b) Control Panel and Location
The control is located on the top panel of the DEFEND NV1050 near the front of the unit.
c) Power control
The control button on the furthest left-hand side of the control panel is for switching the device
ON/OFF; the power button. The power button clearly illuminated with a ‘blue’ LED to indicate
when the device is on. The ‘blue’ LED is illuminated when in the ‘ON’ mode and non-illuminated
when the device is in the ‘OFF’ mode.
d) Air flow control
The control allows the user to select the device airflow using selection buttons ‘+’ on the right-
hand side for incrementing the air flow setting to a higher airflow, and ‘-’ on the left-hand side
for decreasing the air flow setting to a lower air flow.
The air flow setting level is clearly indicated by illuminating a series of blue LEDs in sequence
(from left to right) according to the speed setting (e.g. two LEDs for speed II, three LEDs for
speed III). The DEFEND NV1050 has 5 selectable air flow speeds.
e) Save airflow to memory
There is an ability to save a selected airflow to memory, so the device will revert to the last
known speed on power-on.
The last known speed can be saved to memory by holding the ON/OFF (1) and ‘-‘ (3) buttons for
three seconds. To revert to factory settings and to clear the air speed memory the ON/OFF (1)
and ‘+’ (5) buttons are held for three seconds.
f) HEPA Filter replacement test
The HEPA Filter replacement test indicator is for information purposes only.
The Filter replace button is on the furthest right-hand side of the panel for testing the filter back
pressure. Upon pressing the filter back pressure test, the device shall override the air flow
setting to speed 5 air flow for testing the filter for a period of approx. 30 seconds.
The test button shall remain backlit illuminated ‘blue’ LED while the device is testing the air
pressure.
The device shall indicate that the HEPA filter need to be inspected for replacement by
illuminating the test button in ‘Orange’ or a continuous LED light in ‘Orange’
The device shall indicate that the HEPA filter does not need to be inspected by illuminating the
test button in ‘green’ or a continuous light in ‘green’.