Planet IFT-802 User manual

Industrial 10/100Base-TX to
100Base-FX Media Converter
IFT-802
User's Manual

Trademarks
Copyright © PLANET Technology Corp. 2006.
Contents subject to which revision without prior notice.
PLANET is a registered trademark of PLANET Technology Corp. All other trademarks belong to their
respective owners.
Disclaimer
PLANET Technology does not warrant that the hardware will work properly in all environments and
applications, and makes no warranty and representation, either implied or expressed, with respect to the
quality, performance, merchantability, or fitness for a particular purpose.
PLANET has made every effort to ensure that this User's Manual is accurate; PLANET disclaims liability
for any inaccuracies or omissions that may have occurred.
Information in this User's Manual is subject to change without notice and does not represent a
commitment on the part of PLANET. PLANET assumes no responsibility for any inaccuracies that may be
contained in this User's Manual. PLANET makes no commitment to update or keep current the
information in this User's Manual, and reserves the right to make improvements to this User's Manual
and/or to the products described in this User's Manual, at any time without notice.
If you find information in this manual that is incorrect, misleading, or incomplete, we would appreciate
your comments and suggestions.
FCC Warning
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant
to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
Instruction manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in which case the user will be
required to correct the interference at whose own expense.
CE Mark Warning
This is a Class A product. In a domestic environment, this product may cause radio
interference, in which case the user may be required to take adequate measures.
WEEE Warning
To avoid the potential effects on the environment and human health as a result of the
presence of hazardous substances in electrical and electronic equipment, end users of electrical and
electronic equipment should understand the meaning of the crossed-out wheeled bin symbol. Do not
dispose of WEEE as unsorted municipal waste and have to collect such WEEE separately.
Revision
PLANET Industrial Fast Ethernet Media Converter User's Manual
For model: IFT-802
Revision: 1.0(February.2006)
Part No. EM_IFT802(2081-AH0010-000)

Table of Contents
1. INTRODUCTION................................................................................................................... 4
1.1 Packet Contents.............................................................................................................. 4
1.2 How to Use This Manual ................................................................................................. 4
1.3 Product Feature............................................................................................................... 4
1.4 Product Specification....................................................................................................... 5
2. INSTALLATION..................................................................................................................... 7
2.1 Product Description......................................................................................................... 7
2.2 Mounting Installation ......................................................................................................11
3. Hardware Installation ........................................................................................................ 14
4. TROUBLESHOOTING........................................................................................................ 16
4.1 Incorrect connections .................................................................................................... 16
4.2 Diagnosing LED Indicators............................................................................................ 16
Appendix A Networking Connection ................................................................................... 18
A.1 Switch‘s RJ-45 Pin Assignments .................................................................................. 18
A.2 RJ-45 cable pin assignment ......................................................................................... 18

1. INTRODUCTION
1.1 Packet Contents
Check the contents of your package for following parts:
▫Industrial Media Converter x1
▫DIN-Rail kit (screwed on the switch)
▫Wall-mount kit (wall-mount plate with 6 screws)
▫CD-ROM user's manual x1
If any of these are missing or damaged, please contact your dealer immediately, if possible, retain the
carton including the original packing material, and use them against to repack the product in case there is
a need to return it to us for repair.
1.2 How to Use This Manual
This User Manual is structured as follows:
Chapter 2, HARDWARE NSTALLATION
The chapter explains the functions of the Converter and how to physically install the Converter.
Chapter 3, NETWORK INSTALLATION
The chapter explains how to install the Converter in the network.
Chapter 4, TROUBLE SHOOTING
The chapter explains how to trouble shooting of the Converter.
Chapter 5, APPENDIX A Networking Connection
The chapter contains cable information of the Converter.
1.3 Product Feature
Hardware Feature:
▫UTP to Fiber Media Converter
▫Auto Negotiation Speed and Half / Full Duplex
▫Support 12 to 48VDC power inputs
▫TX port support Auto MDI/MDI-X
▫Relay alarm output for port link failure
▫IEEE 802.3x flow control support
▫Flow control on full-duplex
▫Back pressure on half-duplex
▫Built-in Link Lose Forwarding Technology

▫DIN-Rail or wall mountable
▫DIP-switches to set the operation mode and Link- Lost-Forwarding function.
Industrial Conformance:
▫12~48V DC, redundant power with polarity reverse protect function and connective
removable terminal block for master and slave power
▫0 to 60 Degree C operation temperature
▫IP-30 Aluminum case
▫EMI complies with FCC Class A, CE EN6100-4-2, CE EN6100-4-3, CE EN6100-4-4, CE
EN6100-4-5 and CE EN6100-4-6
▫Stability testing with IEC60068-2-32(Free fall), IEC60068-2-27(Shock) and
IEC60068-2-6(Vibration)
1.4 Product Specification
Model IFT-802
Standard IEEE 802.3 10BASE-T
IEEE 802.3u 100BASE-TX / 100BASE-FX
IEEE 802.3x Flow Control and Back pressure
10/100Mbps TP CAT-3/5 (10/100Mbps) Twisted Pair cable Auto MDI/MDI-X and Auto-Negotiation
Function Support
Fiber Connector Multi-Mode SC connector
Architecture Store and forward
Fiber Parameters Fiber Core: Multi-Mode (62.5/125µm, 50/125µm). Wavelength: 1310nm
Fiber Distance: Multi-Mode Fiber, up to 2Km
Link Lost Forward TX to Fiber: If TX port link down, the media converter will force Fiber port to link down
Fiber to TX: If Fiber port link down, the media converter will force TX port to link down.
DIP Switch DIP Switch 1:
ON: Enables Port Alarm
OFF: Disables Port Alarm
DIP Switch 2:
ON: Enables LLF (Link Lose Forwarding)
OFF: Disables LLF (Link Lose Forwarding)
DIP Switch 3:
ON: 100Base-FX Half-mode
OFF: 100Base-FX Full-mode
DIP Switch 4:
ON: 100Base-TX Full-duplex mode
OFF: Auto-Negotiation
LED Power (Green), Power1 (Green), Power2 (Green), Fault (Orange)
Fiber: Link/Activity (Green)
Half/Full Duplex (Orange)

TX: 10/100(Green)
Link (Green)
Half/Full Duplex (Orange)
Power Supply 12~48 VDC, Redundant power with polarity reverse and overlap current protection
function
Power Consumption 4.6 Watts
Installation Provide DIN rail kit and wall mount plate for 3-way installation
Operating environment 0~60 Degree C, 5%~90%RH (Non-condensing)
Storage environment -40~85 Degree C, 5%~90%RH (Non-condensing)
Dimension (W x D x H) 54 × 105 × 155 mm
Emission FCC Class A, CE mark
Stability testing IEC60068-2-32(Free fall), IEC60068-2-27(Shock), IEC60068-2-6(Vibration)

2. INSTALLATION
This section describes the functionalities of the Converter’s components and guides how to install it on
the rack or mount to the wall. Basic knowledge of networking is assumed. Please read this chapter
completely before continuing.
2.1 Product Description
2.1.1 Product Overview
The PLANET IFT-802 industrial 10/100BaseTX to 100BaseFX Media Converter is a cost- effective
solution for the converting 10/100Base-TX (Auto MDI/MDIX) to 100Base-FX cabling. It provides two
power inputs that can be connected simultaneously to the DC power sources. If one power input fails, the
other one acts as a backup.
The PLANET IFT-802 also provides relay alarm outputs to warn when the port link failure, so the
technician can respond quickly with appropriate emergency operation procedures. Also, there are DIP-
switches to set the operation mode for relay alarm, Fiber ports, link loss forwarding function, and UTP
operation mode.
2.1.2 Switch Front Panel
Figure 2-1 shows the front panel of the converter.
Figure 2-1 IFT-802 Front Panel

2.1.3 LED Indications
There are 9 diagnostic LEDs located on the Front panel of industrial media converter. They provide
real-time information of system and optional status. The following table provides description of the LED
status and their meanings for the industrial media converter.
LED Status Meaning
Green When the IFT-802 has power input s the LED will light on
Power
Off No any power inputs
Green Power on
Power 1
Off No power inputs
Green Power on
Power 2
Off No power inputs
Orange Power failure or UTP port failure or Fiber port failure
Fault
Off
No Power failure or UTP port failure or Fiber port failure occurs or the
port alarm disable
Green The port is linking with its link partner.
Blinks The port is transmitting or receiving packets from the FX device.
LNK/ACT(Fiber)
Off No device attached
Orange The port is operating in full-duplex mode.
FDX (Fiber)
Off Half-duplex mode or no device attached
Green In 100Mbps transmitting speed
10/100(UTP)
Off In 10Mbps transmitting speed
Green The port is linking with its link partner.
Blinks The unit is transmitting or receiving packets from the devices.
LNK/ACT(UTP)
Off No device attached
Orange The port is operating in full-duplex mode.
FDX (UTP)
Off Half-duplex mode or no device attached

2.1.4 DIP-Switch
The DIP-switch is used to configure operation mode for LLF (Link Lost Forwarding) operation mode for
UTP/Fiber port and relay alarm operation mode. The factory default mode of DIP switch is OFF.
DIP Switch No Status Description
ON Enable Port Alarm. If the port’s link fails, the fault LED will light up.
1 OFF Disable Port Alarm
ON LLF Enable
2 OFF LLF Disable
ON 100Base-FX Half Duplex mode
3 OFF 100Base-FX Full Duplex mode
ON 100Base-TX Full Duplex mode
4 OFF UTP Auto-Negotiation
Link Lose Forwarding:
When LLF is enabling, allow UTP link failures to be reported to the fiber side and also allow Fiber link
failure to be reported to the UTP side. Therefore, a link lost forward feature is provided in both UTP and
Fiber side.
#Notice:
Please don't change the DIP-switch setting when UTP or fiber port is transmitting or receiving data. It
may cause some data error. After change the DIP-switch setting, must execute Power OFF/ON to enable
new configures.
2.1.5 Converter Bottom Panel
The bottom panel of the Converter consist one terminal block connector within two DC power inputs and
one DC IN power jack for extra AC/DC power adapter. Figure 2-2 shows the bottom panel of the switch.
Figure 2-2 IFT-802 Bottom Panel.

2.1.6 Wiring the Power Inputs
Please follow below steps to insert the power wire.
V- V+ V- V+
1. Insert the positive and negative wires into the V+ and V- connector on the terminal block connector.
2. To tighten the wire-clamp screws for preventing the DC wires to loose.
2.1.7 Wiring the Fault Alarm Contact
The fault alarm contact is in the middle of terminal block connector as below figure shows. By inserting
the wires and set the DIPswitch at "ON" status, it will detect when power is failure or port link failure and
form an open circuit. And, the following figure shows an application example for the fault alarm contact.
Inset the wires into the falult alarm contact
Power Notice:
The wire range of terminal block is from 12~ 24 AWG.
Table of contents
Other Planet Media Converter manuals

Planet
Planet GST-802 User manual

Planet
Planet VC-101M User manual

Planet
Planet GT-915A User manual

Planet
Planet ICS-100 User manual

Planet
Planet IECC-210T User manual

Planet
Planet FT-807 User manual

Planet
Planet IGT-805AT User manual

Planet
Planet FT-90X FT-902S15 User manual

Planet
Planet ICS-100 User manual

Planet
Planet VC-201A User manual

Planet
Planet WGT-702 User manual

Planet
Planet FT-801 User manual

Planet
Planet FT-902 User manual

Planet
Planet VC-202 User manual

Planet
Planet FT-801 User manual

Planet
Planet GT-1205A User manual

Planet
Planet IGT-900 Series User manual

Planet
Planet ET-508 User manual

Planet
Planet WFT-801 User manual

Planet
Planet FST-801 User manual




















