NAPCO IQ PROFILER - User manual

Advanced Profiling Technology
PASSIVE INFRARED SENSOR
INSTALLATION INSTRUCTIONS
Napco Security Systems, Inc.
333 Bayview Avenue, Amityville, New York 11701
For Sales and Repairs, (800) 645-9445
RWI1017 08/00
1
TM

Now it just takes a minute and a screwdriver to install
the smart microprocessor-based PIR that profiles
targets against a built-in library of 1200+ false alarm
and alarm sources for verified detection -- NAPCO’s IQ
Profiler Sensor!
• 50 lb. Pet Immunity (22.7kg) *
• Maximum Range: 50 x 50 Feet (15.2m x 15.2m)
• Superior False Alarm Discrimination and Unique Dual
Focal Lenses in Advanced Bi-Optic Contour Case.
• IQ Profiling: Each detected signal is profiled against
Napco’s proprietary built-in library of false alarm
signals and real alarm signals for maximum
accuracy.
• Shielded High-Performance Aspheric Lenses plus
Look-Down/Creep Zone
• Sensor Chamber prevents insect, draft, and dust
interference.
• Quick Mount: A quarter-turn of a screwdriver in the
back housing’s mounting disk and the unit embeds
itself in any corner in seconds, with innovative self-
projecting, fast anchoring wall pins.
• Quick Wire: “Snap-Down” Terminal Strips hold
wires fast (No screws!) Just insert stripped wires in
each and snap down (speaker-jack style).
• Wall & Swivel Mounting (SVL2), too.
* Pet Immunity has not been evaluated by UL. 2

SPECIFICATIONS
Coverage (l x w): 50' x 50' (15.2m x 15.2m) at 20°C (68°F),
typical. (with High Sensitivity Jumper “SEN”
installed)
30' x 35' (9.1m x 10.6m) at 20°C (68°F),
typical. (with Normal Sensitivity)
Operating Temperature: -10° to +50°C (14°F to 122°F)
Mounting: Wall or corner, 6.5’ to 8.5' max.
Alarm Output: Normally-Closed Form-A Relay
Contact Ratings: 100mA, 24VDC with internal 10 Ohm current-
limiting resistor
POWER-SUPPLY REQUIREMENTS
Note: This unit is intended for operation from a power source that
provides a 4 hour battery backup in the event of a power failure.
Filtered Dc: 10.6 to 16V DC nominal with battery backup from
control panel.
Current Drain: 28mA (idle or alarm) at 12VDC (nominal) 33mA
(idle or alarm) at 16VDC (nominal).
PHYSICAL
Dimensions: 4.5 in x 2.5 in x 1.8 in (HxWxD)
Shipping Weight: 6oz.
3

• Bi-Optic Contour Case and Dual focal lenses
provide exceptional distance profiling:
• “Far Field Lens” allows for detection of large
objects and ignores small targets nearby
• “Near Field Lens” allows for discrimination of
small targets nearby
4
NAPCO 10/00 Pats. Pending
IQ Profiler is a trademanrk of NAPCO

Locating the Detector
Corner mounting is preferred as it provides the best overall
coverage. Choose a corner where the path of an intruder will most
likely cross beams, as opposed to walking towards or away from
them. This lens is intentionally made with an 85 degree angle of
view, to help prevent curtains on windows from being in detection
zones.
Sources of heat, such as radiators and space heaters, do not
usually pose a problem as long as hot air from them does not
blow directly onto the detector. One exception to this is overhead
radiant heaters, these produce very high levels of infrared energy
and can heat the unit at some distance. Mount the unit as far from
these as possible. Do not mount the unit where the sun can shine
directly on it. Mount it away from the direction of sunlight.
Standard Installation
Protection pattern
Top View
7’
Side View 50’
50’
85°
5

Installations with Pets
The IQ Profiler will provide good immunity to small to medium
sized pets in most applications. The pet or pets should be less
than 50 lbs. and less than 24” tall. Several small cats are
acceptable. If you have three or more large ones, we
recommend that the NAPCO C200AP dual technology sensor
be used. Mount the unit at a height of 7 ft. Following are 2
installation techniques, one for small pets and one for larger pets.
NOTE: For all Pet Installations, the (SEN) jumper should be off
(normal sensitivity). NOTE: Pet Immunity has not been
evaluated by UL.
Small Pet Avoidance
If you are protecting a typical room area which may include small
pets or rodents (no larger than 20 lbs. total weight), locate the
detector at a height of 7 ft. and avoid placement that would allow
the pets to get within 6 ft. of the detector. It may be necessary to
mask a zone of the lens with the supplied material if a staircase is
closer than 20 ft. to the detector and directly in a zone. The
detector should be mounted at a height of 7 ft. with the PC Board
mountingheight index set to
3. Small Pet Avoidance
Protection Pattern
(Jumper SEN off)
35’
Top View
85° 7’
Side View 35’ 6

Large Pet Avoidance
The IQ Profiler can be configured to avoid detection of pets up to
50 pounds and less than 24” tall. Remove or mask the small look
down lens just below the PIR sensor. Configured in this manner,
the IQ Profiler will allow a larger pet to freely move about, but still
retain the sensitivity required to detect an intruder. The detector
should be mounted at a height of 7 ft. with the PC Board mounting
height index set to 3.
NOTE: Pet Immunity has not been evaluated by UL.
Large Pet Avoidance
Protection pattern
(Jumper SEN off and Animal
Attenuation Mask installed)
35’
Top View
85° 7’
Side View 35’
7

Preparing to Mount the IQ Profiler
1 Insert screwdriver into slot on bottom of unit to remove top of
housing
2 Remove the circuit board from the housing by gently pushing
outward on the PC board height index tab which is located on
the left edge of the housing.
3 Determine the wire entry point to be used. The housing
provides an entry point on the top of the enclosure. Any
unused screw hole recess may also be used for wire entry.
Determine which entry is most convenient and punch out or
remove the thin plastic section.
4 Feed wire through punch out hole.
PC board height
index tab
Swivel mount
punch through
Install Quick
corner mounting slot
Wire entry
punch through
Flat wall mount
screw holes
Standard Corner
mount screw
Install Quick
mounting pins (2)
IQ Profiler base detail 8

Install Quick Corner Mounting Instructions
The IQ Profiler incorporates a patented Install Quick
Corner Mounting feature which allows quick corner
mounting on standard sheet rock (drywall) surfaces.
1 Firmly hold the base of the housing against the corner of the
wall in the location in which it is to be mounted.
2 Insert a large bladed screwdriver into the Install Quick corner
mounting slot and twist clockwise approximately 45 degrees
(1/8 turn). The unit has a built in stop which will prevent over
turn. The 2 Install Quick mounting pins will project from each
side of the base, securing the unit to the wall.
3 Install circuit board and proceed with installation. When
installing circuit board, gently push PC Board indexing tab
outward to allow the board to rest on the shelf slots of
housing. For standard installations, align the PCBoard index
designation 1 with the dimple on index tab.
Note: The Install Quick Corner Mounting method is designed for
standard sheet rock walls. For corner mounting on harder wall
surfaces, such as plaster or brick, push through the standard
corner mount holes and use the supplied screws to secure the
unit.
Caution: Use care not to project
the mounting pins while holding
the base in your hand. The pins
will pierce the skin causing injury.
The base must be held against
wall before projecting pins
Top View
9

Wiring the IQ Profiler using the Install Quick Terminals
The IQ Profiler incorporates innovative Install Quick wiring
terminals which allow wiring within seconds. Strip approx.
1/4” of insulation from the end of each wire, insert into the
top of the terminal and press the lever down to secure the
wire.
Wiring & Terminal Descriptions
Refer to the wiring diagram and terminal descriptions, connect the
appropriate wire to the corresponding terminal. When you have
finished wiring the terminals seal the opening around the wire entry
hole and any other unused holes with the supplied sealer.
Power (Terminals 1 [+] & 2 [-]): Connect 12 volt regulated or
unregulated power.
N.C. (Terminals 3 & 4) Normally closed alarm relay: Connect
to zone wiring, either detection of an intruder or loss of power will
cause relay to open.
TRBL (Terminal 5) (Optional) Active low (open collector
transistor) auxiliary output, can be configured to provide an
activation on high temperature, low temperature or self test failure.
Using the appropriate jumper settings this output can activate on
any combination of the the above items including all or none.
Tamper (Terminals 6 & 7): With lens cover in place, the contacts
are closed.
1/4
10
Other manuals for IQ PROFILER -
1
Table of contents
Other NAPCO Accessories manuals

NAPCO
NAPCO PIR600 User manual

NAPCO
NAPCO DUAL TECH GEMC-BSLC-DT-L User manual

NAPCO
NAPCO GEM-EZM4/8 Installation and operating instructions

NAPCO
NAPCO GEMC-BSLC-PIR User manual

NAPCO
NAPCO PIR1710 User manual

NAPCO
NAPCO CF5530 User manual

NAPCO
NAPCO ADVANCED ADAPTIVE C-200AP User manual

NAPCO
NAPCO GEM-EZM4/8 User manual

NAPCO
NAPCO WIZARD IIe User manual

NAPCO
NAPCO GEM-ACM1D User manual