs and fastenings) for wear and possible damage. Check them for signs of
rust, corrosion and cracks. Error in the door system or misaligned doors can cause severe injury! Do not use the door system if
repair or adjustment work needs to be done!
The construction of the opener is not designed to operate sluggish doors, i.e. doors that can no longer or hardly be manually
opened or closed. The door must be in a mechanically healthy state that is easy to operate by hand (EN12604). Open the
garage door approximately half way and let go. The door should maintain this position and move neither up nor
down. If the door moves in either direction, then there is the risk that either the balancing springs/weights are not properly
adjusted or defective. In this case, increased wear and malfunctioning of the door is expected. Check that the door can open and
close correctly. Disengage/Remove any mechanical locks that may be on the door -- they are not needed with the use of
the garage door opener. These include in particular the locking mechanisms connected with the door. For installation and
commissioning, check the illustrated section. Take note of the text in the appropriate sections.
2. Required Clearance
The clearance between the highest point of the door travel and the ceiling must be at least 30 mm. For a lower clearance height,
and if space is available, the opener can be mounted behind the opened door. In these cases, an extended door link must be
used and may be purchased separately. The necessary electrical outlet for the electrical connection should be mounted within
approx. 50 cm from the opener (refer to the electrical mains chapter).
Check these dimensions!
Important note: As an additional safety device, the use of a photocell (safety beam) is recommended (sold separately).
3. Emergency release
For garages without a second entrance, an emergency release for the mechanical release is necessary to prevent getting locked
in the garage in the event of power failure. The emergency release is door-specific and must be ordered separately.
Check the function of the emergency release monthly.
Figure 1
33

Package Contents
*Mounting screws and Anchors for the Door and Wall brackets are not included in the package.*
34

Installation Instructions
Boom Rail Assembly
3 Part Boom Rail
2 Part Boom Rail
A:1500 mm
B:1500 mm
Sleeve
C:1000 mm
Sleeve
Sleeve
D:1000 mm
E:1000 mm
Figure 2
Figure 3
1. 2-Part Rail
First, align the 3 parts in a row on the floor like in Figure 2. Remove the trolley piece with the straight
arm piece. Slide the belt wheel with the screw rod along with the belt through all 3 parts, but not
completely to the end. Before putting part A and B into the sleeve, place the trolley with the straight
arm piece into the rails with the straight arm piece being placed in first into part B. Now slide part A
and B into the sleeve until the notch fits into the groove on both parts. Pull the belt wheel with the
screw rod to the end of the rail.
3-Part Rail
The assembly is the same as the 2-Part Rail with the addition of the 2nd sleeve part.
Check out our assembly video by scanning this QR code with your smartphone!
or visit www.schartec.de/en/
35
Other manuals for Move 600
1
This manual suits for next models
7
Table of contents
Other Schartec Door Opening System manuals
Popular Door Opening System manuals by other brands

Normstahl
Normstahl IDO7 installation manual

Häfele
Häfele Finetta T 70 VF manual

AGS
AGS D-PL Instructions for fitting, operating and maintenance

Stanley
Stanley MA900ñ Installation and owner's manual

WITTUR
WITTUR Hydra Plus UD300 Instruction handbook

Alutech
Alutech TR-3019-230E-ICU Assembly and operation manual