pro user INC150N User manual

1
P3
P16
P30
P34
P39
P44
P48
P52

2
Modified Sine Wave
1
1 2 3 4 5 1 8 7 6
2
5
4
3
2
1
6 7 9 8

3
Modified Sine Wave
Please read this instruction manual carefully before installing and starting up the
device, and store it in a safe place. If the device is passed on to another person, this
manual must also be handed over with it.
Contents
1. Notes on using the manual……………………………………………………………………4
2. Safety instructions………………………………………………………………………………4
3. Device guides……………………………………………………………………………………6
4. Technical description…………………………………………………………………………7
5. Connecting the inverter……………………… ………………………………………………8
6. Using the inverter…………… ………………………………………………………………10
7. Replacing the fuse……………………………………………………………………………12
8. Cleaning and caring for the inverter………………………………………………………12
9. Troubleshooting………………………………………………………………………………13
10.Guarantee………………………………………………………………………………………14
11.Disposal…………………………………………………………………………………………14
12.Technical date…………………………………………………………………………………15

4
Modified Sine Wave Noted on using the manual
1 Notes on using the manual
Caution
Safety instruction: Failure to observe this instruction can cause
material damage and impair the function of the device.
Caution
Safety instruction: relating to a danger from an electrical current or
voltage. Failure to observe this instruction can cause material damage and
personal injury and impair the function of the device.
Note
Supplementary information on operating the device
☞Action: This symbol indicates that action is required on your part. The required
action is described step-by-step.
√This symbol describes the result of an action.
Please observe the following safety instructions.
2 Safety instructions
2.1 Generalsafety
Caution
The manufacturer will not be held liable for claims for damage resulting from
the following:

5
ModifiedSineWave Safetyinstruction
―Faulty assembly or connection
―Damage to the appliance resulting from mechanical influences and excess voltage
―Alterations to the device without express permission from the manufacturer
―Use for purposes other than those described I the operating manual
―Use the device only as intended.
―Do not operate the device in a damp or wet environment.
―Maintenance and repair work may only be carried out by qualified personnel who are
familiar with the risk involved and the relevant regulations.
2.2 Safety when installing the device
● Ensure the device is standing firmly.
The device must be set up and fastened in such a way that it cannot tip over or fall down.
● Take the precautions necessary to ensure that children cannot interfere with operation.
Dangerous situations may occur which cannot be recognized by children!
● Do not expose the device to a heat source (such as direct sunlight or heating). Avoid
additional heating of the device in this way.
For installation on boats
● If electrical devices are incorrectly installed on boats, corrosion damage might occur.
Have the inverter installed by a specialist (marine) electrician.
Electrical cables
● If cables have to be fed through metal walls or other walls with sharp edges, use ducts or
wire bushings to prevent damage.
● Do not lay cables which are loose or bent next to electrically conductive material (metal).
● Do not pull on the cables.
● Do not lay the 230 V mains cable and the 12 V DC cable in the same duct.
● Fasten the cables securely.
● Lay the cables so that they cannot be tripped over or damaged.

6
ModifiedSineWave Safetyinstruction
2.3 Operating the appliance safely
Caution
Note the following basic safety information when using electrical devices to protect
against:
―Electric shock
―Fire hazards
―Injury
● Do not operate the advice near gas or flammable material; the surface temperature can
reach up to 65°C.
● Operate the device only if you are certain that the housing and the cables are
undamaged.
● Make sure the air inlets and outlets of the device are not covered.
● Ensure good ventilation.
● Do not connect the 230 V output of the inverter (fig. 1.2, page 2) to a different 230 V
source.
● Even after the fuse triggers, parts of the inverter remain live.
● Always disconnect the power supply when working on the device.
3 Device guides
Description Item No.
Modified sine wave INC150N: inverter in cup shape with USB socket and cable for 12V socket. INC150N
Modified sine wave INV150N: inverter with USB socket, and cable for 12V socket. INV150N
Modified sine wave INV300N: inverter with USB socket, and one cable for 12V socket, and two cables for 12V battery. INV300N
Modified sine wave INV600N: inverter with USB socket, and one cable for 12V socket, and two cables for 12V battery. INV600N
Modified sine wave INV1000N: inverter with USB socket, and two cables for 12V battery. INV1000N
Modified sine wave INV1500N: inverter with USB socket, and two cables for 12V battery. INV1500N
Modified sine wave INV2000N: inverter with USB socket and two cables for 12V battery. INV2000N

7
ModifiedSineWave Deviceguides
4 Technical description
The inverters are used to convert a direct current of 12V into a 230V AC supply of 50 HZ,
and/or 5V 2100mA USB.
The inverter can be operated wherever there is a 12V DC supply. The devices are
additionally cooled with a load fan.
The maximum constant output for the devices is as follows:
● For INC150N and INV150N inverters 150W
● For INV300N inverter 300W
● For INV600N inverter 600W
● For INV1000N inverter 1000W
● For INV1500N inverter 1500W
● For INV2000N inverter 2000W
Never connect devices that have a higher power requirement.
The inverter is equipped with protection against thermal and electrical over-loading, as well
as excess and insufficient voltage. The inverter alarms and switches off:
● if its internal temperature is too high
● if the load exceed the values stated above
● if the input voltage is too high or too low
The inverter can be switched on and off using the switch directly on the device.

8
ModifiedSineWave Technicaldescription
Note
Note when connecting devices with an electrical drive (such as power drills
and refrigerators), that they often require more power than the data is
indicated on the type plate.
5 Connecting the inverter
5.1 Fastening the inverter
You can fasten the inverters (INV300N, INV600N, INV100N0, INV1500N and INV2000N) by
screwing through the holes on the underside.
When selecting the installation location, observe the following instructions:
● The inverter can be mounted horizontally or vertically.
● The inverter must be installed in a place that is protected from moisture.
● The inverter may not be installed in the presence of flammable materials.
● The inverter may not be installed in a dusty environment.
● The place of installation must be well-ventilated. A ventilation system must be present for
installations in small, closed spaces. The minimum clearance around the inverter must
be at least 25 cm.
● The air intake on the front side or the air outlet on the back of the inverter must remain
clear.
● For ambient temperatures higher than 40°C (such as in engine or heating compartments,
or direct sunlight). The heat from the inverter under load can lead to the automatic
shut-off of the inverter.
● The installation surface must be level and sufficiently sturdy.
Caution
Before drilling any holes, ensure that no electrical cables or other parts of the
vehicle can be damaged by drilling, sawing and filing.

9
Modified Sine Wave Connecting the inverter
5.2 Connecting the inverter with car socket (INC150N, INV150N,
INV300N and INV600N)
The inverter is connected via a plug connected to a 12V socket. The middle pin of the plug
must be connected to the position wire and the two side brackets of the plug must be
connected to the negative wire.
Caution
Make sure the plug is firmly connected in the socket. If the connection is loose,
the plug may heat up.
Caution
The rating of the socket, the supply cable and the fuse must be at most 15amps. Do not
put in a fuse with a higher rating.
Caution
Always check the rated power of device before connecting with car socket. Its rated
power can NOT be more than 100W.
5.3 Connecting the inverter with battery (INV300N, INV600N,
INV1000N, INV1500N and INV2000N)
To set up the inverter, connect the red cable to the positive pole (+) of the battery and
inverter, connect the black cable to the negative pole (-) of the battery and inverter.
Caution
Make sure the battery poles are clean when connecting the terminals.
Tighten the nuts and bolts to a torque of 12-13 Nm. Loose connections may cause
overheating.

10
Modified Sine Wave Connecting the inverter
Caution
Do not reverse the polarity. Reversing the polarity of the connections will
cause a great spark and the internal fuses will melt.
Caution
Only extend the connection line with cables with and equal or greater cross
section.
Below cross section is for 100% copper wire, does not include thickness of
wire cover.
Device Required cable cross section Cable standard in AWG
100% copper wire (American wire gauge)
INV300N 3.00mm² 14#AWG
INV600N 5.30mm² 10#AWG
INV1000N 10.00mm² 8#AWG
INV1500N 16.00mm² 5#AWG
INV2000N 2x12.00mm² 2x7#AWG
6 Using the inverter
Switch on at the device
☞Set the main switch(fig. 1.4 page 2 ) to “ON”.
√The green LED (fig. 1.5 page 2) lights up.
Switch off at the device
☞Set the main switch(fig. 1.4 page 2 ) to “OFF”.
√The green LED (fig. 1.5 page 2) goes out.
This manual suits for next models
6
Table of contents