Omron FinsGateway User manual

Page: 1
FinsGateway Modem Module User’s Manual
©
©©
© Copyright OMRON Corporation 1999 All Rights Reserved
Copyright OMRON Corporation 1999 All Rights ReservedCopyright OMRON Corporation 1999 All Rights Reserved
Copyright OMRON Corporation 1999 All Rights Reserved
FinsGateway
FinsGatewayFinsGateway
FinsGateway
Modem Module
Modem ModuleModem Module
Modem Module
User
UserUser
User’
’’’s Manual
s Manuals Manual
s Manual
First Version
November, 1999
OMRON Corporation

Page: 2
FinsGateway Modem Module User’s Manual
©
©©
© Copyright OMRON Corporation 1999 All Rights Reserved
Copyright OMRON Corporation 1999 All Rights ReservedCopyright OMRON Corporation 1999 All Rights Reserved
Copyright OMRON Corporation 1999 All Rights Reserved
Contents
1
11
1 Introduction
IntroductionIntroduction
Introduction ................................
................................................................
................................................................
................................................................
................................................................
................................................................
................................3
33
3
2
22
2 System Requireme
System RequiremeSystem Requireme
System Requirements
ntsnts
nts ................................
................................................................
................................................................
................................................................
.................................................
..................................
.................4
44
4
3
33
3 Setting the PLC Modem
Setting the PLC ModemSetting the PLC Modem
Setting the PLC Modem................................
................................................................
................................................................
................................................................
..............................................
............................
..............5
55
5
3.1 Communications Settings for the PLC Modem............................................................................... 5
3.2 Serial Communications Driver Settings.......................................................................................... 7
4
44
4 Operation
OperationOperation
Operation ................................
................................................................
................................................................
................................................................
................................................................
................................................................
....................................
........
....8
88
8
4.1 Registering Telephone Numbers...................................................................................................... 8
4.2 Serial Communications Driver Settings........................................................................................ 10
4.3 Close the Line ................................................................................................................................. 11
5
55
5 Caution
CautionCaution
Caution................................
................................................................
................................................................
................................................................
................................................................
................................................................
......................................
............
......12
1212
12
5.1 Communications Settings............................................................................................................... 12
5.2 Speed Setting.................................................................................................................................. 12
5.3 Connecting the PLC Modem........................................................................................................... 13
5.4 Send the AT Command................................................................................................................... 13
6
66
6 Troubleshooting
TroubleshootingTroubleshooting
Troubleshooting................................
................................................................
................................................................
................................................................
.........................................................
..................................................
.........................14
1414
14
©Copyright OMRON Corporation 1995,1996-1998,1999 All Rights Reserved.
FinsGateway was developed using Microsoft Visual C++ Version 5.0 and Version 4.1, Borland Delphi Version 2.0,
and Microsoft FrontPage98.
Copyrights of the FinsGateway manual and software are owned by OMRON Corporation, except the following
items.
FinsGateway is released containing the following items copyrighted by Microsoft Corporation. These are:
ATL.DLL; MFC42.DLL; MSVCRT.DLL; MSVCP50.dll; and OLEAUT32.dll. These modules included in
FinsGateway are redistributed based on a license agreement between Microsoft Corporation and OMRON
Corporation. Under this license agreement, these modules cannot be distributed by the customer.
FINS and FinsGateway are trademarks of OMRON Corporation.
Microsoft, Windows, WindowsNT, and Visual C++ are registered trademarks of Microsoft Corporation.
Pentium and Intel are registered trademarks of Intel Corporation.
IBM is a registered trademark of International Business Machines Corporation.
All corporate names and product names mentioned in this manual are trademarks or registered trademarks of
each company.
The symbols äand âare omitted in this document.

Page: 3
FinsGateway Modem Module User’s Manual
©
©©
© Copyright OMRON Corporation 1999 All Rights Reserved
Copyright OMRON Corporation 1999 All Rights ReservedCopyright OMRON Corporation 1999 All Rights Reserved
Copyright OMRON Corporation 1999 All Rights Reserved
1 Introduction
The Modem Module is an add-on software for FinsGateway remote communication.
You can develop a remote PLC data acquisition application quickly and easily using the
modem module.
Analog Phone Line
FinsGateway + Modem Module
PLC
PLC

Page: 4
FinsGateway Modem Module User’s Manual
©
©©
© Copyright OMRON Corporation 1999 All Rights Reserved
Copyright OMRON Corporation 1999 All Rights ReservedCopyright OMRON Corporation 1999 All Rights Reserved
Copyright OMRON Corporation 1999 All Rights Reserved
2 System Requirements
The Modem Module is an add-on software for FinsGateway. Therefore, the environment must
support the operation of FinsGateway. The following system specifications are recommended
to operate the Modem Module.

Page: 5
FinsGateway Modem Module User’s Manual
©
©©
© Copyright OMRON Corporation 1999 All Rights Reserved
Copyright OMRON Corporation 1999 All Rights ReservedCopyright OMRON Corporation 1999 All Rights Reserved
Copyright OMRON Corporation 1999 All Rights Reserved
3 Setting the PLC Modem
3 – 1 Communications Settings for the PLC Modem
Modems can detect the communication settings automatically to communicate with the
computer when the computer sends the AT command to the modem. That is why you do not
need to set the communications settings for the computer modem.
However, the PLC modem cannot detect the communications settings, because PLC is not a
computer and does not send the AT command to the modem. The communications settings for
the PLC modem must match the settings of the computer modem and the PLC.
Modems can detect the
communications settings
automatically to communicate with
the computer when the computer
sends the AT command to the
modem.
The communications settings
for the PLC modem must
match the settings of the
computer modem and the
PLC.

Page: 6
FinsGateway Modem Module User’s Manual
©
©©
© Copyright OMRON Corporation 1999 All Rights Reserved
Copyright OMRON Corporation 1999 All Rights ReservedCopyright OMRON Corporation 1999 All Rights Reserved
Copyright OMRON Corporation 1999 All Rights Reserved
1. Plug the PLC modem into the COM port of the computer.
2. Click on the Start button, point to Programs, point to FinsGateway, and point to PLC Modem
Setup.
3. Select the COM port for the modem in the COM port box.
4. Select the communications settings in the dialog to match the communications settings of the
PLC.
default: BaudRate: 9600bps, Data Bits: 7, Stop Bit: 1, Parity: Even
5. Click on the [Set] button.
The PLC modem setting is done. Unplug the modem from the computer and plug it into the
PLC.

Page: 7
FinsGateway Modem Module User’s Manual
©
©©
© Copyright OMRON Corporation 1999 All Rights Reserved
Copyright OMRON Corporation 1999 All Rights ReservedCopyright OMRON Corporation 1999 All Rights Reserved
Copyright OMRON Corporation 1999 All Rights Reserved
3 – 2 Serial Communications Driver Settings
1. Exit PLC Reporter if it is running.
2. Click on the Start button, point to Programs, point to FinsGateway, and point to Serial
Communications Setup.
3. Click the Communications Line tab and select the check box of the COM port for the modem
to add the phone line.
4. Click [OK] to close the dialog.
5. Set the network address for the added phone line if necessary.

Page: 8
FinsGateway Modem Module User’s Manual
©
©©
© Copyright OMRON Corporation 1999 All Rights Reserved
Copyright OMRON Corporation 1999 All Rights ReservedCopyright OMRON Corporation 1999 All Rights Reserved
Copyright OMRON Corporation 1999 All Rights Reserved
4 Operation
Register a telephone number to identify each destination modem and PLC.
4 – 1 Registering Telephone Numbers
1. FgwTapiCaller Settings
Click on the Start button, point to Programs, point to FinsGateway, and point to FgwTapiCaller.
2. Select Phone Line Type
Click on the Dialing Properties button. Select Tone dialing or Pulse dialing in the Dialing
Properties dialog to set the dialing type.
Click the Tone dialing or Pulse
dialing in the Dialing Properties
dialog to select the dialing type.

Page: 9
FinsGateway Modem Module User’s Manual
©
©©
© Copyright OMRON Corporation 1999 All Rights Reserved
Copyright OMRON Corporation 1999 All Rights ReservedCopyright OMRON Corporation 1999 All Rights Reserved
Copyright OMRON Corporation 1999 All Rights Reserved
3. Type the name and the telephone number of the destination to call in the telephone number
setup dialog.
You can enter a comma (, ), or – in the telephone number box to make the telephone
number easy to identify.
4. Click on the Modem Setup button in the telephone number setup dialog to start the modem
settings dialog.
Select the modem in the Modem to use field and set the communication settings to match
the settings of the remote PLC.
5. Click the Unit setup button in the telephone number setup dialog to start the modem settings
dialog.
Select the COM port which connecting the Modem.
6. Confirm that the new telephone number appears in the telephone numbers dialog
7. Click [OK] to finish the telephone number setup. Click [cancel] to cancel the settings and
quit.

Page: 10
FinsGateway Modem Module User’s Manual
©
©©
© Copyright OMRON Corporation 1999 All Rights Reserved
Copyright OMRON Corporation 1999 All Rights ReservedCopyright OMRON Corporation 1999 All Rights Reserved
Copyright OMRON Corporation 1999 All Rights Reserved
4 – 2 Serial Communications Driver Settings
1. Dial the destination.
After the telephone number is registered, Click the [Dial] button and start dialing. You can
monitor status and perform one-shot communications with a remote PLC after dialing is
completed successfully.
The line status dialog appears when dialing. After dialing is completed successfully, the dialog
is minimized automatically.
Click the icon to see th
e
dialog again.