MTU MS15027/02E Instruction sheet

Operating Instructions
Gas engine
12 V 4000 Lx4
16 V 4000 Lx4
MS15027/02E

Engine model kW/cyl. Application group
12V4000L64 130 kW/cyl. 3A, continuous operation, unrestricted
16V4000L64 130 kW/cyl. 3A, continuous operation, unrestricted
Table 1: Validity overview
© 2015 Copyright MTU Friedrichshafen GmbH
This publication is protected by copyright and may not be used in any way, whether in whole or in part, without the prior
written consent of MTU Friedrichshafen GmbH. This particularly applies to its reproduction, distribution, editing, transla-
tion, microfilming and storage or processing in electronic systems including databases and online services.
All information in this publication was the latest information available at the time of going to print. MTU Friedrichshafen
GmbH reserves the right to change, delete or supplement the information provided as and when required.

Table of Contents
1 Safety
1.1 Important provisions for all products 5
1.2 Personnel and organizational requirements 7
1.3 Safety regulations for startup and operation 8
1.4 Safety requirements for startup and
operation, special instructions for
applications with gaseous fuel 9
1.5 Safety regulations for maintenance and
repair work 10
1.6 Safety requirements for maintenance and
repair work, special instructions for
applications with gaseous fuel 13
1.7 Fire prevention and environmental
protection, fluids and lubricants, auxiliary
materials 14
1.8 Fire prevention and environmental
protection, fluids and lubricants, auxiliary
materials, special instructions for
applications with gaseous fuel 16
1.9 Standards for safety notices in the text 17
1.10 Transport 18
2 Product Summary
2.1 Engine overview 19
2.2 Engine side and cylinder designations 21
2.3 Main engine dimensions 22
2.4 Firing order 23
2.5 Technical Data 24
2.5.1 12 V 4000 L64, 16 V 4000 L64 engine data,
fuel optimized ("TA-Luft") 24
2.5.2 12V 4000 L64, 16V 4000 L64 engine data,
emissions-optimized (1/2 "TA-Luft") 28
2.6 Monitoring, Control and Regulation
Equipment 32
2.6.1 Gas engine system – Overview 32
2.6.2 Purpose of the units 34
3 Operation
3.1 Runtimes at partial load 36
3.2 Putting the engine into operation after
extended out-of-service periods (>3 months) 37
3.3 Putting the engine into operation after
scheduled out-of-service-period 38
3.4 Control, starting and stopping sequences 39
3.5 Engine – Start 41
3.6 Operational checks 42
3.7 Emission values – Check 43
3.8 Engine – Shutdown 44
3.9 Emergency engine shutdown 45
3.10 After stopping the engine – Engine remains
ready for operation 47
3.11 After stopping the engine – Putting the
engine out of operation 48
4 Maintenance
4.1 50-hours check 49
4.2 Maintenance schedule reference table [QL1] 50
5 Troubleshooting
5.1 Fault messages - Key 51
5.2 Fault messages in log for genset controller 53
5.3 Engine Control Unit – Fault messages 111
6 Task Description
6.1 Engine 150
6.1.1 Engine – Barring manually 150
6.1.2 Machine room – Check for smell of gas 151
6.2 Crankcase Breather 152
6.2.1 Oil separator – Filter replacement 152
6.3 Ignition System 154
6.3.1 Spark plug – Replacement 154
6.3.2 Spark plug – Removal 155
6.3.3 Spark plug – Installation 156
6.3.4 Spark plug connector – Replacement 158
6.3.5 Spark plug connector – Removal 159
6.3.6 Spark plug connector – Installation 160
6.3.7 Ignition system – Ignition timing check 162
6.4 Valve Drive 163
6.4.1 Valve projection – Measurement 163
6.4.2 Valve gear – Lubrication 166
6.4.3 Valve clearance – Check and adjustment 167
6.4.4 Cylinder head cover ‒ Removal 169
6.4.5 Cylinder head cover ‒ Installation 170
6.5 Gas System 171
6.5.1 Gas supply - Checking gas lines for leaks 171
6.6 Air Filter 172
6.6.1 Air filter – Replacement 172
6.6.2 Air filter – Removal and installation 173
6.7 Lube Oil System, Lube Oil Circuit 174
6.7.1 Engine oil – Level check 174
6.7.2 Engine oil – Change 175
6.7.3 Engine oil – Sample extraction and analysis 176
6.8 Oil Filtration / Cooling 177
MS15027/02E 2015-04 | Table of Contents | 3
DCL-ID: 0000028920 - 004

6.8.1 Engine oil filter – Replacement 177
6.9 Coolant Circuit, General, High-Temperature
Circuit 178
6.9.1 Engine coolant – Level check 178
6.9.2 Engine coolant – Change 179
6.9.3 Engine coolant – Draining 180
6.9.4 Engine coolant – Filling 182
6.10 Low-Temperature Circuit 183
6.10.1 Mixture coolant level – Check 183
6.10.2 Mixture coolant – Change 184
6.10.3 Mixture coolant – Draining 185
6.10.4 Mixture coolant – Filling 186
6.11 Wiring (General) for Engine/Gearbox/Unit 187
6.11.1 Engine cabling – Check 187
6.11.2 Sensors – Overview 188
7 Appendix A
7.1 Abbreviations 192
7.2 MTU Onsite Energy contact person / service
partner 194
8 Appendix B
8.1 Special Tools 195
8.2 Index 199
4 | Table of Contents | MS15027/02E 2015-04
DCL-ID: 0000028920 - 004

1 Safety
1.1 Important provisions for all products
Nameplate
The product is identified by nameplate, model designation or serial number and must match with the
information on the title page of this manual.
Nameplate, model designation or serial number can be found on the product.
All EU-certified engines delivered by MTU come with a second nameplate. When operating the machine
in the EU: The second nameplate must be affixed in a prominent position as described in the accompa-
nying specifications.
General information
This product may pose a risk of injury or damage in the following cases:
• Incorrect use
• Operation, maintenance and repair by unqualified personnel
• Modifications or conversions
• Noncompliance with the safety instructions and warning notices
Correct use
The product is intended for use in accordance with its contractually-defined purpose as described in the
relevant technical documents only.
Intended use entails operation:
• Within the permissible operating parameters in accordance with the (→ Technical data)
• With fluids and lubricants approved by the manufacturer in accordance with the (→ Fluids and Lubri-
cants Specifications of the manufacturer)
• With spare parts approved by the manufacturer in accordance with the (→ Spare Parts Catalog/MTU
contact/Service partner)
• In the original as-delivered configuration or in a configuration approved by the manufacturer in writ-
ing (including engine control/parameters)
• In compliance with all safety regulations and in adherence with all warning notices in this manual
• With maintenance work performed in accordance with the (→ Maintenance Schedule) throughout the
useful life of the product
• In compliance with the maintenance and repair instructions contained in this manual, in particular
with regard to the specified tightening torques
• With the exclusive use of technical personnel trained in commissioning, operation, maintenance and
repair
• By contracting only workshops authorized by the manufacturer to carry out repair and overhaul
Any other use is considered improper use. Such improper use increases the risk of injury and damage
when working with the product. The manufacturer shall not be held liable for any damage resulting from
improper, non-intended use.
Modifications or conversions
Unauthorized changes to the product represent a contravention of its intended use and compromise
safety.
Changes or modifications shall only be considered to comply with the intended use when expressly au-
thorized by the manufacturer. The manufacturer shall not be held liable for any damage resulting from
unauthorized changes or modifications.
MS15027/02E 2015-04 | Safety | 5
TIM-ID: 0000040530 - 006

Emission regulations and emission labels
Responsibility for compliance with emission regulations
Modification or removal of any mechanical/electronic components or the installation of additional com-
ponents including the execution of calibration processes that might affect the emission characteristics
of the product are prohibited by emission regulations. Emission control units/systems may only be
maintained, exchanged or repaired if the components used for this purpose are approved by the manu-
facturer.
Noncompliance with these regulations will invalidate the design type approval issued by the emissions
regulation authorities. The manufacturer does not accept any liability for violations of the emission reg-
ulations. The maintenance schedules of the manufacturer must be observed over the entire life cycle of
the product.
Replacing components with emission labels
Emission labels are attached to all MTU engines. These must remain on the engine throughout its op-
erational life.
Engines used exclusively in land-based, military applications other than by US government agencies are
excepted from this proviso.
Please note the following when replacing components with emission labels:
• Appropriate emission labels must be affixed on spare parts.
• Emission labels may not be transferred from old components to new ones.
• Emission labels on old components must be removed and destroyed.
6 | Safety | MS15027/02E 2015-04
TIM-ID: 0000040530 - 006

1.2 Personnel and organizational requirements
Organizational measures of the user/manufacturer
This manual must be issued to all personnel involved in operation, maintenance, repair or transporta-
tion.
Keep this manual handy in the vicinity of the product such that it is accessible to operating, mainte-
nance, repair and transport personnel at all times.
Personnel must receive instruction on product handling and maintenance on the basis of this manual
with a special emphasis on safety requirements and warnings.
This is particularly important in the case of personnel who only occasionally perform work on or around
the product. This personnel must be instructed repeatedly.
Personnel requirements
All work on the product shall be carried out by trained and qualified personnel only:
• Training at the Training Center of the manufacturer
• Qualified personnel specialized in mechanical and plant engineering
The operator must define the responsibilities of the personnel involved in operation, maintenance, re-
pair and transport.
Working clothes and personal protective equipment
Wear proper protective clothing for all work.
When working, always wear the necessary personal protective equipment (e.g. safety footwear, ear pro-
tectors, protective gloves, goggles, breathing protection). Observe the information on personal protec-
tive equipment in the respective activity description.
MS15027/02E 2015-04 | Safety | 7
TIM-ID: 0000040531 - 004

1.3 Safety regulations for startup and operation
Safety requirements for startup
Install the product correctly and carry out acceptance in accordance with the manufacturer's specifica-
tions before putting the product into service. All necessary approvals must be granted by the relevant
authorities and all requirements for initial startup must be fulfilled.
When putting the product into operation, always ensure that
• All personnel is clear of the danger zone surrounding moving parts of the machine.
Electrically-actuated linkages may be set in motion when the Engine Control Unit is switched on.
• All maintenance and repair work has been completed.
• All loose parts have been removed from rotating machine components.
• All safety equipment is in place.
• No persons wearing pacemakers or any other technical body aids are present.
• The service room is adequately ventilated.
• Keep clear of the service room during the first operating hours. Hazardous gases may occur as a re-
sult of the combustion of paints or oils.
• The exhaust system is leak-tight and that the gases are vented to atmosphere.
• Protect battery terminals, generator terminals or cables against accidental contact.
• Check that all connections have been correctly allocated (e.g. +/- polarity, direction).
Immediately after putting the product into operation, make sure that all control and display instruments
as well as the monitoring, signaling and alarm systems are working properly.
Safety requirements for operation
The operator must be familiar with the controls and displays.
The operator must be familiar with the consequences of any operations performed.
During operation, the display instruments and monitoring units must be permanently observed with re-
gard to present operating status, violation of limit values and warning or alarm messages.
Malfunctions and emergency stop
The procedures for emergencies, in particular, emergency stop, must be practiced regularly.
The following steps must be taken if a malfunction of the system is detected or reported by the system:
• Inform supervisor(s) in charge.
• Analyze the message.
• Respond to the emergency appropriately, e.g. execute an emergency stop.
Operation
Do not remain in the operating room when the product is running for any longer than absolutely neces-
sary.
Keep a safe distance away from the product if possible. Do not touch the product unless expressly in-
structed to do so following a written procedure.
Do not inhale the exhaust gases of the product.
The following requirements must be fulfilled before the product is started:
• Wear ear protectors.
• Mop up any leaked or spilled fluids and lubricants immediately or soak up with a suitable binder
agent.
Operation of electrical equipment
When electrical equipment is in operation, certain components of these appliances are electrically live.
Observe the safety instructions for these devices.
8 | Safety | MS15027/02E 2015-04
TIM-ID: 0000040533 - 008

1.4 Safety requirements for startup and operation, special
instructions for applications with gaseous fuel
Safety requirements for startup
Whenever the product is started, always ensure that:
• The operator has fulfilled the requirement to: Check the gas train.
Gas system, requirements
Gas supply shut-off: The incomplete machine does not have its own gas supply shutoff device. This
must be realized by the plant designer to suit site conditions.
The connection to the gas supply network is established by the plant designer in accordance with re-
quirements of the DVGW (DVGW490, G490/I). The plant designer must use certified gas trains for the
fuel supply to the product and connection to the gas supply network. The connection conditions and
dimensions must be coordinated with the manufacturer.
In flow direction, gas trains have:
• a manual shutoff valve
• a gas filter
• two gas shutoff valves
• a pressure regulating device
The gas train must be fitted with an automatic leak check.
The gas shutoff valves are activated via two different paths from the control system, whereby one gas
shutoff valve respectively is activated via one of the paths.
Gas trains must be monitored to detect minimum pressure.
The plant designer must ensure that the gas train is positioned directly in front of the engine, yet a max-
imum of 3 meters before the interface of the engine. The interface is the flange in front of the gas vol-
ume regulator of the product.
In the case of network supply pressures higher than 100 mbar, additional equipment is required on the
gas train.
The gas pressure regulator must be equipped with an approved safety shut-off valve and a safety dis-
charge valve to ensure safety in case of excessive outlet pressure at the pressure regulator. Gas dis-
charge must be routed to a safe area (to atmosphere).
If the gas supply is connected to a vessel or if gases containing oxygen are used, the gas train must be
equipped with a temperature-monitored flame arrester.
MS15027/02E 2015-04 | Safety | 9
TIM-ID: 0000040550 - 003

1.5 Safety regulations for maintenance and repair work
Safety regulations prior to maintenance and repair work
Have maintenance or repair work carried out by qualified and authorized personnel only.
Allow the product to cool down to less than 50 °C (risk of explosion for oil vapors, fluids and lubricants,
risk of burning).
Relieve pressure in fluid and lubricant systems and compressed-air lines which are to be opened. Use
suitable collecting vessels of adequate capacity to catch fluids and lubricants.
When changing the oil or working on the fuel system, ensure that the service room is adequately venti-
lated.
Never carry out maintenance and repair work with the product in operation, unless:
• It is expressly permitted to do so following a written procedure.
• The product is running in the low load range and only for as long as absolutely necessary.
Lock-out the product to preclude undesired starting, e.g.
• Start interlock
• With hydraulic starting system: shut off supply line.
Attach “Do not operate” sign in the operating area or to control equipment.
Disconnect the battery. Lock out circuit breakers.
Close the main valve on the compressed-air system and vent the compressed-air line when air starters
are fitted.
Disconnect the control equipment from the product.
Use special tools if they are specified for the relevant work.
Elastomer components (e.g. engine mounts, damping elements, couplings and V-belts) must not be
painted. They may only be installed after painting the engine or must be covered before painting work is
carried out.
The following applies to starters with copper-beryllium alloy pinions:
• Wear a respirator mask (filter class P3). Do not blow out the interior of the flywheel housing or the
starter with compressed air. Clean the flywheel housing inside with a class H dust extraction device.
• Observe the safety data sheet.
Safety regulations during maintenance and repair work
Take special care when removing ventilation or plug screws from the product. Cover the screw or plug
with a rag to prevent fluids escaping under pressure.
Take care when draining hot fluids and lubricants (risk of burning).
Use only proper and calibrated tools. Observe the specified tightening torques during assembly or dis-
assembly.
Carry out work only on assemblies or plants which are properly secured.
Make sure components or assemblies are placed on stable surfaces. Adopt suitable measures to avoid
that components/tools fall down .Use the specified lifting equipment for all components.
Never use lines for climbing.
Keep fuel injection lines and connections clean.
Carry out appropriate cleaning procedures to clean and inspect components requiring special cleanness
(e.g. components carrying oil, fuel, or air).
Always seal connections with caps or covers if a line is removed or opened.
Fit new seals when re-installing lines.
Avoid damaging lines, particularly the fuel lines.
10 | Safety | MS15027/02E 2015-04
TIM-ID: 0000040535 - 008
This manual suits for next models
1
Table of contents
Other MTU Engine manuals

MTU
MTU 12 V 4000 T95 x User manual

MTU
MTU 20 V 4000 G23 User manual

MTU
MTU 12V2000Gx5 User manual

MTU
MTU 8V 4000 Lx2 x User manual

MTU
MTU 8 V 2000 M9x User manual

MTU
MTU 20 V 4000 M73 x User manual

MTU
MTU 16V2000M72 User manual

MTU
MTU 12 V 4000 T94 User manual

MTU
MTU 20V4000M73 series User manual

MTU
MTU 8V4000M*3 series User manual

MTU
MTU 12V4000L32FB User manual

MTU
MTU 8 V 2000 M50A User manual

MTU
MTU M015710/04E User manual

MTU
MTU 12 V 4000 L62FB User manual

MTU
MTU 12 V 4000 Mx4 User manual

MTU
MTU 12V4000M93 series User manual

MTU
MTU 8 V 2000 M40A User manual

MTU
MTU 16V4000R43 User manual

MTU
MTU 16 V 2000 G56 S User manual

MTU
MTU 8 V 2000 M40A User manual