Movisens LightMove 4 Quick guide

LightMove 4
Ambient Light and Physical Activity
Sensor
Operating and Safety Instructions

2
Imprint
LightMove 4 Operating and Safety Instructions
Version: 21.08.2019
movisens GmbH
Augartenstraße 1
76137 Karlsruhe
Germany
Phone: +49 721 381344-0
Fax: +49 721 381344-90
Internet: www.movisens.com
E-Mail: [email protected]om
© Copyright: movisens GmbH

3
1Welcome!
Dear customer,
Thank you for choosing the Ambient Light and Physical Activity Sensor
LightMove 4 from movisens. With this sensor, you get the newest
technology for mobile monitoring of ambient light and physical activity in
everyday life.
Please read this manual completely and thoroughly before bringing the
measurement system into service!
In this manual you will find the most relevant operating instructions and the
safety instructions.
Please find the full movisens documentation here:
docs.movisens.com
If you have any further questions, don’t hesitate to contact us. It is our
pleasure to help you:
Phone: +49 721 381344-0
E-Mail: support@movisens.com

4
2Intended use
LightMove 4 is a scientific research instrument that captures the ambient
light, physical activity and other secondary parameters derivable from these
measurement signals. LightMove 4 is designed and tailored for the use in
research applications.
The Ambient Light and Physical Activity Sensor LightMove 4 is not a
medical device!
The sensor measures the physical activity of a person based on the
acquisition of acceleration in three dimensions and atmospheric air
pressure. Moreover the sensor also records the rotation rate and the
ambient temperature. The ambient light is detected via a color light sensor.
This sensor allows the measurement of illuminance (brightness) over a wide
range (darkness to sunlight), color temperature measurement and light
source type detection (enabled by an integrated additional IR channel).
The sensor configuration occurs via a USB 2.0 connection to a Windows PC
using the Sensor Manager software.
3Explanation of Symbols
Caution.
Read the manual and the safety instructions to
find out about possible hazards and the needed
actions to avoid these hazards!

5
4Safety Instructions
Please follow these safety instructions. Improper use of the product may
impair/affect the protection provided by the product and cause product
damage or personal/physical injury:
!LightMove 4 is not a medical device. Do not use it for a
medical purpose.
!Only use LightMove 4 for the intended use.
!Carefully read and follow the cleaning instructions.
!For long term measurements (> 1 day) we suggest wearing
pauses of at least 20min per day.
!If any problems occur by wearing the sensor, band, belt or
attachments (e.g. pressure marks, skin irritations or other
discomfort), stop using the system immediately.
!Only use the LightMove 4 under the specified environmental
conditions.
!To charge the battery of LightMove 4, only use USB 2.0
standard compatible devices.
!Charge the sensor only at ambient temperatures below 45°C.
!The use of the cradle is only intended for indoor use.
!Never open LightMove 4.
!The battery of LightMove 4 may only be changed by the
manufacturer.

6
5Scope of Delivery
The following components are included in delivery:
Article
Order No.
LightMove 4
Ambient Light and Physical Activity Sensor,
Cradle,
Micro USB cable,
Belt Clip,
Operating and safety instructions
10401
To be able to do measurements a PC is needed in addition to the scope of
delivery.
6Accessories
The following accessories can be ordered optionally:
Article
Order No.
Wrist Band (S)
Size: S
Wrist Measurement: 13 to 16 cm
30431
Wrist Band (M)
Size: M
Wrist Measurement: 15 to 18 cm
30432
Wrist Band (L)
Size: L
Wrist Measurement: 17 to 23 cm
30433
Wrist Band (XL)
30434

7
Size: XL
Wrist Measurement: 20 to 28 cm
USB Charger
USB Charger for 110-240V
30100
USB Hub
USB Hub 2.0, 7 Ports
30101
Micro USB Cable
30102
Cradle 4
Cradle with Micro USB interface
30400
7Consumables
The following consumables can be ordered optionally:
Article
Order No.
Meliseptol Rapid (250 ml)
Ready-to-use alcoholic
disinfectant for spraying or
wiping.
40410
8Description of the Sensor
LightMove 4 is designed to be worn with a wrist band on the non-
dominant arm.

8
LightMove 4 is also equipped with a Bluetooth Smart interface. The sensor
can be used in conjunction with a gateway or a mobile phone for live
applications. The Bluetooth Smart interface is activated in the default
configuration of the sensor. To deactivate this interface, a firmware update
is required.
The axes of the integrated acceleration sensor are described in the
following figure:
9User interface and indicators
LightMove 4 is equipped with a multi-colored LED to show the status of
the sensor:
Status-LED
Meaning
Flashing red (once
per second)
The sensor is active and records
data

9
Flashing red
slowly (every two
seconds)
Delayed recording active
Flashing green
The sensor is connected to a PC or
a charger. The battery is fully
charged.
Flashing blue
The sensor is connected to a PC or
a charger. The battery is actually
being charged.
Flashing magenta
The sensor is active and records
data. It is connected to a charger.
The battery is actually being
charged.
Flashing yellow
The sensor is active, records data. It
is connected to a charger. The
battery is fully charged.
Flashing blue fast
(three times per
second)
The battery is low, sensor will turn
off soon.
Flashing red fast
(three times per
second)
An Error occurred. Reset the sensor
with the Reset Sensor Program. If
the sensor doesn’t stop flashing,
please contact the manufacturer.
No LED active
The sensor is inactive.
Combinations of red and green blinking as well as red and blue blinking are
possible with the appropriate combination of the above described
meanings.

10
LightMove 4 features a vibration alarm. It vibrates two times when a
marker is set. During measurement a marker can be set by double tapping
on the front of the sensor.
10 Software Installation
Please ensure that your PC fulfills the requirements:
⚫A PC with Microsoft Windows 7 or higher, 64bit
⚫USB 2.0 Port
⚫Administrator rights during installation
⚫A minimum of 300 MB free space on hard disc
Step 1: Download the SensorManager from the movisens Website
Step 2: Double click the file “movisens_SensorManager_Setup.exe“
✓The Installation runs automatically in the background. After successful
installation, shortcuts are created in the Windows Start Menu under the
entry “movisens SensorManager”.
Step 3: Download the UnisensViewer from the movisens Website:
Step 4: Double click the file “UnisensViewer_Setup_Full.exe“
✓The Installation runs automatically in the background. After successful
installation, a shortcut “UnisensViewer” is created in the Windows Start
Menu.
11 Handling
This chapter describes how to prepare a measurement and how to attach
the sensor to a test person. Furthermore you get information on how to
save, delete and analyze data from the sensor.
Table of contents
Other Movisens Accessories manuals