Regulus RDC Series User manual

www.regulus.eu
RDC Room Unit
RDC Room Unit
EN
Installation and Operation Manual
RDC Room Unit with Touchscreen

R E G U L U S spol. s r.o.
Do Koutů 1897/3, 143 00 Praha 4
Tel.: +420 241 764 506
E-mail: info@regulus.cz
www.regulus.cz
2 / 21
Obsah
Technical Description of the Room Unit ................................................................................................. 3
Wiring the Room Unit .............................................................................................................................. 3
Room Unit Simple Mode ......................................................................................................................... 4
Room Unit Display in Complete Mode .................................................................................................... 5
Control keys ......................................................................................................................................... 6
Initial displays in Complete Mode ........................................................................................................... 6
Basic display (room temperature) ....................................................................................................... 7
Mode selection display ........................................................................................................................ 8
Outdoor temperature display ............................................................................................................. 9
Immediate recirculation display ........................................................................................................ 10
Immediate ventilation display ........................................................................................................... 11
Temperature displays ........................................................................................................................ 12
Main menu in Complete Mode ............................................................................................................. 13
Heating zone settings (ZONE) ............................................................................................................ 13
DHW zone settings (DHW) ................................................................................................................ 15
Ventilation settings (VENT) ............................................................................................................... 16
Holidays function settings (HOLIDAYS) ............................................................................................. 17
Heat pump settings (HP) ................................................................................................................... 18
Solar heating settings (SOLAR) .......................................................................................................... 19
Auxiliary heat source settings (SOURCE) ........................................................................................... 19
Display of sensor values (INPUTS) ..................................................................................................... 19
Date and time settings (TIME)........................................................................................................... 20
Password reset for controller website access (WWW) ..................................................................... 21

R E G U L U S spol. s r.o.
Do Koutů 1897/3, 143 00 Praha 4
Tel.: +420 241 764 506
E-mail: info@regulus.cz
www.regulus.cz
3 / 21
Technical Description of the Room Unit
C-RC-0011R is a wall-mount room unit with one inner sensor and a touchscreen, designed as a
standard unit on a CIB bus.
The unit is intended for operation in normal and chemically non-aggressive environment. No
maintenance is required. It consists of 2 parts: bottom with terminals and a cover with PCB and
control screen. It shall be fitted onto a diam. 60 recessed electric box or on a wall. There is an
opening for cable in the bottom part.
The unit is fitted with a touchscreen where special symbols are controlled by the module's CPU. The
unit is equipped with 5 capacitive keys in the bottom part of the screen, permitting to scroll between
screens and edit displayed values.
The unit can be controlled using either a simple display mode (a LOCK icon is shown on the display)
or a complete display mode. The display mode and items shown in the complete display mode can be
selected on the service level of the controller’s web interface.
Wiring the Room Unit
Warning: This controller may be wired by a qualified person only. Adjustment made by a layman
may cause damage to system components.
The Room Unit shall be wired by a 2-core cable of max. 1.5 mm2 cross secion to a standard CIB bus,
to screw terminals on the PCB. The right polarity shall be uncionditionally respected.
Adjustments to the Room Unit (configuration and HW address) are then done via the controller's
web interface.
After the CIB bus is energized, the Room Unit is ready for operation. Its HW address is printed on a
label on the PCB.

R E G U L U S spol. s r.o.
Do Koutů 1897/3, 143 00 Praha 4
Tel.: +420 241 764 506
E-mail: info@regulus.cz
www.regulus.cz
4 / 21
Room Unit Simple Mode
Main value Actual room temperature measured by the temperature sensor located
inside the room unit.
Secondary value Desired room temperature – depends on the zone mode
(comfort/setback/holidays). The desired room temperature (corresponding
to the current zone mode) can be edited in steps of 0.1°C by UP (+0.1°C) and
DOWN (-0.1°C) keys.
Zone OFF and ON keys If a zone is switched on by the user, the ON key is displayed. By clicking the
ON key the zone will be switched off by the user and the OFF key is displayed.
By clicking the OFF key the zone will be switched on by the user and the ON
key will be displayed again.
Switching a zone ON/OFF by the user using Zone ON and Zone OFF keys is a function
that can be enabled or disabled on the service level of the controller’s web interface.
Weekday number Display of the actual weekday number.
Comfort/setback Display of the actual zone mode (comfort or setback).
Time program Displayed when the zone is in automatic mode and being heated following a
time program.
Holidays Displayed when the zone is in holiday mode.
comfort/setback
time program
holidays
main value
secondary value
UP and DOWN
keys
zone OFF and zone ON
keys
weekday number
source is heating
winter mode
active fault
FAULT DESCRIPT.
key

R E G U L U S spol. s r.o.
Do Koutů 1897/3, 143 00 Praha 4
Tel.: +420 241 764 506
E-mail: info@regulus.cz
www.regulus.cz
5 / 21
Heat source on The main source (depending on the controller version) is currently running.
Winter mode The zone is currently in the winter mode (no icon is shown in the summer
mode).
Active fault Indication of an active fault. The fault description could be displayed by
pressing the FAULT DESCRIPTION key.
Room Unit Display in Complete Mode
Main value Numeric display of the main value (usually temperature).
Secondary value Display of the secondary value – temperature, number, date, text. When the
text is too long and cannot fit into the 4-character display, it will run in an
endless loop.
Weekday number Display of the actual weekday number – only on initial displays and during
time program editing.
Temperature A thermometer symbol is displayed only when the main value shows the
temperature. A house symbol is displayed only when the outdoor
temperature is shown.
Comfort/setback Display of the actual zone mode (comfort or setback).
Time program Displayed when the zone is in automatic mode and being heated following a
time program.
Edit The icon flashes when the current value is being edited (edit mode).
weekday number
temp.
comfort/setback
time program
edit
holidays
source is heating
winter mode
active fault
main value
secondary value
scroll keys
(displays / value)
MENU key
CANCEL
key
OK
key
ventilator running

R E G U L U S spol. s r.o.
Do Koutů 1897/3, 143 00 Praha 4
Tel.: +420 241 764 506
E-mail: info@regulus.cz
www.regulus.cz
6 / 21
Holidays Displayed when the zone is in holiday mode.
Ventilator running The ventilation unit (depending on the controller version) is currently running
(along with the fan power indicator).
Source is heating The main source (depending on the controller version) is currently running.
Winter mode The zone is currently in the winter mode (no icon is shown in the summer
mode).
Active fault Indication of an active fault (on initial displays only). In the place of the
secondary value, the text of the last active fault runs in a loop.
Control keys
MENU key In the basic display (room temperature), this key will bring you to the main
menu. From all other displays it will bring you back to the basic display.
CANCEL key In the edit mode (edit icon flashing) this key will abort editing a value (no
changes will be saved).
It is used to return to the basic display (room temperature) from initial
displays. From all other displays it will bring you to a higher level.
OK key In the edit mode, it will save the value and finish editing.
By pressing OK, editing a value will be enabled, or enter into a selected menu
item confirmed.
Scroll keys They are used to scroll between displays within a group. If the edit mode is
active (the edit icon flashing), the value of a variable can be modified using
these two keys.
After 2 minutes of inactivity (no key pressed) automatic return to the basic display will follow (room
temperature displayed)..
Initial displays in Complete Mode
Initial displays are a group of displays of the highest level (pressing CANCEL keys does not bring you
to any higher group of displays) you can scroll between using the up and down arrows. The default
(basic) display in this group is the room temperature showing display (the value taken from the inner
temperature sensor of the room unit). By pressing MENU from this display, the main menu can be
opened and selected values edited.
Other displays may offer mode selection, show outdoor temperature or current DHW recirculation
and show some important system temperatures.
The basic display permits editing the desired room temperature (comfort/setback depending on the
current mode), while the current mode display permits selecting the zone mode

R E G U L U S spol. s r.o.
Do Koutů 1897/3, 143 00 Praha 4
Tel.: +420 241 764 506
E-mail: info@regulus.cz
www.regulus.cz
7 / 21
(auto/comfort/setback), and the recirculation display enables turning on DHW recirculation for a
preset period.
Entering the menu from the basic display and some displays within the initial group of
displays may be unavailable in some controller versions.
Basic display (room temperature)
Main value Actual room temperature – measured with a temperature sensor inside the
room unit.
Secondary value Information if the zone is switched on/off by a user (ON/OFF).
Comfort/Setback/Holidays Current zone mode, showing info on the desired temperature.
Time program Displayed when the zone is in automatic mode and being heated following a
time program.
Heat source on The main source (depending on the controller version) is currently running.
Winter mode The zone is currently in the winter mode.
MENU key Access to the main menu for editing selected parameters (may be
inaccessible, depending on the controller version).
OK key Editing the current desired room temperature.

R E G U L U S spol. s r.o.
Do Koutů 1897/3, 143 00 Praha 4
Tel.: +420 241 764 506
E-mail: info@regulus.cz
www.regulus.cz
8 / 21
The current desired room temperature is based on the zone mode. If the zone is running in the
comfort mode, the comfort room temperature can be edited; if the zone is running in the setback
mode, the setback room temperature can be edited.
Editing the desired temperature during the Holiday mode is possible from the respective menu only.
Editing the current desired temperature
Main value Editing the current desired room temperature (comfort/setback).
Comfort/Setback Zone mode is shown here, i.e. also the temperature being edited on the
display.
Mode selection display

R E G U L U S spol. s r.o.
Do Koutů 1897/3, 143 00 Praha 4
Tel.: +420 241 764 506
E-mail: info@regulus.cz
www.regulus.cz
9 / 21
Comfort/Setback Current zone mode.
Time program Automatic zone mode – comfort/setback controlled by the zone time
program.
OK key Entering the zone mode editing.
Editing zone mode
A zone mode can be changed using the up and down arrows. 3 modes are available – permanent
Comfort (Comfort icon displayed), permanent Setback (Setback icon displayed) and Automatic (time
program symbol displayed).
If the Automatic mode is selected, the desired room temperature is based on the zone time program
with automatic transitions between comfort and setback temperatures. Permanent Comfort/Setback
will override the time program, fixing the desired temperature at a Comfort/Setback value.
Outdoor temperature display
Main value Current outdoor temperature.
Secondary value Current time.

R E G U L U S spol. s r.o.
Do Koutů 1897/3, 143 00 Praha 4
Tel.: +420 241 764 506
E-mail: info@regulus.cz
www.regulus.cz
10 / 21
Immediate recirculation display
Secondary value CIRC text and the info on the immediate recirculation function on are
displayed alternately (ON/OFF).
OK key Entry into editing and switching on immediate recirculation.
Editing immediate recirculation
Main value Time period (in minutes) when the immediate recirculation function will be
on.
Secondary value CIRC and MIN texts are displayed alternately (recirculation time in minutes).
The immediate recirculation will be started on pressing the OK key and will be running for the preset
time. After that it will be switched off again and return to the preset automatic mode.
Table of contents
Other Regulus Thermostat manuals

Regulus
Regulus ST311 User manual

Regulus
Regulus TP08 User manual

Regulus
Regulus TP44 User manual

Regulus
Regulus BB1-1000 User manual

Regulus
Regulus TP44 RF User manual

Regulus
Regulus TP 07-01 User manual

Regulus
Regulus TP18 LCD User manual

Regulus
Regulus Caleon User manual

Regulus
Regulus TZ33 User manual

Regulus
Regulus TP34 User manual
Popular Thermostat manuals by other brands

Saswell
Saswell SAS920XWHB-7-S-RF User manual and warranty card

Aircalo
Aircalo TFP1-ET85P2 operating manual

Honeywell
Honeywell CM721 user manual

Carrier
Carrier DEBONAIR 33CS Installation and operating instructions

Lennox
Lennox iHarmony Zone Thermostat Installation and setup guide

Gemtech
Gemtech GT7000 Operation