PIKA Harbor Plus SB15p User manual

M00017-02
Operations Manual
Pika Harbor Smart Battery
Harbor Flex / Harbor Plus
Part of the Pika Energy Island™

Harbor Smart Battery
Serial Number:
RCP Number:

1Harbor Smart Battery Operation Manual M00017-02
We are committed to quality and constant improvement. All specications and descriptions
contained in this document are veried to be accurate at the time of printing. However, we reserve
the right to make modications at any time that may result in a change of specication without
notice in our pursuit of quality. If you nd any inconsistencies or errors in this document, please
Check the resources tab at www.pika-energy.com for the latest specications and manuals.
© 11/21/17 Pika Energy, Inc. All rights reserved.
All information in this document is subject to copyright and other intellectual property rights of
Pika Energy, Inc. This material may not be modied, reproduced or copied, in whole or in part,
without the prior written permission of Pika Energy, Inc. and its licensors. Additional information
is available upon request.

2 Harbor Smart Battery Operation Manual M00017-02
Table of Contents
Section 1: Introduction 4
About this manual 4
Symbols used in this Manual 4
About the Harbor Smart Battery 5
Battery Modules 6
Section 2: Safety instructions 7
General Warnings 7
Safety Shutdown 8
Battery Modules 8
Section 3: Operation and Controls 10
Communication 10
System Operational Modes 10
Battery State of Charge (SOC) Setpoints 11
User Interface 13
Section 4: Powering the Nanogrid Without Utility Power 15
Islanding 15
Power Search 15
Blackstart 16
Service and Maintenance Instructions 18
Annual Inspection and Maintenance 18
Service 19
End of Life 19
Section 6: Technical Reference 20
Section 7: Product Specications 21
Section 13: Notes 22

3Harbor Smart Battery Operation Manual M00017-02
Table of Contents

4 Harbor Smart Battery Operation Manual M00017-02
About this manual
Section 1: Introduction
About this manual
This Operation Manual provides instructions for the use, operation, and maintenance of the Pika
Harbor Series of smart batteries for simple, reliable energy storage with optional solar charging.
The Harbor Smart Battery is designed to house compatible lithium ion battery modules, and
connects directly to the Pika Islanding Inverter™ and other REbus™- compatible components of
the Pika Energy Island™ system from Pika Energy.
This Operation Manual includes full details on the use, operation, and maintenance of Harbor.
The companion document to this Operation Manual is the Harbor Installation Manual.
Please reference the Installation Manual for complete information on installing, wiring, and
commissioning the Harbor smart battery.
Symbols used in this Manual
WARNING: This indicates a fact or feature very important for the safety
of the user to prevent injury or death and/or which can cause serious
hardware damage if not applied appropriately.
CAUTION: Presents information to prevent damage to this product
EARTH GROUND SYMBOL

5Harbor Smart Battery Operation Manual M00017-02
Section 1: Introduction
About the Harbor Smart Battery
The Harbor Smart Battery is an easy-to-install energy storage device for efcient DC-coupled
performance. As a storage component of the Pika Energy Island, Harbor Smart Battery models
can be used for grid-connected solar applications such as self-supply, rate arbitrage and clean
backup power. Both the Harbor Flex™ and Harbor Plus™ models are designed to work seamlessly
with Pika Energy’s S2500 Series PV Link optimizers, and X7600 and X11400 Series Islanding
Inverters to form the Pika Energy Island system for grid-tie solar-plus-storage.
All Pika Energy products use the REbus™ 380VDC nanogrid to connect energy sources, storage,
loads and the grid. The REbus nanogrid automates the ow of power to enable plug-and-play
setup and operation of Pika Energy equipment. For more information about REbus, visit pika-
energy.com.
In the diagram below, a REbus compatible Pika Islanding Inverter is directly connected to PV Link
optimizers and high voltage energy storage on the DC (REbus) line, shown to the the left of the
inverter. To the right of the inverter are AC lines: 240VAC or 208VAC for grid and home loads, and
critical load support up to 50A.
Grid LoadsInverterBatterySolar
Fig 1. Example Energy Island

6 Harbor Smart Battery Operation Manual M00017-02
Battery Modules
Battery Modules
Harbor is designed to be used with Panasonic DCB-105 lithium ion battery modules. Do not
attempt to connect batteries of any other make or model to your Harbor Smart Battery, including
any other lithium ion battery, or any other type of battery.
WARNING: Use ONLY Panasonic DCB-105 lithium ion battery modules. DO
NOT CONNECT ANY OTHER BATTERY MODULES. DOING SO WILL VOID
THE WARRANTY AND MAY DAMAGE THE HARBOR SMART BATTERY.
Refer to the manufacturer’s documentation for information on the correct handling, storage, and
use of your battery modules.

7Harbor Smart Battery Operation Manual M00017-02
Section 2: Safety instructions
Section 2: Safety instructions
IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS!
General Warnings
SHOCK RISK: HIGH VOLTAGE ELECTRICITY
WARNING: To reduce the risk of injury, read all instructions and caution
markings before installing Harbor. Consult installation documentation for
all other REbus devices on the system.
WARNING: Harbor must be installed by trained and qualied technicians,
and in accordance with all instructions.
WARNING: Electrical installation in the United States shall be done in
accordance with all local electrical codes and/or the National Electrical
Code (NEC), ANSI/NFPA 70.
WARNING: Electrical installation in Canada shall be done in accordance
with all local electrical codes and/or the Canadian Electrical Code.
WARNING: Connecting the Pika Energy Island to the electric utility
grid must only be done after receiving prior approval from the utility
company and installation completed only by qualied personnel/licensed
electrician(s).
WARNING: This equipment is NOT intended for use with life support
equipment or other medical equipment or devices.
WARNING: Protection against lightning surges in accordance with local
electric codes are the responsibility of the installer.
WARNING: Connect only to REbus-compatible devices. Never connect to
any other power source, including raw PV output, AC power, or any non-
REbus compatible battery.
WARNING: TURN BATTERY DISCONNECT TO “OFF” TO PREVENT
TERMINALS FROM ENERGIZING.

8 Harbor Smart Battery Operation Manual M00017-02
Safety Shutdown
Safety Shutdown
The Pika Energy Island system can signal to connected devices on REbus to shut down and limit
output voltage to a safe level. The red Safety Shutdown button on the front of Pika Islanding
Inverter activates a Safety Shutdown. An external shutdown button may also be installed, given
appropriate labeling. See the section titled “External Safety Shutdown Switch” in the Islanding
Inverter Installation manual.
To enter a Safety Shutdown, press and hold the red button on the front of the inverter. The
Safety Shutdown LED will illuminate and the LCD screen will indicate a Safety Shutdown has
been initiated.
In a system congured to provide backup power, the DC bus will remain energized on loss of AC
grid power. Upon entering a Safety Shutdown, a shutdown signal will be transmitted to all devices
connected to REbus. In Safety Shutdown, the Islanding Inverter will disconnect from the grid,
stop sourcing power to REbus, and immediately disable all sources on REbus by sending a global
shutdown signal. All PV Link optimizers will disconnect their output. The Safety Shutdown LED
will be illuminated to show that the inverter has entered a Safety Shutdown. DC bus voltage will
be displayed on the inverter screen.
WARNING: BEFORE PERFORMING SERVICE, ALWAYS INITIATE A SYSTEM-
WIDE SAFETY SHUTDOWN AND TURN THE FRONT PANEL BATTERY
DISCONNECT SWITCH TO “OFF” ON ALL CONNECTED SMART BATTERIES.
UNLESS THE BATTERY SWITCH IS “OFF”, THE BATTERY MAY PERFORM
A POWER SEARCH AT ANY TIME WHICH WILL CREATE DANGEROUS
VOLTAGE AT THE REBUS TERMINALS.
Battery Modules
Refer to the battery manufacturer’s documentation for warnings, hazards, and safe handling
instructions for your battery modules.
This manual suits for next models
1
Table of contents
Popular Camera Accessories manuals by other brands

Viltrox
Viltrox EF-NEX Mount instructions

Calumet
Calumet 7100 Series CK7114 operating instructions

Ropox
Ropox 4Single Series User manual and installation instructions

Cambo
Cambo Wide DS Digital Series Main operating instructions

Samsung
Samsung SHG-120 Specification sheet

Ryobi
Ryobi BPL-1820 Owner's operating manual











