Once BioShift 24-0230 User manual

BioShift Pass-Through UV-C Germicidal
Chamber - Instruction Manual
This manual provides user guidelines and additional operation
instructions for the A1 BioShift Pass-Through UV-C Germicidal Chamber.
(Model 24-0230)
For service or parts call your
sales representative, visit our website:
www.once.lighting/uv-c
Or contact us at:
Once Inc.
United States
15255 23rd Ave N
Plymouth, MN 55447
+1 (763) 381-5621
Germany
Am Südfeld 7
49377 Vechta
+49 (0) 4441 8898-10
Poland
Wloclawska 167
87-100 Tourn
+48 (56) 699-5330

TABLE OF CONTENTS
Introduction ................................................................................................................................................ 2
Specications .............................................................................................................................................. 3
Safety ......................................................................................................................................................... 4-5
Installation ................................................................................................................................................... 6
Touchscreen Display ............................................................................................................................ 7-9
Home Screen Components ................................................................................................ 7
Maintenance Screen Components .................................................................................. 8
Settings Screen Components ............................................................................................ 9
Programming ............................................................................................................................................10
Cycle Time .............................................................................................................................. 10
Sleep Timer ............................................................................................................................ 10
Maintenance ...................................................................................................................................... 11-13
Alert Notications / Errors ............................................................................................... 11
Check Lamp Life ................................................................................................................... 12
Order Replacement Lamps and Ballasts ...................................................................... 12
Changing Lamps and Ballasts ........................................................................................ 12
Reset Lamp Life .................................................................................................................... 12
Cleaning .................................................................................................................................. 13
UV-CDoseVerication..........................................................................................................13
Operating .................................................................................................................................................. 14
Contact Information .............................................................................................................................. 15

2
INTRODUCTION
Health and wellbeing is a critical component to sustain an enjoyable life. It’s why the
quality of the air we breathe and cleanliness of the items we touch every day matters.
The germicidal properties featured in the BioShift Pass-Through UV-C Germicidal
Chamber oer a proven and eective way to inactivate harmful micro-organisms. The
BioShift chamber is designed and approved for industrial and commercial uses, and is
not to be used in residential or home settings.
The BioShift chamber is a sanitation tool made easy to use alongside additional cleaning
eorts. It helps meet a wide range of end-user needs by limiting cross contamination
through the import of pathogens on everyday items like cell phones, eye glasses, and
tools.
Veried to inactivate common pathogens by a nationally recognized testing laboratory
specializing in antimicrobial, biocidal and virucidal eectiveness, the BioShift chamber
uses UV-C radiation that has been extensively researched for more than 40 years.
Note: All bacteria and viruses tested to date respond to UV-C radiation, however it is mostit is most
eective on hard surface objects.eective on hard surface objects. It may not inactivate bacteria, viruses and pathogens, in
areas of objects that are not exposed to the proper intensity and duration of UV-C radiation.
Thus,the BioShiftPass-Through UV-CGermicidalChamber ismosteectively usedinaddition
and as a complement to disinfection products and procedures, and NOT as a replacement.

3
SPECIFICATIONS
Dimensions
Outside 25.8” wide x 30.7” deep x 19.7”high (655 x 780 x 500 mm)
Weight 121 lbs (55 kg)
Functional
Operating Power / Current 110V: 137W / 1.3 A, 240V: 140W / 63 mA
Standby Power / Current 110V: 6W / 130 mA, 240V: 9W / 100mA
Input Voltage 110-240VAC, 50/60 Hz (voltage uctuation ±10%)
Transient over voltages allowed up to category II
Temporary over voltages allowed to occur on mains supply
Power Connection Connect to branch circuit rated 20A max
Fuse Protection 5x20mm, Slow Blow, 10A, 250V
Note: Disconnect main power supply before replacing fuse.
Débranchez l’alimentation principale avant de remplacer le
fusible.
Environmental
Operating 41°F (5 °C) to 104 °F (40 °C) temperature
Maximum relative humidity 80% for temperatures up to 88°F
(31°C), decreasing linearly to 50% relative humidity at 104° F (40°C)
Note: Under 41°F (5°C) temperature must run warm-up cycle before
disinfecting. See Operating section.
Storage -20 °F (-28 °C) to 140 °F (60 °C) temperature, 10-95% humidity
Note: Allow unit to reach operating temperature before use.
Pollution Degree 2
UV-C Light Source
Germicidal Lamps 30W UV-C Lamps (4)
Output 254 nm UV-C Light
Chamber Components
Controller See Touchscreen Display section.
Emergency Switch Located on both sides of the machine, buttons turn OFF
chamber in case of emergency (re, smoke, etc.).
Tray / Reective Liner The tray and reective liner rest inside the bottom of the
chamber and are removable for easy cleaning.
Windows The tempered glass windows are opaque to UV-C.
Germicidal Lamps There are four (4) 30W germicidal UV-C lamps.
Magnet Securely holds doors in closed position while running.
Door Gasket Seals chamber during operation to keep light from escaping.

4
RISK OF UV
EXPOSURE CAUTION BIOHAZARD
SAFETY
Definition of Symbols
Warning
• It is possible that emissions from this product may interfere with some sensitive
appliances when placed nearby or in the same circuit as those appliances. The
user should be aware of this potential and take appropriate measures to avoid
interference.
• Not all materials are UV-C safe. UV-C rays can cause physical damage to products.
If products are excessively warm when they are removed after cleaning, they may
have been damaged by the UV-C.
• Do not put humans or live animals in the chamber.
• Do not allow children in or near the chamber.
• Do not place ammable liquid(s) in chamber.
Lamps
The lamps inside emit short wave UV-C radiation. Overexposure to direct or reected
UV-C light can cause severe damage to the eyes and skin. Never look into an illuminated
UV-C lamp without proper eye protection. The chamber windows provide a safe way to
view inside chamber without the risk of UV-C exposure.
Use caution when handling and changing lamps, as they are subject to fracturing. The
lamps contain a small amount of mercury, a chemical known to the state of California
to cause birth defects or other reproductive harm. The mercury is contained inside the
lamp and will not be released unless the lamp is damaged. Use appropriate PPE when
handling.
The lamps are sensitive to the oils in human skin, always handle with gloves.
Disposal and Recycling
All components must be disposed of in accordance with state and local laws. Refer to
lamprecycle.org for more information.
Visit www.once.lighting/bioshift-warnings or scan the QR code for
additional warning information.

5
Note: If the equipment is used in a manner not specied by the manufacturer, the protection
provided by the equipment may be impaired.
SAFETY
Features
Emergency Stop The safety switch can be found on either side of the chamber and
can be used at any time to stop the operation. Pressing EMERGENCY
STOP disconnects all power.
Open Door(s) BioShift chamber will not operate when the doors are open. The
doors cannot be opened during cycle time unless EMERGENCY
STOP is pressed. Both doors cannot be opened at the same time
unless EMERGENCY STOP is pressed.
Interlock Logic The clean (controller side) door will remain locked until a cycle is
complete.When complete, the clean door will remain unlocked until
the dirty (start button side) door is opened, or a new cycle is started.
If a cycle is interrupted, it will start over at the beginning. The dirty
door will remain locked anytime the clean door is open. Pressing the
EMERGENCY STOP will unlock both doors.
Start Button Illuminates blue when ready to start cycle.
Chamber The sealed chamber is meant to protect users from UV-C radiation.
Window The tempered glass windows are opaque to UV-C.
Controller The controller has a countdown timer which allows the user to
monitor Lamp Life, replacement recommended after 1000 cycles,
3000 hours, or after a failed Dose Verication Test (see Maintenance
section).

INSTALLATION
The BioShift chamber comes with four (4) padded feet on each corner to allow for easy
placement on any sturdy and hard, non-moving surface. If installing as a pass-through
unit, a 30”x 20” wall cut-out is recommended. Note: The BioShift chamber can be installed
in dry locations only (Pour emplacements secs seulement). Product is approved for indoor
use at an altitude up to 2000m.
1. Use two people to carefully lift the BioShift chamber into place.
2. Plug supplied power cord into standard electrical outlet. Note: Alternate power
cords not permitted.
Removal
Always de-energize/disconnect power before moving.
6

1
3
4
2
5
7
TOUCHSCREEN DISPLAY
The touchscreen display is located on the clean side of the BioShift chamber.
Home Screen Components
(1) Cycle Time Display
(2) Chamber Start / Stop
(3) Chamber Status
(4) Settings
(5) Maintenance

8
TOUCHSCREEN DISPLAY
Located under the Maintenance button.
Maintenance Screen Components
(1) View Lamp Life Remaining
(2) Reset Lamp Life
(3) View Lamp Replacement Info
(4) Run 100mJ/cm2Dose Test
(5) Run 250mJ/cm2Dose Test
(6) Run 1000mJ/cm2Dose Test
1
4
2
3
5
6

9
1
4
2
3
TOUCHSCREEN DISPLAY
Located under the Home screen Settings button.
Settings Screen Components
(1) View Set Lamp Cycle
(2) Set Lamp Cycle
(3) Set Sleep Time
(4) Expired Lamp Life
(5) Contact ONCE®
Table of contents