Satel GREY User manual

GREY / GREY Plus
Digital dual technology motion detector
EN
Firmware version 1.3 grey_en 06/21
SATEL sp. z o.o. •ul. Budowlanych 66 • 80-298 Gdańsk • POLAND
tel. +48 58 320 94 00
www.satel.eu

IMPORTANT
The device should be installed by qualified personnel.
Prior to installation, please read carefully this manual.
Changes, modifications or repairs not authorized by the manufacturer shall void your rights
under the warranty.
SATEL aims to continually improve the quality of its products, which may result in changes in
their technical specifications and software. Current information about the changes being
introduced is available on our website.
Please visit us at:
https://support.satel.eu
The declaration of conformity may be consulted at www.satel.eu/ce
The following symbols may be used in this manual:
- note,
- caution.

CONTENTS
1. Features ...........................................................................................................................2
2. Description........................................................................................................................2
Anti-mask feature [GREY Plus] ........................................................................................2
Supervision features.........................................................................................................2
LED indicator....................................................................................................................2
Alarm memory ..................................................................................................................3
3. Electronics board..............................................................................................................3
4. Selecting a mounting location...........................................................................................4
5. Installation ........................................................................................................................5
6. Start-up and walk test.......................................................................................................8
Separate testing of sensors..............................................................................................9
Configuring the anti-masking settings...............................................................................9
7. Specifications .................................................................................................................10

2 GREY / GREY PLUS SATEL
The GREY / GREY Plus detector detects motion in the protected area. This manual applies
to the detector with electronics version H.
1. Features
Motion detection with two sensors: passive infrared sensor (PIR) and microwave sensor
(MW).
Adjustable detection sensitivity of both sensors.
Capability of separate sensor testing.
Digital motion detection algorithm.
Digital temperature compensation.
Pet immunity up to 15 kg.
Microwave based anti-mask feature [GREY Plus].
Built-in end-of-line resistors (2EOL: 2 x 1.1 k).
Bi-color LED indicator.
Remote LED enable / disable.
Alarm memory.
Supervision of motion detection system and supply voltage.
Tamper protection against enclosure opening.
2. Description
The alarm output will turn on for 2 seconds when the infrared sensor (PIR) and
the microwave sensor (MW) detect motion within a time period shorter than 5 seconds.
Anti-mask feature [GREY Plus]
Detection by the microwave sensor of an object moving at a distance of 10-20 centimeters
from the detector is interpreted as an attempt to mask the detector and causes the anti-mask
output to turn on for 5 seconds. Objects permeable to microwaves, but isolating the infrared
radiation are not detected by the anti-mask feature.
The anti-mask feature does not meet the EN 50131-2-4 requirements.
Supervision features
In the event of the voltage drop below 9 V (± 5%) for more than 2 seconds or the motion
detection system failure, the detector will signal a trouble. The trouble is indicated by the
alarm output turning on and the LED lighting up red. Signaling will continue as long as the
trouble exists.
LED indicator
The LED indicates:
warm-up –flashing red and green for about 35 seconds;
motion detected by microwave sensor –ON in green for 2 seconds;
motion detected by PIR sensor –ON in green for 2 seconds;
alarm –ON in red for 2 seconds;
alarm memory –flashing red;
trouble –ON in red for entire duration of the trouble.

SATEL GREY / GREY PLUS 3
Enabling the LED by using a jumper
If you put a jumper across the LED pins in ON position, the LED will be enabled, i.e. it will
indicate the events described above (the LED cannot be enabled / disabled remotely). If you
put a jumper across the LED pins in OFF position, the LED will be disabled, i.e. it will only
indicate warm-up and trouble (but the LED can be enabled / disabled remotely).
Remote LED enable / disable
The LED terminal is provided to allow remote LED enable / disable. When the terminal is
connected to common ground, the LED is enabled. When the terminal is disconnected from
common ground, the LED is disabled.
If the detector is used in the INTEGRA / INTEGRA Plus alarm system, you can connect to
the terminal the OC type control panel output programmed e.g. as “Zone test status” or “BI
switch”.
Alarm memory
If the LED is enabled, the detector can signal the alarm memory. The MEM terminal is
provided to allow the alarm memory enable / disable. The alarm memory is enabled, when
the terminal is connected to common ground. The alarm memory is disabled, when the
terminal is disconnected from common ground. If the alarm memory is enabled and an alarm
occurs, the LED will start flashing red. Indication of the alarm memory will continue until the
alarm memory is enabled again (the MEM terminal is connected to common ground).
Disabling the alarm memory will not stop the alarm memory indication.
If the detector is used in the INTEGRA / INTEGRA Plus alarm system, you can connect to
the MEM terminal the OC type control panel output programmed e.g. as “Armed status”.
3. Electronics board
Do not touch the pyroelectric sensor, so as not to soil it.
terminals:
AM - anti-mask output (NC relay) [GREY Plus].
NC - alarm output (NC relay).
TMP - tamper output (NC).
COM - common ground.

4 GREY / GREY PLUS SATEL
12V - power input.
LED - LED indicator enable / disable.
MEM - alarm memory enable / disable.
pins for configuration of the detector outputs. Available settings are shown in the figures:
2 –built-in resistors are used –connect the detector outputs as shown in Fig. 12 or 13.
3 –built-in resistors are not used –connect the detector outputs as shown in Fig. 11.
tamper switch.
microwave sensor.
fixing screw hole.
bi-color LED indicator.
PIR sensor (dual element pyrosensor).
pins for configuration of the detector:
PET –enable / disable the pet immunity option:
jumper in ON position –option enabled (Fig. 4).
jumper in OFF position –option disabled (Fig. 5).
LED –enable / disable the LED:
jumper in ON position –LED enabled (Fig. 4).
jumper in OFF position –LED disabled (Fig. 5).
potentiometer for adjustment of PIR sensor sensitivity.
potentiometer for adjustment of microwave sensor sensitivity.
When setting the sensitivity of the MW sensor, keep in mind that microwaves can
penetrate e.g. glass, plaster walls, non-metal doors, etc.
4. Selecting a mounting location
Do not install the detector outdoors (A).
Install the detector at the recommended height (B).
When choosing the installation location, keep in mind that the detector performance will
be the best where the expected direction of the intruder movement will be across the
coverage pattern (C).

SATEL GREY / GREY PLUS 5
Do not install the detector in places where it will be exposed to direct sunlight (D) or light
reflected from other objects (E).
Do not point the detector towards fans (F), air conditioners (G) or heat sources (H).
5. Installation
Disconnect power before making any electrical connections.
If the detector is to be pet immune, it must not be mounted on the bracket and
must be installed at a height of 2.4 m with no inclination from the vertical.
1. Remove the front cover (Fig. 6).
2. Remove the electronics board (Fig. 7).
3. Make the openings for screws (Fig. 8 and 9) and cable (Fig. 10) in the enclosure base.
4. Pass the cable through the prepared opening.
5. Secure the enclosure base to the wall (Fig. 8) or a bracket fastened with screws to the
wall or ceiling (Fig. 9). The wall plugs (anchors) delivered with the device are intended for
concrete, brick, etc. For other types of surface (drywall, styrofoam), use the appropriately
selected wall plugs.
6. Fasten the electronics board.
7. Connect the wires to the corresponding terminals.
8. Configure the detector settings.
Configure the anti-masking settings first (see “Configuring the anti-masking settings”).
If you change these settings after you have configured the microwave sensor
sensitivity, you will have to repeat the sensitivity configuration process.
9. Replace the cover.

6 GREY / GREY PLUS SATEL

SATEL GREY / GREY PLUS 7

8 GREY / GREY PLUS SATEL
6. Start-up and walk test
The LED indicator should be enabled during the walk test (see “LED indicator”).
1. Power on the detector. The LED will start flashing red and green to indicate warm-up of
the detector.
2. When the LED stops flashing, check if moving within the detector coverage area will make
the LED light up red. Figures 14 and 15 show the maximum coverage area of a detector
installed at a height of 2.4 m (Fig. 14 –pet immunity option disabled, Fig. 15 –pet
immunity option enabled).
Other manuals for GREY
1
This manual suits for next models
1
Table of contents
Other Satel Security Sensor manuals

Satel
Satel APD-100 User manual

Satel
Satel GRAPHITE User manual

Satel
Satel AQUA PET User manual

Satel
Satel TD-1 User manual

Satel
Satel VD-1 User manual

Satel
Satel AQUA S User manual

Satel
Satel AOD-200 User manual

Satel
Satel PDB-100 User manual

Satel
Satel AGD-100-BR User manual

Satel
Satel abax 2 ADD-200 User manual

Satel
Satel VD-1 User manual

Satel
Satel micra MXD-300 User manual

Satel
Satel abax 2 ACD-220 User manual

Satel
Satel COBALT User manual

Satel
Satel APMD-150 User manual

Satel
Satel AQUA RING User manual

Satel
Satel SLIM-PIR-PET User manual

Satel
Satel AFD-100 User manual

Satel
Satel AVD-100 User manual

Satel
Satel AOD-210 User manual