Quell QM10 User manual

Smoke Alarm
Manual
Model QM10
Product code 138625
Photoelectric smoke alarms are designed to detect visible particles
(associated with slow smouldering fires). Home fires develop in
different ways and are often unpredictable. For maximum protection
against fast flaming fires and slow smouldering fires, both ionisation
and photoelectric alarms should be installed.
Copyright © 2020 carrier. All rights reserved.
2
Multi Purpose Photoelectric
Chubb Fire and Security Pty Ltd is part of the Carrier Global Corporation
(NYSE: CARR) group of companies.
Quell® is a registered trademark of Chubb Fire & Security Pty Ltd

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . 1
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . 2–8
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . 9–10
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . 12
Fire Safety . . . . . . . . . . . . . . . . . . . . . . . . . . 13-14
Good Safety Habits . . . . . . . . . . . . . . . . . . . 15
Warranty & Contact Details . . . . . . . . . . . . 16-17
Contents
Introduction
Model QM10
If you have any questions about the operation or installation of
your alarm, please call 1800 654435.
Figures 1A to 2B will help you determine the correct location
of safety products.
WARNING! Smoke alarm must be attached to mounting plate
to operate.
IMPORTANT! Read all instructions before installation and
keep this manual near the alarm for future reference.
1
Manufactured in China for:
Chubb Fire & Security Pty Ltd
Telephone : 1800 654 435
Website: www.quell.com.au
2
Troubleshooting . . . . . . . . . . . . . . . . . . . . 11-12
Product Specifications:
POWER:built-in DC3V(CR123A) Lithium battery(battery not
replaceable)
OPERATING CURRENT:<8uA(standby),<70mA(alarm)
ALARM VOLUME: >85dB(A)at 3 meters.
ALARM SENSITIVITY:0.115-0.181dB/m
SILENCE TIME: approx. 10 minutes
SMOKE ALARM DEVICE SOUND PATTERN:
ISO8201(BI 0.5s-pause 0.5s–BI 0.5s–pause 0.5s–BI 0.5s–
pause 1.5s, with the red LED flash, repeats pattern).
COMPLY WITH STANDARD:AS3786:2014
Building F Unit 1B
3-29 Birnie Ave
Lidcombe NSW, 2141 Australia

Installation Instructions
2
By law at least one smoke alarm must be installed on
each level of your home ( Figure 1B).
Recommended Locations
•In every room where someone sleeps with the door
closed. The closed door may prevent an alarm located
outside from waking the sleeper.
•In the immediate area of bedrooms and the exit path
from all sleeping areas (Figure 1A).
•In stairways, as stairways act like chimneys for smoke
and heat.
•In any room where large electrical appliances are
operated (e.g., portable heaters or humidifiers).
•If a hallway or room is more than 9.1m
long, place
at both ends.
•For maximum household protection see Figure 1C.
Things to Consider:
For Ceiling Mounting:
Smoke from a fire will rise to the ceiling and spread
horizontally. Mounting the smoke alarm in the centre of
the ceiling places it closest to all points in the room.
•When mounting an alarm on the ceiling, locate it at a
minimum of 50cm from the side wall (Figure 2A).
•For sloped, peaked or cathedral ceilings the alarm
should be placed between 500mm and 1000mm from
the highest point of the ceiling (Figure 2B).
•Smoke alarms in rooms with ceiling slopes greater than
1m in 8m horizontally, should be located on the high
side of the room (Figure 2B).
2
alarms
For Wall Mounting:
When mounting the alarm on the wall, use an interior
10cm and a maximum of 30.5cm below the ceiling
wall with the top edge of the alarm at a minimum of
(Figure 2A)
Refer to your local state and federal laws or contact your local
fire brigade to determine the minimum installation requirments.

3
Installation
DINING
ROOM
LIVING
ROOM
Smoke Alarms for Minimum Protection
Ionisation Type Smoke Alarm with Alarm
Silencer (Hush®) or Photoelectric Type
Smoke Alarms for Additional Protection
KITCHEN BEDROOM
BEDROOM
BEDROOM
LIVING
ROOM KITCHEN
BEDROOMBEDROOM HALL
BASEMENT
FIGURE 1A
FIGURE 1C
FIGURE 1B
SINGLE FLOOR PLAN MULTIPLE FLOOR PLAN
BEDROOM
FAMILY ROOM
WORKSHOPBASEMENT
KITCHEN
HALL
GARAGE
MASTER
BEDROOM
FIRE
EXTINGUISHERS
SMOKE
ALARMS
FIRE BLANKET
TOTAL HOME PROTECTION
2

4
Installation
Figure 2A
2
Figure 2B
NOT IN
THIS AREA
ANYWHERE IN THIS
AREA
NOT IN
THIS AREA
ANYWHERE IN THIS
AREA
PEAK CEILING
SLOPED CEILING
500mm
1000mm
1000mm
500mm
DEAD AIR
DEAD AIR
DO NOT INSTALL
DO NOT INSTALL

5
Installation
Do Not Install Smoke Alarm Devices In The Following Places:
1:Near appliances or areas where normal combustion
regularly occurs (kitchens, near furnaces, hot water
heaters).
2:In areas with high humidity, like bathrooms or areas
near dishwashers or washing machines. Install al least
3 meters away from these areas.
3:Near air returns or heating and cooling supply vents.
Install at least 0.9 meter away from these areas. The air
could blow smoke away from the detector.
4:In rooms where temperatures may fall below 5℃ or rise
above 40℃, or in humidity higher than 85%. These
conditions will reduce battery life or cause an alarm fault.
5:In extremely dusty, dirty, or insect–infested areas.
These areas may affect smoke alarms device operation.
N.B. - Smoke alarms are not to be used with detector
guards unless the combination (alarm and guard) has
been evaluated and found suitable for that purpose.
2
Suitable for installation in leisure
accommodation vehicles
This smoke alarm is suitable for use in mobile homes and
caravans. This smoke alarm is not intended for any
non-residential, commercial or industrial application, nor
for any other purpose than described.
6:Do not place in garage.

6
·Take off the bracket from the alarm body.
·Put the bracket on the installation position, mark
installation hole of the bracket with pencil.
·Drill a 5mm hole through the pencil marks and insert
the two plastic plug supplied.
·Attach the bracket to the plastic plugs and fix tightly
the screws into the plastic plugs.(Refer to Figure 3).
·Fit the alarm on the bracket and turn the alarm body
clockwise, until matching well on the bracket.
·Press the test button on the unit. The alarm sounds 3
beeps–1.5 seconds pause, repeats until button is
released, if no sound, it indicates a defective alarm, you
can refer to”Trouble shooting”for solution or return
to your retailer during warranty.
·If you have any questions on installation, contact
customer service on 1800654435.
WARNING:
To prevent injury, this unit must be securely attached to
the ceiling in accordance with the installation instructions.
Installation
2

7
Installation
Figure 3E
2

8
Operation
Testing
The alarm must be fully mounted on bracket. Test the unit
to ensure proper operation by pressing the test button,
this will sound the alarm if the electronic circuitry, bracket
is mounted, horn, and battery are working. If no alarm
sounds, there is a defective battery or other failure, you
can refer to“Trouble shooting”section for solution.
DO NOT use an open flame to test your alarm, you could
damage the alarm or ignite combustible materials and
start a fire.
CAUTION: Due to the loudness(85 decibels) of the alarm,
Always stand an arms-length away from the unit when
testing.
Test the alarm weekly to ensure proper operation. Erratic
or low sound coming from your alarm may indicate a
defective alarm, you can refer to “Trouble shooting”
section for solution.
NOTE: WEEKLY TESTING IS REQUIRED.
LED indicators
Red LED-Flashing once every 40 seconds: indicates that
the smoke alarm device is operating properly.
Red LED-Flashing: when the test button is pressed, or
when the smoke alarm device sense particles of
combustion and goes into alarm (constant pulsating
sound), the red LED will flash once per second. The flashing
LED and pulsating alarm will continue until the air is
cleared or release test button. Red LED-Alarm silencer
(Hush mode) indication: The redLED will flash once every
8 seconds, indicating the smoke alarm device is in the
alarm silence (Hush) mode.
Low battery indication-An intermittent “chirp” with
red LED flashes once every 40 seconds: indicates that the
smoke alarm device is low battery, you may press the test
button for pause alarm for 10 hours, but it will reset
automatically after10 hours.
Fault indication-The alarm chirp occurs every 40 seconds.
2

9
NOTE: When the units chirp once every 40 seconds, you can
press the test button temporarily for pausing this warning
tone for 10 hours,it can still normally detect smoke during
this period, it only removes nuisance warning tone. You can
refer to “Trouble shooting” for solution, if there are still
failures, you MUST replace it with a new alarm at once or contact
your retailer during warranty.
Alarm silence(silence mode)
The silent feature has the capability of temporarily
desensitising the alarm circuit for approximately 10 minutes.
The red LED will flash once every 8 seconds, it indicates the
smoke alarm device is running into the silence mode. Smoke
alarm devices are designed to minimize nuisance alarms.
Combustion particles from cooking may set off the alarm if
the alarm is located close to the cooking area. Large
quantities of combustible particles are generated from spills
or when grilling/ frying. Using the fan on a range hood that
vents to outside(non-recirculating type) will also help remove
these combustible particles from the kitchen.
The alarm silence (test button) is extremely useful in a
kitchen area or other areas prone to nuisance alarms.The
silence feature is to be used only when a known alarm
condition, such as smoke from cooking activates the alarm.
The smoke alarm device is desensitised by pushing the alarm
silence(silence mode) on the smoke alarm device cover, the
alarm will silence to indicate that the alarm is in a temporarily
desensitised condition.
The smoke alarm device will automatically reset after
approximately10 minutes, if after this period, particles of
combustion are still present, the alarm will sound again.
The alarm silencer (silence mode) can be used repeatedly.
CAUTION: Before using the alarm silence, identify
the source of the smoke and be certain a safe condition exists.
DANGER: If the alarm sounds, and it is not being tested,it
means the unit is sensing smoke,THE SOUND OF THE ALARM
REQUIRES YOUR IMMEDIATE ATTENTION AND ACTION.
Operation
2
This manual suits for next models
1
Table of contents
Other Quell Smoke Alarm manuals
Popular Smoke Alarm manuals by other brands

System Sensor
System Sensor DH500ACDC Installation and maintenance instructions

Resolution Products
Resolution Products RE612 CryptiX quick start guide

First Alert
First Alert PC900V user manual

Eminent
Eminent EM6590 E-Domotica user manual

Ei Electronics
Ei Electronics Ei Ei168RC user manual

Carrier
Carrier Kidde Quell Q301 user manual