TYPE – voltage regulator connection type. The name of the protocol BSS is displayed, as well as
12 types of LIN protocol: A1, A2, A3, A4, B1, B2, B3, B4, C3, D1, D2, E1.
EXCITATION – current value in the winding coil of alternator excitation. This parameter is read
from the voltage regulator by LIN protocol (the parameter is displayed in %).
ERRORS – indicator of errors that the regulator transmits to engine control unit. The following
errors may happen:
• EL – electric;
• МЕС – mechanic;
• ТН – overheating.
Once the error is detected, it’s highlighted by red.
SUPPLIER – the voltage regulator manufacturer.
SUPP. ID – the voltage regulator ID generated by the manufacturer.
BACK – exit from the diagnostics mode.
When you choose the mode of the diagnostics of the following alternator types: SIG, RLO, RVC,
C KOREA, P/D, C JAP. alternator types, the following information can be displayed (fig. 8):
Figure 8. Alternator diagnostics window:
SIG, RLO, RVC, C KOR., P/D, C JAP.
1– Diagnosed alternator type.
2– buttons -V and +V modify the value of the set stabilizing voltage of alternator. Press once to
change the value with 0.2V pitch.