Premium PBCC1725XS User manual


Horizontal Bottle Coolers
1
INSTALLATION / OPERATION
IMPORTANT! PLEASE READ BEFORE INSTALLATION
■ If the unit has recently been transported, please let unit stand still for a
minimum of 24 hours before plugging it in.
■ Make sure that the unit drops down to the desired temperature before
loading the unit with product.
■ Make sure that there is proper ventilation around the unit in the area where
it will operate.
■ Make sure all accessories are installed (i.e. shelves, shelf clips, casters)
before plugging the unit in.
■ Please read through the Operation / Owner’s Manual in its entirety before
installation.
CABINET LOCATION GUIDELINES
■ Install the unit on strong and leveled surfaces.
·Unit may make noises if the surface is uneven.
·Unit may malfunction if the surface is uneven.
■ Install the unit in an indoor, well-ventilated area.
·Unit performs more efficiently in a well-ventilated area.
·For best performance, please maintain clearance of 4” on the back of
the unit.
·Outdoor use may cause decreased efficiency and damage to the unit.
■ Avoid installation in a high humidity and/or dusty area.
·Humidity could cause unit to rust and decrease efficiency of the unit.
·Dust collected on condenser coil will cause unit to malfunction. Clean
the condenser at least once a month with a brush or a clean cloth.

Horizontal Bottle Coolers
2
■ Select a location away from heat and moisture-generating equipment.
·High environmental temperature will cause the compressor to
overwork, leading to higher electrical bills and gradual breakdown of
the unit.
ELECTRICAL
Please ensure that the required voltage of the compressor is being supplied at all
times. Low or high voltage can detrimentally affect the refrigeration unit.
All units should be plugged into a grounded and properly-sized electrical outlet
with appropriate surge protection. Please refer to the electrical requirements on
the nameplate. Please make sure that your unit has its own dedicated outlet. Do
not use an extension cord.
TEMPERATURE CONTROLS
The temperature controls are factory-set to maintain an average temperature of
38oF in refrigeration. To maintain a different temperature, simply adjust the control
knob located inside the unit.
To decrease the temperature (colder), turn clockwise. To increase the
temperature (warmer), turn counter-clockwise –see diagram.
LOADING PRODUCT
The bin dividers have been installed at the factory for your convenience. Feel free
to reposition the dividers as you see fit. To remove the bin dividers, simply push
the divider towards the back wall until the front of the divider is removed from the
positioning holes. To install, position the divider to the desired holes, making sure
that the pressure spring is installed properly.

Horizontal Bottle Coolers
3
PAY CLOSE ATTENTION TO THE LOAD LIMIT STICKERS
LOCATED ON THE INTERIOR WALLS OF THE UNIT. DO NOT
LOAD PRODUCT ABOVE THE LOAD LIMIT STICKERS OR
ABOVE THE TOP CROSS BAR OF THE BIN DIVIDERS. LOADING
PRODUCT ABOVE THE LOAD LIMIT STICKERS WILL HARM THE
PERFORMANCE OF THE UNIT.
CAUTION
Setting the temperature control to the coldest setting may cause the evaporator
coil to freeze and ice up. This will eventually result in a warmer cabinet
temperature.
Temperature range from
7 (coldest) to 1 (warmest).

Horizontal Bottle Coolers
4
Do not load
product above
the top crossbar.
Doing so will
harm the
refrigerator.
SAFETY / WARNING
Please pay close attention to the safety notices in this section.
Disregarding these notices may lead to serious injury and/or damage to the
unit.
ATTENTION
■ To minimize shock and fire hazards, be sure not to overload outlet. Please
designate one outlet for your unit.
■ Do not use extension cords.
■ Do not put your hands under the unit when the unit is required to be moved.
■ When the unit is not in use for a long period o time, please unplug the unit from
the outlet.
■ After unplugging the unit, wait at least 10 minutes before re-plugging it.
Failure to do so could cause damage to the compressor.

Horizontal Bottle Coolers
5
UNPLUG CORD
■ To minimize shock and fire hazards, please do not plug or unplug the cord with
wet hands.
■ During maintenance and cleaning, please unplug the unit.
PROPER GROUDING REQUIRED
■ To minimize shock and fire hazards, make sure that the unit is properly
grounded.
WARNING
■ Do not attempt to remove or repair any component unless instructed by
factory.
■ Make sure that the unit is not resting on or against the electrical cord or plug.
■ To minimize personal injury, do not hang on the doors.
■ Do not store any flammable or explosive gas or liquids inside the unit.
■ Do not attempt to alter or tamper with the electrical cord.
■ Do not set the desired temperature out of the recommended temperature
range: (32oF- 50oF).
SAVE THESE INSTRUCTIONS

Horizontal Bottle Coolers
6
REGULAR MAINTENANCE
CLEANING THE CONDENSER COIL
■ For efficient operation, it is important that the condenser surface is kept free of
dust, dirt, and lint.
■ We recommend cleaning the condenser coil and fins at least once per month.
■ Clean with a commercial condenser coil cleaner, available from any kitchen
equipment retailer. Brush the condenser fins from top to bottom, not side to
side.
■ After cleaning, straighten any bent condenser fins with a fine comb.
CLEANING THE FAN BLADE AND MOTOR
■ If necessary, clean the fan blades and motor with a soft cloth. If it is necessary
to wash the fan blades, cover the fan motor to prevent moisture damage.
CLEANING THE INTERIOR OF THE UNIT
■ When cleaning the cabinet interior, use a solution of warm water and mild
soap.
■ Do not use steel wool, caustic soap, abrasive cleaners, or bleach that may
damage the stainless steel surface.
■ Wash door gaskets on a regular basis, preferably weekly. Simply remove the
door gasket from the frame of the door, soak in warm water and soap for thirty
(30) minutes, dry with a soft cloth, and replace.
■ Check door gaskets for proper seal after they are replaced.
■ Periodically remove the shelves and pilasters from the unit and clean them
with mild soap and warm water. To remove the pilasters, first remove the

Horizontal Bottle Coolers
7
shelves and shelf brackets. Then, simply lift the pilaster up and out.
WARNING
Disconnect power cord before cleaning any parts of the unit.
TROUBLE SHOOTING
Before requesting any service on your unit, please check the following points.
Please note that this guide serves only as a reference for solutions to common
problems.
SYMPTOM POSSIBLE CAUSE CORRECTIVE ACTION
Compressor
not running. Fuse blown or circuit bre
aker tripped.
Power cord unplugged.
Thermostat set too high.
Cabinet in defrost cycle.
Replace fuse or reset circuit
breaker.
Plug in power cord.
Set thermostat to a lower
temperature.
Wait for defrost cycle to finish.
Condensing
unit runs for
long periods
of time.
Excessive amount of warm product
placed in cabinet.
Prolonged door opening or door ajar.
Door gasket(s) not sealing properly.
Dirty condenser coil.
Evaporator coil iced over.
Allow adequate time for product
to cool down.
Ensure doors are closed when
not in use. Avoid opening doors
for long periods of time.
Ensure gaskets are snapped in
completely. Remove gasket
and wash with soap and water.
Check condition of gasket and
replace if necessary.
Clean the condenser coil.
Unplug unit and allow coil to
defrost. Make sure thermostat

Horizontal Bottle Coolers
8
is not set too cold. Ensure that
door gasket(s) are sealing
properly.
Cabinet
temperature
is too warm.
Thermostat set too warm.
Blocking air flow.
Excessive amount of warm product
placed in cabinet.
Fuse blown or circuit breaker tripped.
Dirty condenser coil.
Prolonged door opening or door ajar.
Evaporator coil iced over.
Set thermostat to a lower
temperature.
Re-arrange product to allow for
proper air flow. Make sure there
is at least four inches of
clearance from evaporator.
Allow adequate time for product
to cool down.
Replace fuse or reset circuit
breaker.
Clean the condenser coil.
Ensure doors are closed when
not in use. Avoid opening doors
for long periods of time.
(see above)
Cabinet is
noisy. Loose part(s).
Tubing vibration.
Locate and tighten loose
part(s).
Ensure tubing is free from
contact with other tubing or
components.

Horizontal Bottle Coolers
9
INSTALACION / OPERACION
IMPORTANTE! FAVOR LEER ANTES DE LA INSTALACION
■ Si la unidad ha sido transportada recientemente, por favor, permita que la
unidad este inmóvil por un mínimo de 24 horas antes de conectarla.
■ Asegúrese de que la unidad llegue a la temperatura deseada antes de
cargar la unidad con el producto.
■ Asegúrese de que existe una ventilación adecuada alrededor de la unidad
en la zona donde operará.
■ Asegúrese de que todos los accesorios están instalados (por ejemplo,
estantes, abrazaderas de repisas, ruedas) antes de enchufar la unidad.
■ Por favor, lea el Manual de Operación / Manual del Propietario en su
totalidad antes de la instalación.
GUIA PARA LA UBICACION DEL GABINETE
■ Instale la unidad sobre una superficie fuerte y nivelada.
·La unidad puede hacer ruidos si la superficie es irregular.
·La unidad puede funcionar incorrectamente si la superficie es
irregular.
■ Instale la unidad en una zona cubierta y bien ventilada.
·La unidad trabaja más eficientemente en un área bien ventilada.
·Para un mejor rendimiento, mantenga una distancia de 4" en la parte
posterior de la unidad.
·El uso al aire libre puede causar daño y disminución de la eficiencia a
la unidad.
■ Evite la instalación en una zona de humedad alta o polvorienta.
·La humedad puede causar oxido o moho a la unidad y reducirá la
Table of contents
Languages: