netvox R718CT2 User manual

Mode:R718CT2/CK2/CR2
Wireless Thermocouple Interface for T/K/R Type Thermocouple
Wireless Thermocouple Interface for
T/K/R Type Thermocouple R718CT2/CK2/CR2
User Manual

1
Table of Content
1. Introduction.............................................................................................................................................................................................................................................................. 0
2. Appearance............................................................................................................................................................................................................................................................... 1
3. Main Features...........................................................................................................................................................................................................................................................1
4.Set up Instruction...................................................................................................................................................................................................................................................... 2
5. Data Report .......................................................................................................................................................................................................................................................... 3
6. Installation................................................................................................................................................................................................................................................................4
7. Important Maintenance Instruction..........................................................................................................................................................................................................................4
1. Introduction
R718CK2 (nickel-chromium-nickel silicon thermocouple): its use temperature is -40 ~ +375℃, with good linearity, large thermoelectromotive force,
high sensitivity, stability, can not be used directly at high temperature for sulfur, reducing or reducing It is not recommended for use in weak oxidizing
atmospheres in oxidizing alternating atmospheres and in vacuum.
R718CT2 (copper-copper-nickel thermocouple): its use temperature is -40 ~ +125℃, it is used in the temperature range of -40~0℃, and the stability is
better.
R718CR2 (precious metal thermocouple): Its temperature is 0 ~ +1100℃. The R type thermocouple has the highest accuracy, the best stability, wide
temperature range and long service life in the thermocouple series. It has good physical and chemical properties, good thermoelectric potential stability
and high oxidation resistance at high temperatures, and is suitable for oxidizing and inert atmospheres.
LoRa Wireless Technology:
LoRa is a wireless communication technology dedicated to long distance and low power consumption. Compared with other communication methods,
LoRa spread spectrum modulation method greatly increases to expand the communication distance. Widely used in long-distance, low-data wireless
communications. For example, automatic meter reading, building automation equipment, wireless security systems, industrial monitoring. Main
features include small size, low power consumption, transmission distance, anti-interference ability and so on.
LoRaWAN:
LoRaWAN uses LoRa technology to define end-to-end standard specifications to ensure interoperability between devices and gateways from different
manufacturers.

2
2. Appearance
Fig.1 Appearance
3. Main Features
Adopt SX1276 wireless communication module
2 ER14505 battery AA SIZE (3.6V / section) parallel power supply
Body protection class IP65/IP67, external thermocouple sensor protection grade (T-type thermocouple IP67; K-type thermocouple IP60; N-type
thermocouple IP60; R-type thermocouple IP60)
The base is attached with a magnet that can be attached to a ferrous object
2-way thermocouple detection
Compatible with LoRaWANTM Class A
Frequency hopping spread spectrum
Configuration parameters can be configured via a third-party software platform
Applicable to third-party platforms: Actility / ThingPark, TTN, MyDevices /Cayenne
Low power consumption, longer battery life support*:
Battery life is determined by sensor reporting frequency and other variables,
please refer to http://www.netvox.com.tw/electric/electric_calc.html
On the website, users can find battery life of various models in different configurations.

3
4.Set up Instruction
On/Off
Power on Insert batteries.
(users may need a flat blade screwdriver to open)
Turn on Press and hold the function key for 3 seconds till the green indicator flashes once.
Turn off
(Restore to factory setting) Press and hold the function key for 5 seconds till green indicator flashes for 20 times.
Power off Remove Batteries.
Note:
1. Remove and insert the battery; the device is at off state by default.
2. On/off interval is suggested to be about 10 seconds to avoid the interference of capacitor inductance and other
energy storage components.
3. At 1st-5th second after power on, the device will be in engineering test mode.
Network Joining
Never joined the network
Turn on the device to search the network to join.
The green indicator stays on for 5 seconds: success
The green indicator remains off: fail
Had joined the network
(Not at factory setting
mode)
Turn on the device to search the previous network to join.
The green indicator stays on for 5 seconds: success
The green indicator remains off: fail
Fail to join the network
(when the device is on)
First two mins: wake up every 15 seconds to send request.
After two mins: enter sleeping mode and wake up every 15 minutes to send request.
Note: Suggest to remove batteries if the device is not used to save power.
Suggest to check the device verification information on the gateway
or consult your platform server provider.
Function Key
Press and hold for 5
seconds
Restore to factory setting / Turn off
The green indicator flashes for 20 times: success
The green indicator remains off: fail
Press once The device is in the network: green indicator flashes once and sends a report
The device is not in the network: green indicator remains off
Sleeping Mode
The device is on and in the
network
Sleeping period: Min Interval.
When the reportchange exceeds setting value or the state changes: send a data report according to Min Interval.
The device is on but not in
the network
First two mins: wake up every 15 seconds to send request.
After two mins: enter sleeping mode and wake up every 15 minutes to send request.
Note: Suggest to remove batteries if the device is not used.
Suggest to check device verification on gateway.
Low Voltage Warning
Low Voltage 3.2V

4
5. Data Report
The device will immediately send a version package report and a report data with temperature and humidity and voltage values.
The device sends data in the default configuration before any configuration is done.
Maximum time: Max Interval (default 900 seconds)
Minimum time: Min Interval (default 900 seconds) (by default, the current voltage value is detected per Min Interval)
Default reportchange:
Battery --- 0x01 (0.1V)
TempChange----0x01 (1°C);
Note: The real data sending cycle will be programmed before shipment.
The interval between two reports must be the minimum time
Data report configuration and sending period are as following:
Example#1 based on MinTime = 1 Hour, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange=0.1V
MaxTime MaxTime
Sleeping(MinTime) Sleeping(MinTime)
Note: MaxTime=MinTime. Data will only be report according to MaxTime (MinTime) duration regardless BtteryVoltageChange value.
Example#2 based on MinTime = 15 Minutes, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange= 0.1V.
MaxTime
Sleeping(MinTime) sleeping sleeping sleeping
0H 15th M 30th M 45th M1H 2H
Min Interval
(Unit:second)
Max Interval
(Unit:second) Reportable Change Current Change≥
Reportable Change
Current Change <
Reportable Change
Any number between 1~65535 Any number between
1~65535 Can not be 0. Report
per Min Interval
Report
per Max Interval
Wakes up and
collects data
3.6V
Does not report
Wakes up and
collects data
3.6V
Does not report
Wakes up and
collects data
3.6V
Does not report
Wakes up and
collects data
REPORTS
3.6V
Wakes up and
collects data
REPORT 3.6V
Wake up and collects data
REPORTS 3.6V
Wakes up and collects data
REPORTS 3.5V
Wakes up and collects data
REPORTS 3.6V

5
Example#3 based on MinTime = 15 Minutes, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange= 0.1V.
MaxTime
sleeping sleeping ...
0H 15th M30th M45th M 1H 1H 10th M1H 25th M 1H 40th M 1H 55th M2H 10th M
Notes :
1) The device only wakes up and performs data sampling according to MinTime Interval. When it is sleeping, it does not collect data.
2) The data collected is compared with the last data reported. If the data variation is greater than the ReportableChange value, the device reports according to MinTime interval. If the data
variation is not greater than the last data reported, the device reports according to MaxTime interval.
3) We do not recommend to set the MinTime Interval value too low. If the MinTime Interval is too low, the device wakes up frequently and the battery will be drained soon.
4) Whenever the device sends a report, no matter resulting from data variation, button pushed or MaxTime interval, another cycle of MinTime/MaxTime calculation is started.
6. Installation
Thermocouples have positive and negative poles, with the + mark on the bare device as the direction, the second and third holes as a group, the 4th and
5th holes as a group, the 2nd and 4th holes connect to the positive (red line) of the thermocouple, the third and fifth holes connect to the negative (black
line) of thermocouples. This product comes with a waterproof function. When using it, you can attach the back side to the iron surface, or use screws to
fix both ends to the wall.
Note: To install the battery, use a tool such as a screwdriver to open the battery cover.
7. Important Maintenance Instruction
Your device is a product of superior design and craftsmanship and should be used with care. The following suggestions will help you use the warranty
service effectively.
•Keep the equipment dry. Rain, moisture, and various liquids or moisture may contain minerals that can corrode electronic circuits. In case the
device is wet, please dry it completely.
•Do not use or store in dusty or dirty areas. This can damage its detachable parts and electronic components.
•Do not store in excessive heat. High temperatures can shorten the life of electronic devices, destroy batteries, and deform or melt some plastic parts.
•Do not store in a cold place. Otherwise, when the temperature rises to normal temperature, moisture will form inside, which will destroy the board.
•Do not throw, knock or shake the device. Rough handling of equipment can destroy internal circuit boards and delicate structures.
•Do not wash with strong chemicals, detergents or strong detergents.
•Do not apply with paint. Smudges can block debris in detachable parts and affect normal operation.
•Do not throw the battery into a fire to prevent the battery from exploding. Damaged batteries may also explode.
All of the above suggestions apply equally to your device, battery and accessories. If any device is not working properly.
Please take it to the nearest authorized service facility for repair.
Wakes up and
collects data
REPORTS 3.6V
Wakes up and collects data
3.5V |3.5-3.6|=0.1
REPORTS 3.5V
Wakes up and
collects data
3.5V Does not
report
Wakes up and
collects data
3.5V Does not
report
Wakes up and
collects data
3.5V Does not
report
Wakes up and collects data
3.5V Does not report
Wakes up and
collects data
3.5V Does not
report
Wakes up and
collects data
REPORTS 3.5V
Wakes up and
collects data
3.6V Does not
report
Users push the button,
REPORTS 3.5V.
Recalculate MaxTime.
Other manuals for R718CT2
1
This manual suits for next models
2
Table of contents
Other netvox Recording Equipment manuals

netvox
netvox R718IB2 User manual

netvox
netvox R718H User manual

netvox
netvox R718J2 User manual

netvox
netvox R718J User manual

netvox
netvox R718CT2 User manual

netvox
netvox R718IB2 User manual

netvox
netvox R718CK User manual

netvox
netvox R718H2 User manual

netvox
netvox R718T User manual

netvox
netvox R718IB User manual

netvox
netvox R718IA User manual

netvox
netvox R718T2 User manual

netvox
netvox R718KA2 User manual

netvox
netvox ZigBee ZL01B User manual

netvox
netvox R718J User manual

netvox
netvox R718T2 User manual

netvox
netvox R718T User manual

netvox
netvox ZigBee Z103A User manual

netvox
netvox R718IA User manual

netvox
netvox R718H User manual