Introduction
Microchip’s PD-9001GCO, PD-9501GCO, and PD-9601GCO is a single-port IEEE® 802.3bt Gigabit PoE outdoor
midspan that offers a cost-effective, IEEE® 802.3at/bt compliant solution that guarantees 30W/60W/90W of power,
and ensures safe and reliable operation in outdoor environments for standard PoE data terminal. These midspans
support 10/100/1000 Mbps data rates and are powered through a wide range of AC inputs (100 VAC to 240 VAC).
These midspans are IP67-rated and have an extended temperature range to be installed outdoors. In a typical
installation, the midspans provide power to outdoor devices such as WLAN AP, WLAN Mesh, or an IP Camera.
These units offers surge protection for both the AC and the PoE ports ensuring that the indoor equipment is protected
from outdoor surges.
PoE midspan powers devices that are PoE enabled or equipped to receive PoE. These devices are called Powered
Devices (PDs).
Note: This user guide contains installation information for the PD-9001GCO, PD-9501GCO, and PD-9601GCO PoE
midspan units. These units are referred to as PD-9x01GCO PoE midspan units in the following section of this
document.
Features
PoE Midspans offer the following key features:
• Outdoor Rated: IP67
• Extended Temperature Range
• Supports 10/100/1000 Mbps Data Rates
• Standards Compliant: IEEE 802.3at/bt
• Plug and Play Installation
• Includes Integrated Surge/Lightning Protection
© 2022 Microchip Technology Inc.
and its subsidiaries
User Guide DS50003422A-page 1

Table of Contents
Introduction.....................................................................................................................................................1
Features.................................................................................................................................................. 1
1. Standards and Safety Guidelines............................................................................................................4
1.1. Electrical Compatibility Approvals................................................................................................ 4
1.2. Safety Standard Approvals...........................................................................................................4
1.3. CE Marking...................................................................................................................................4
1.4. GS/D Compliance.........................................................................................................................4
1.5. Surge/Lightning Protection...........................................................................................................4
1.6. Dust and Water Protection........................................................................................................... 5
1.7. Other Standards and Approvals...................................................................................................5
1.8. Safety Information........................................................................................................................ 5
2. Information en Matière de Sécurité......................................................................................................... 6
2.1. Directives Générales....................................................................................................................6
2.2. Mises en Garde............................................................................................................................6
3. PoE Midspan Unit Installation................................................................................................................. 7
3.1. Parts List...................................................................................................................................... 7
3.2. Additional Tools............................................................................................................................ 7
3.3. Installation.................................................................................................................................... 8
4. Installation of Cables.............................................................................................................................14
4.1. AC Power Cable Installation.......................................................................................................14
4.2. RJ45 Cable Installation.............................................................................................................. 15
4.3. Data and Power Connection...................................................................................................... 17
5. Troubleshooting.....................................................................................................................................18
5.1. Preliminary Steps....................................................................................................................... 18
5.2. Troubleshooting Steps................................................................................................................18
6. Specifications........................................................................................................................................ 19
6.1. Environmental Specifications..................................................................................................... 19
6.2. Electrical Specifications..............................................................................................................19
6.3. Interface..................................................................................................................................... 19
7. Technical Support..................................................................................................................................20
8. Revision History.................................................................................................................................... 21
Microchip Information...................................................................................................................................22
The Microchip Website..........................................................................................................................22
Product Change Notification Service.................................................................................................... 22
Customer Support................................................................................................................................. 22
Microchip Devices Code Protection Feature.........................................................................................22
Legal Notice.......................................................................................................................................... 22
Trademarks........................................................................................................................................... 23
Quality Management System................................................................................................................ 24
PD-9x01GCO/AC
© 2022 Microchip Technology Inc.
and its subsidiaries
User Guide DS50003422A-page 2

1. Standards and Safety Guidelines
This chapter describes the standards and safety guidelines for the product.
1.1 Electrical Compatibility Approvals
Microchip’s PoE midspan units complies with the following standards:
PD-9001GCO PD-9501GCO PD-9601GCO
EN61000-4-5 Class5 (6KV on AC Lines)
EN55032
EN55035
FCC Part 15
— — EN61000-3-2
EN61000-3-3
VCCI
1.2 Safety Standard Approvals
Microchip’s PD-9x01GCO PoE midspan units meet the following safety standards. Consult Microchip for a complete
list of safety certifications.
• UL/IEC/EN 62368-1
• UL60950-22
1.3 CE Marking
CE marking on this product indicates that this product complies with the Electromagnetic Compatibility (EMC)
Directive.
1.4 GS/D Compliance
GS marking on this product indicates that the product complies with the German Product Safety Act.
D marking on this product indicates that the product complies with the Denmark Product Safety Act.
1.5 Surge/Lightning Protection
Microchip’s PD-9x01GCO PoE midspan units are designed to me the following requirements.
• GR-1089-CORE Lightning Protection Requirements
• ITU K.21 Lightning Protection—Enhanced Level
PD-9x01GCO/AC
Standards and Safety Guidelines
© 2022 Microchip Technology Inc.
and its subsidiaries
User Guide DS50003422A-page 4

1.6 Dust and Water Protection
Microchip’s PD-9x01GCO PoE midspan units are designed according to the following requirements.
• IEC60529, Level IP67
• NEMA 250, Level 4x
1.7 Other Standards and Approvals
Microchip’s PD-9x01GCO PoE midspan units are designed according to the following requirements.
• PD-9001GCO/PD-9501GCO: IEEE 802.3at and IEEE 802.3af (PoE) Standards
• PD-9601GCO: IEEE 802.3bt (PoE) Standards
• RoHS Compliant
• WEEE Compliant
• REACH Compliant
1.8 Safety Information
Read the safety information before using the PoE midspan unit.
1.8.1 General Guidelines
Read the following safety information before carrying out any installation, removal, or maintenance procedure on the
PoE midspan. Warnings contain directions to be followed for the safety of personal and product.
1.8.2 Warnings
• Read installation instructions in 3. PoE Midspan Unit Installation before connecting midspan unit to its power
source.
• Follow basic electricity safety measures when connecting the PoE midspan unit to its power source.
• Only trained and qualified personnel must be allowed to install, replace, and service this equipment.
• A voltage mismatch can damage the equipment and can pose a fire hazard. If voltage indicated on the label is
different from the power outlet voltage, do not connect midspan unit to this outlet.
• All wiring and connections must conform to NFPA 70 (NEC).
• Power supply cord must not be attached to the building surface or run through walls, ceilings, floors, and similar
openings in the building structure.
• Measures must be taken to prevent physical damage to the power supply cord, including proper routing.
• Data and Data and Power ports of the midspan unit are shielded RJ45 data sockets. They cannot be used as
Plain Old Telephone Service (POTS) sockets. Only connect RJ45 data connectors to these sockets.
• When disposing this product, follow all local laws and regulations.
PD-9x01GCO/AC
Standards and Safety Guidelines
© 2022 Microchip Technology Inc.
and its subsidiaries
User Guide DS50003422A-page 5

2. Information en Matière de Sécurité
Lire les informations suivantes en matière de sécurité avant d'utiliser d'activer l'alimentation sur votre appareil
Ethernet unité midspan.
2.1 Directives Générales
Lire les informations suivantes en matière de sécurité avant d'installer ou enlever quoi que ce soit, ou procéder à
l'entretien de l'alimentation de votre appareil Ethernet midspan. Les mises en garde contiennent des instructions qui
doivent être suivies pour la sécurité des personnes et du produit. Suivre les instructions soigneusement.
2.2 Mises en Garde
• Lire les instructions d'installation dans 3. PoE Midspan Unit Installation avant de connecter le midspan à une
source d'alimentation.
• Suivre les mesures de sécurité électrique de base lors de la connexion de l'injecteur PoE à sa source
d'alimentation.
• Seul du personnel formé et qualifié doit être autorisé à installer, remplacer et entretenir cet équipement.
• Une disparité de voltage peut endommager l'équipement et constituer un risque d'incendie. Si le voltage indiqué
sur l'étiquette est différent du voltage de la source d'alimentation, ne pas connecter le midspan à cette prise.
• Tout le câblage et les connexions doivent être conformes à la norme NFPA 70 (NEC).
• Le cordon d'alimentation ne doit pas être fixé à la surface du bâtiment ni passer à travers les murs, les plafonds,
les planchers et les ouvertures similaires de la structure du bâtiment.
• Des mesures doivent être prises pour éviter tout dommage physique au cordon d'alimentation, y compris son
acheminement correct.
• Les ports Data et Data et Power du PoE midspan sont des prises de données blindées RJ45. Elles ne peuvent
pas être utilisées comme prises de service téléphonique traditionnel. Connecter seulement des connecteurs de
données RJ45 à ces prises. Le câblage Ethernet connexe doit être limité à l'intérieur de l'immeuble.
• Pour disposer/jeter ce produit, suivre les lois et règlements locaux.
PD-9x01GCO/AC
Information en Matière de Sécurité
© 2022 Microchip Technology Inc.
and its subsidiaries
User Guide DS50003422A-page 6

3. PoE Midspan Unit Installation
This chapter describes the procedure to install the midspan unit.
Note: Do not use a cross-over cable between the PoE midspan output port and the load device.
Warnings:
1. Take extra care when connecting the AC power inlet terminals, so that N, L, and Ground are connected to the
proper polarity.
2. Ensure that the AC power is within the allowed range.
3. Earth ground screw must be connected to earth ground in all types of installations.
3.1 Parts List
The following table lists the parts included in the kit.
Quantity Component
1 30W/60W/90W midspan unit, outdoor model
1 AC female connector
1 Quick Installation Guide
3.2 Additional Tools
The following table lists the additional tools required to install the midspan unit.
Quantity Part
1 Screwdriver
1 Wire stripper
1 Solid Wrench No. 27 or Adjustable Wrench
PD-9x01GCO/AC
PoE Midspan Unit Installation
© 2022 Microchip Technology Inc.
and its subsidiaries
User Guide DS50003422A-page 7

3.3 Installation
This section describes the prerequisites and available installation options for the midspan unit.
The following figure shows the overview of the midspan unit.
Figure 3-1. Product Overview—Front View
Figure 3-2. Product Overview—Top View
Figure 3-3. Product Overview—Bottom View
3.3.1 Prerequisites
Note the following before mounting the PoE midspan unit to a fixed location:
• To ensure weather-proof connection in order to meet IEC60529 level IP67. PoE midspan AC power plug needs
to be connected to a weather-proof AC power source box.
• Do not cover the midspan or block the airflow to the PoE with any foreign objects.
• Keep the midspan away from excessive heat and free from vibration.
• Ensure that the cable length from the Ethernet network source to the terminal does not exceed 100 meters (333
feet). The midspan is not a repeater and does not amplify the Ethernet data signal.
• The midspan has no ON-OFF switch, simply plug the midspan to an AC power source.
• PoE midspan AC power lines must be connected to the socket-outlet that shall be installed near the equipment
and be easily accessible.
PD-9x01GCO/AC
PoE Midspan Unit Installation
© 2022 Microchip Technology Inc.
and its subsidiaries
User Guide DS50003422A-page 8

3.3.2 Earth Ground Connection
Note: Connect the midspan to ground only if replacing pre-assembled ground cable.
1. Connect the chassis bolt to the earth ground point on the rear of the midspan.
2. Connect the other end of the ground wire to earth ground at your installation point.
3. Tighten the screw to 1.1 Nm to 1.7 Nm.
Figure 3-4. Earth Ground Connection
To Earth Ground
PD-9x01GCO/AC
PoE Midspan Unit Installation
© 2022 Microchip Technology Inc.
and its subsidiaries
User Guide DS50003422A-page 9

3.3.3 Installation Options
Following are the two options available for the installation of these midspan units:
1. Wall Mounting—PoE midspan unit can be mounted on a wall/bench (all kind of flat surfaces such as wood,
brick, concrete and other) using the mounting holes.
CAUTION
Use only a solid mounting surface to install the midspan unit, do not install on drywall or
plasterboard walls.
2. Pole Mounting—Using the optional mounting kit.
Note: The optional mounting kits are not provided with the midspan unit. Contact 7. Technical Support for
more information on ordering the mounting kits (Part Number: PD-OUT/MBK/GCO or PD-OUT/MBK/ET).
3.3.3.1 Wall Mounting
Follow the procedure to mount the unit directly to a wall.
1. Using the screw holes of the midspan as a template, put marks on the mounting surface (a wall of wood, brick
or concrete) to mark drill points and drill four holes.
2. With the unit attached to the mounting surface, insert four mounting screws through the screw holes on the
unit and into the mounting surface.
Notes:
• For bricks or concrete wall, use anchor screws (5 mm x 40 mm), and for wooden wall, use wood screws
(5 mm x 40 mm).
• The screws are not provided with the kit.
3. Tighten each screw until the midspan unit is securely attached to the mounting surface.
185
118
185
118
185
118
12
34
Note: The dimensions in the above figure are in millimeters.
PD-9x01GCO/AC
PoE Midspan Unit Installation
© 2022 Microchip Technology Inc.
and its subsidiaries
User Guide DS50003422A-page 10
This manual suits for next models
3
Table of contents
Languages:
Other Microchip Technology Network Hardware manuals
Popular Network Hardware manuals by other brands

Matrix Switch Corporation
Matrix Switch Corporation MSC-HD161DEL product manual

B&B Electronics
B&B Electronics ZXT9-IO-222R2 product manual

Yudor
Yudor YDS-16 user manual

D-Link
D-Link ShareCenter DNS-320L datasheet

Samsung
Samsung ES1642dc Hardware user manual

Honeywell Home
Honeywell Home LTEM-PV Installation and setup guide