Rhima DEKO 260iX User manual

Rhima Australia
Tel: 03 8586 5444
www.rhima.com.au
WASHING EQUIPMENT
OPERATORS MANUAL
DEKO 260iX WASHER DISINFECTOR

2

TABLE OF CONTENTS
1SAFETY INSTRUCTIONS AND WARNINGS............................................................................ 4
2INTENDED USE OF THE MACHINE........................................................................................ 6
3STORAGE CONDITIONS ......................................................................................................... 8
4OPERATING CONDITIONS...................................................................................................... 8
5OPERATING INSTRUCTIONS ................................................................................................. 9
:DVKLQJDQGGLVLQIHFWLRQF\FOHV 9
6WDQGDUGF\FOHV'(.29
/DERUDWRU\F\FOHV'(.2/10
3URFHVVGLDJUDP1
9DOXHVRIWKHF\FOHV2
3URFHVVFKHPLFDOVDQGYDULDEOHV2
5HTXLUHPHQWVRQGHWHUJHQWLQ'HNRZDVKHUGLVLQIHFWRUV3
3URFHVVSDUDPHWHUV4
5HTXLUHGFRQGLWLRQV4
&RQWUROV5
2SHUDWLQJV\VWHPV5
9DULRXVUDFNVIRUYDULRXVORDGV6
6WDUWLQJDF\FOH7
86(5PRGH8
3URFHVVUHFRUGLQJ1
9LHZHU3
0DOIXQFWLRQDQGIDXOWV4
3DQHOSULQWHU6
3XUJHDQGGLVLQIHFWLRQ7
0HWKRGVRIFOHDQLQJ7
)OXVKLQJRIFKHPLFDOGRVLQJV\VWHPV8
6TESTING .................................................................................................................................29
7RECYCLING AND DISPOSAL INSTRUCTIONS......................................................................29
8DECLARATION OF CONFORMITY.........................................................................................30
9WARRANTY TERMS AND CONDITIONS................................................................................31
10APPENDIX I: FAULT LIST....................................................................................................33
11APPENDIX II: USER AND MAINTENANCE INSTRUCTIONS. .............................................35
3

6$)(7<,16758&7,216$1':$51,1*6
When using an electrical appliance, basic precautions should always be followed including the
following:
OPERATOR TRAINING
The responsible body shall ensure that all personnel who operate or maintain our machine are
trained in its operation and in its safe use. Furthermore to organize regular training of all
personnel concerned with the operation and maintenance of the machine.
READ ALL INSTRUCTIONS BEFORE USING THE MACHINE
WARNINGS
The manufacturer cannot be held responsible for damage caused when the appliance is not used
according to the instructions, or for uses other than those for which it was intended.
This special commercial machine is suitable for the applications mentioned in the operating
instructions. Use only for purposes machine was designed. The manufacturer cannot be held
responsible for damage caused by improper use.
Do not allow children or unauthorised personnel access to the machine or its controls.
The process needs to be checked and documented by authorised persons regularly. See EN ISO
15883-1, -2, and IEC 61010-2-040.
The cycles must not be interrupted, as it would cause danger and affect the cleaning and
disinfection result. If interruption occurs, do not make an attempt to open door and start the
process again. In case the fault condition occurs repeatedly, please call for service. In cases of
emergency e.g. fire or flooding, cut off the services to the machine using the safety controls
provided externally to the unit. The machine is completely isolated from the electricity supply only
when it is unplugged or the circuit breaker is turned off. This must be done before any repair work
is carried out.
The machine is constructed in accordance with current safety requirements. Any repairs shall
only be carried out by an authorised and a suitably qualified and competent engineer.
The electrical safety of this machine can only be guaranteed if connected to an electrical system
complying with all relevant regulations and checked by the regulating authority. The manufacturer
cannot be held responsible for damage caused by incorrect wiring.
Installation must be done by suitably qualified and competent contractor. Before connecting the
machine, the Installer shall check that the voltage and frequency of the electrical supply
correspond with the details on the data plate of the machine.
Only genuine Franke parts or accessories shall be used with the DEKO 260 Washer Disinfector.
The performance and safety of non-genuine parts or accessories cannot be guaranteed, and use
of such parts or items may void the machine warranty. If you have specific questions about
machine options or accessories, please call your supplier.
The water in this machine must not be used as drinking water.
Only use detergents recommended by Franke. Do not use solvents in your machine due danger
of explosion.
4

Take care when handling liquids such as detergents, rinsing or neutralising agents. These may
contain acids or alkalis. Follow the instructions and safety procedures on the packaging carefully
and wear protective gloves and goggles. Read the Material Safety Data Sheets.
Empty all containers and glassware before placing in machine. Do not allow any acids or
solvents, especially hydrochloric acid and chlorides, into the wash chamber.
Becarefulwhensortinginstrumentswithsharppointedends.Placethepointedenddownwards
if possible.
Install special inserts in accordance with the instructions provided.
When using the machine be careful not to scald or burn yourself. Baskets and inserts must first
be allowed to cool down. Water may have collected in incorrectly loaded items is very hot and
should be emptied into the wash chamber.
Do not touch the inner surfaces of the wash chamber or the heating elements after the end of
program. You could burn yourself.
Do not spray water on the machine.
Do not sit or lean on the open door. This can cause machine to tip and be damaged.
When disposing old machine, make sure the door catch is removed. This will prevent children to
be accidentally locked in.
Be careful when removing the panels and working inside the machine because of possible burrs
and sharp edges. Use safety gloves if possible.
The manufacturer cannot be held responsible for damage caused by failure to heed the warning
and safety instructions.
USED SAFETY SYMBOLS
Dangerous voltage
Door window is hot during washing and disinfection cycle.
Be aware of the steam discharge.
The goods and racks are hot to handle.
When you handle process chemicals - wear protection
gloves and follow the suppliers’ safety instructions.
5

,17(1'('86(2)7+(0$&+,1(
The DEKO 260 Washer Disinfector is suitable for automatic cleaning and thermal disinfection of
medical devices intended for re-use such as;
* Surgical instruments
* Instrument trays
* Instruments for minimum invasive surgery
* Rigid endoscopes
* Anaesthetic and respiratory equipment
* Hollowware
* Glassware and
* Transit containers
More information in standards:
- EN ISO 15883-1 Washer-disinfectors, Part1: General requirements, definitions and tests
- EN ISO 15883-2 Washer-disinfectors, Part2: Requirements and tests for washer-disinfectors
When processed in the instrument washer-disinfector, the medical devices may be intended for
immediate use or packed and sterilised. In both cases the efficacy of the cleaning and
disinfection is of major importance. In the first case this is for the well being of the patient, in the
latter case it is for the safety of the staff who handles the instruments in the process of
inspecting, testing and packing the instruments.
The efficacy of disinfection may be impaired if soil removal is incomplete before the start of the
disinfection process. Some medical devices may require pre-treatment e.g. soaking, brushing,
ultra sonic pre-cleaning, lumen irrigation or any combination of these techniques.
RESTRICTIONS IN USE
A number of medical devices are excluded from processing in a washer-disinfector altogether.
Always follow the Medical Device Manufacturer‘s instructions for reprocessing the particular item.
Re-usable medical devices including hazardous chemicals, gases, materials, parts, components
and/or constructions, which do not tolerate water treatment, spray washing and/or heat above
+55 Celsius degrees, disposable items, textiles & fabrics, wood, paper & pulp products, tissues
and dissolving plastics must not be processed in the DEKO 260 washer-disinfector. The DEKO
260 is not designed for the processing of thermo labile flexible endoscopes (covered in EN
ISO15883-1 and15883-4) or re-usable human waste containers (covered in EN ISO15883-1 and
15883-3), laundry or articles used for general catering purposes. DEKO 260 is not intended for
the sterilisation of the load as specified in other standards e.g. EN285.
6

Instruments suitable for processing in a thermal disinfector
All instruments, accessories, and other items to be cleaned and disinfected in the DEKO 260
Washer Disinfector should have the following properties:
- Heat resistant to a temperature of up to 138
0
C
- Corrosion resistance in the presence of heat and alkalinity
The high heat retention capacity of stainless steel allows for fast drying. Plastics and rubber have
a lower heat retention capacity, thus needing a longer drying time. In this case a machine with an
integrated drying unit and/or a separate drying cabinet is recommended.
Aluminium discolours. Aluminium only has a limited suitability for processing in this machine.
Carbon steel may corrode in the process. Please try the corrosion resistance of carbon steel
instruments with initially one instrument, or do not process carbon steel items at all.
Dental hand pieces, drill bits, grinders, root canal instruments or other rotating instruments only
have a limited suitability for the thermal disinfector. Please ask the manufacturer's advice on the
suitability for processing their items in this system.
Rhodium coated specula must be arranged so that their surfaces do not suffer any mechanical
damage. Not all specula with glass are suitable for machine treatment.
In case you have any questions regarding the suitability of instruments for being processed in the
DEKO 260 Washer Disinfector, please contact the instrument manufacturer for advice.
7

6725$*(&21',7,216
Ambient or room temperature 0
0
C-+50
0
C
Relative humidity, non-condensing 10-90 %
Max. storage time 1 year
Atmosphere Non-corrosive
23(5$7,1*&21',7,216
Electrical ratings
This machine is designed for
Voltage ratings: see 5.5 Electrical connections (Maintenance manual).
Pollution degree
- Pollution degree 2
Installation category
- Installation category II
Maximum relative humidity
80 % for temperatures up to 31
0
C
Operating temperature range
- 5
0
Cto40
0
C
Maximum altitude
- Up to 2000 m
Voltage fluctuation limits of the mains supply
-±10 % of the nominal voltage
Over voltage category
Category II (Note! 61010-1, second edition 2001-02 specifies over voltage categories only
for measuring equipment)
8

23(5$7,1*,16758&7,216
:DVKLQJDQGGLVLQIHFWLRQF\FOHV
6WDQGDUGF\FOHV'(.2
INSTRUMENT PROGRAM
P
hase
0
C
mm:ss
m
l
Rinse, cold water 01:00
Rinse, cold water 01:00
Wash with detergent 55 05:00 55
Rinse, warm water 55 02:00
Disinfection A
0
= 600 90 01:00
Drying 85 40:00
Approximate total time with heating 70:00
AN – PROGRAM
Phase
0
C
mm:ss
ml
Rinse, warmwater 45 02:00
Wash with detergent 55 07:00 55
R
inse, warm water
55 02:00
Disinfection A
0
= 600 90 01:00
D
rying
85 40:00
Approximate total time with heating 75:00
PLASTICS PROGRAM
P
hase
0
C
mm:ss
m
l
R
inse,
w
arm water
45 02:00
Wash with detergent 55 03:00 55
Rinse, warm water 55 02:00
Disinfection A
0
= 600 80 10:00
Drying 80 30:00
Approximate total time with heating 65:00
9

/DERUDWRU\F\FOHV'(.2/
SHORT LAB
Phase
0
C
mm:ss
ml
Rinse, warm water 45 2:00
Wash with detergent 55 7:00 55
Rinse, warm water 55 2:00
Rinse, warm water 55 2:00
Rinse, pure water 45 2:00
Approximate total time with heating 30:00
LONG LAB
P
hase
0
C
mm:ss
m
l
Rinse, warm water 45 2:00
Wash with detergent 55 10:00 55
Rinse, warm water 55 2:00
Rinse, pure water 45 2:00
Rinse, pure water 45 2:00
Approximate total time with heating 35:00
SHORT LAB ( INCL. DISINFECTION )
Phase
0
C
mm:ss
ml
Rinse, warm water 45 2:00
Wash with detergent 55 7:00 55
Rinse, warm water 55 2:00
Rinse, warm water 55 2:00
Disinfection, pure water 90 1:00
Approximate total time with heating 30:00
Remove unnecessary shelves and racks from the machine. Water valves in the wash chamber
are unnecessarily open decreasing water pressure.
10
Table of contents
Other Rhima Washer manuals

Rhima
Rhima RC231 User manual

Rhima
Rhima RR211 PRO User manual

Rhima
Rhima HIGH SPARKLE 40 User manual

Rhima
Rhima RR225 OPTIMA User manual

Rhima
Rhima RG 10 HR User manual

Rhima
Rhima RH 60 User manual

Rhima
Rhima RR108 COMPACT User manual

Rhima
Rhima RR190 EVO User manual

Rhima
Rhima DEKO 190iX User manual

Rhima
Rhima RM 50 User manual
Popular Washer manuals by other brands

Tricity Bendix
Tricity Bendix AW 1000 W Operating & installation instructions

Panasonic
Panasonic NA-F60L5WRB operating instructions

GE
GE WSLP1500 Dimensions and installation information

Electrolux
Electrolux EWF1284EDW Service manual

Bosch
Bosch WAN2829BSN User manual and installation instructions

LG
LG TV2516DV3B owner's manual