CONTENTS
INTRODUCTION 1-1
Certifications and standards 1-1
Documentation package 1-2
Technical support 1-2
FUNCTIONS AND PARTS 2-1
Lock functions 2-1
Function descriptions 2-1
Lock parts 2-3
Exploded view of parts 2-3
Parts list 2-3
Trim parts 2-5
MAINTENANCE 3-1
Maintenance tools 3-1
Replacing levers 3-1
TROUBLESHOOTING 4-1
Troubleshooting hardware 4-1
Troubleshooting software 4-1
INSTALLATION MANUAL 5-1
Cylindrical installation instructions

iii
Proxess C-Series Service Manual
INTRODUCTION
The Proxess C-Series Service Manual contains important information to assist you in maintaining your C-Series
Lock.
CERTIFICATIONS AND STANDARDS
ANSI/BHMA A156.25 (Indoor/Outdoor)
ANSI/BHMA A156.2 Grade 1
UL 294
ULC S319 PDR
UL10C Positive Pressure Rated
UL10B Neutral Pressure Rated
FCC Part 15
ADA Compliant
RoHS
Industry Canada (IC)
ETSI EN 300 330-1
ETSI EN 301 489-1
ETSI EN 301 489-3
CENELEC EN 61000-6-3
IEC61000-4-2 ESD Immunity
CENELEC EN 50130-4
1-1

iv
Proxess C-Series Service Manual
DOCUMENTATION PACKAGE
Document Title Doc. No.
Cylindrical Installation Manual PXM1001
User Manual PXM1002
Software Manual PXM1003
TECHNICAL SUPPORT
•Your first source for technical answers is this C Series Service Manual.
•If you are not able to find an answer to your question in this manual, contact your local Proxess
Representative.
•If you do not know your local Proxess Representative, contact the Customer Service Department at
Proxess –303-317-6656.
1-2

v
Proxess C-Series Service Manual
FUNCTIONS AND PARTS LISTS
LOCK FUNCTIONS
FUNCTION DESCRIPTIONS
All locks are supplied in Construction Mode as a default and are meant to be reprogrammed at customer site
prior to installation.
CC –Construction Mode: Factory default setting. Upon first programming of the lock, the lock will switch to
Program Lock Function. A system ID (GUID) will be set by the factory allowing all credentials assigned to the
site system access until the lock is reprogrammed.
Inside lever is always unlocked for single action egress.
ST –Standard: Lock is normally in the locked state. Upon presentation of a valid credential, lock will
momentarily unlock to allow entry then revert to the normally locked state.
Inside lever is always unlocked for single action egress.
Inside
Outside
Latch
Shading indicates that
the lever is locked.
View looking down at
the top of the door
2-1

vi
Proxess C-Series Service Manual
XC –Emergency Classroom: (Presentation of a valid credential will unlock the lock for a user-selectable period
of time. This function will support unlock schedules and toggle to allow locking and unlocking when presented
with a valid credential. Furthermore, a BLE (Bluetooth) interface is supplied on the interior trim of the lock. The
BLE interface is paired with an active fob which enables a teacher or user to place a lock in lockdown state
from a distance up to 100 feet directly from the fob.
An emergency override credential allows designated administrators or emergency personnel access when
exterior lever is in locked position.
Inside lever is always unlocked for single action egress.
2-2

vii
Proxess C-Series Service Manual
PART AND PARTS LISTS
ST FUNCTION CHASSIS - STANDARD
Item Part No. Item Part.No
1PX10110001 12 PX10120005
2PX10110003 13 PX10110010
3PX10110004 14 PX10110011
4PX10110005 15 PX10110013
5PX10110006 16 PX10110014
6PX10110007 17 PX10120001
7PX10110002 18 PX10100002
8PX10110008 19 PX10100003
9PX10110016 20 PX10100004
10 PX10110012 21 PX10100001
11 PX10120002
2-3

viii
Proxess C-Series Service Manual
XC FUNCTION CHASSIS - EMERGENCY CLASSROOM
Item Part No. Item Part.No
1PX10110001 12 PX10120005
2PX10110003 13 PX10110010
3PX10110004 14 PX10110011
4PX10110005 15 PX10110013
5PX10110006 16 PX10110014
6PX10110007 17 PX10120001
7PX10110002 18 PX10100002
8PX10110008 19 PX10100003
9PX10110016 20 PX10100004
10 PX10110012 21 PX10100001
11 PX10120002 22 PX10110015
2-4

ix
Proxess C-Series Service Manual
TRIM PARTS
LATCH BACKSETS
Item Part. No. Description
B1 PX10120006 Standard 2 ¾"
B2 PX10120007 2 ⅜"
LATCHES
Optional latch extensions
B1
B2
2-5
2¾" (70mm) latch + 57mm extension tube for 5"
(127mm) requirement
2⅜" (60mm) latch + 35mm extension tube for 3¾"
(95mm) requirement
61.1
32.4
4.3

x
Proxess C-Series Service Manual
STRIKE PLATES
Item Part. No. Description
S1 PX10120002 Standard 2 ¾" strike
S2 PX10120003 ANSI 4 ⅞" strike
LEVERS
Item Part. No. Description
6 PX10120005A Angled Return; (most common lever)
7 PX10120005C Curved Return
9 PX10120005N Curved No Return; (no lever return)
6
8
9
2-6
S1
S2
This manual suits for next models
27