MFZ Ovitor CS 300 RM User manual

Operating Instructions for CS 300 RM Controls EN
CS 300 RM Gate Controls Rev. B 1.0 – 1

2 – CS 300 RM Gate Controls / Rev. B 1.0
1. Contents 3. General safety instructions
2. Key to symbols
Original operating instructions
−Protected by copyright.
−No part of this manual may be reproduced without our
prior approval.
−Subject to alterations in the interest of technical progress.
−All dimensions are given in millimetres.
−The diagrams in this manual are not to scale.
Guarantee
The function and safety of the equipment is only guaranteed
if the warning and safety instructions included in these opera-
ting instructions are adhered to.
MFZ Antriebe GmbH + Co. KG is not liable for personal injury
or damage to property if these occur as a result of the war-
nings and safety advice being disregarded.
Using the equipment for its intended purpose
The CS 300 RM control unit is intended exclusively for the
purpose of controlling tubular drives that have mechanical
limit switch systems.
Target group
Only qualied and properly trained electricians are allowed to
connect up, programme or service the control unit.
Qualied and trained electricians must have the following:
− Knowledge of the general and specic safety and accident-
prevention regulations
−Knowledge of the relevant electrical regulations
−Training in the use and care of appropriate safety equip-
ment
−The ability to recognise the risks associated with electricity
Instructions relating to installation and connection
−Before commencing electrical works, the system must be
disconnected from the power supply. Measures must be
taken to ensure that the power supply remains switched off
for the duration of the works.
−The local safety regulations must be observed.
−Power cables must be laid separately from control cables.
Danger of personal injury!
The safety instructions must be observed!
Warning! Danger to property!
The safety instructions must be observed!
Information
Special information
OR
Reference to other sources of information
1. Contents 2
2. Key to symbols 2
3. General safety instructions 2
4. Overview of products 3
5. Initial operation 5
6. Programming with the LED module 10
7. Programming with the LCD monitor 12
8. Navigator (LCD monitor only) 14
9. Overview of functions 16
10. Error messages and rectication 23
11. Technical data 24
12. EC Declaration of Incorporation 25
13. Appendix 26

EN
CS 300 RM Gate Controls / Rev. B 1.0 – 3
Regulations and test specications
The following regulations must be complied with when
connecting, programming or servicing the unit. (The list is not
exhaustive.)
Construction product standards
− EN 13241-1 (Products without re resistance or smoke
control characteristics)
−EN 12445 (Safety in use of power operated doors -
Test methods)
−EN 12453 (Safety in use of power operated doors -
Requirements)
−EN 12978 (Safety devices for power operated doors and
doors - Requirements and test methods)
EMC
−EN 55014-1 (Electromagnetic compatibility - Requirements
for household appliances)
−EN 61000-3-2 (Limits for harmonic current emissions )
− EN 61000-3-3 (Limitation of voltage changes, voltage uc-
tuations and icker in public low-voltage supply systems)
−EN 61000-6-2 (Electromagnetic compatibility (EMC) - Part
6-2: Generic standards - Immunity for industrial environ-
ments)
−EN 61000-6-3 (Electromagnetic compatibility (EMC) - Part
6-3: Generic standards - Emission standard for residential,
commercial and light-industrial environments)
Machinery Directive
−EN 60204-1 (Safety of machinery, electrical equipment of
machines, Part 1: General requirements)
−EN 12100-1 (Safety of machinery - Basic concepts, general
principles for design, Part 1: Basic terminology, methodo-
logy)
Low voltage
−EN 60335-1 (Household and similar electrical appliances -
Safety)
−EN 60335-2-103 (Particular requirements for drives for
gates, doors and windows)
Committee for Workplaces (Ausschuss für Arbeitsstätten -
ASTA)
−ASR A1.7 (Technical Regulations for workplaces - Doors
and gates)
4.1 Various options
The following package options are available for the CS 300
RM controls:
−CS 300 RM control unit with LCD monitor
−CS 300 RM control unit with LCD monitor in housing
−CS 300 RM control unit with LED module for setting the
OPEN and CLOSED door positions (no further settings are
possible).
−CS 300 RM control unit without LED module and without
LCD monitor (a module or monitor is required for adjusting
the settings)
All the above options can be tted with a plug-in weekly
timer (switch clock) and a plug-in radio receiver.
The following options are available for the housing:
−Housing unit with 3-button input unit CS
−Housing unit with 3-button input unit KDT
−Housing with ON/OFF key switch
−Housing with mains switch
−Housing with emergency off button
The operating instructions describe the connection options
and programming procedures for the following models:
−CS 300 RM control unit with LED board
−CS 300 RM control unit with attached LCD display board
4. Overview of products

4 – CS 300 RM Gate Controls / Rev. B 1.0
4. Overview of products
4.2 CS 300 RM main board
(with attached LCD display monitor)
Key:
X1: terminal block for mains
connection / motor
X3: terminal block for command
devices
X4: terminal block
safety devices / before-end
switch
X5: terminal block
relay
X6: terminals for internal ON-
OFF switch
X7: terminals for internal 3-but-
ton input unit
X8: socket for monitor
(under monitor)
X9: terminals for
radio receiver
X10: terminals for weekly timer
(switch clock)
X12: socket for external radio
receiver
X13: terminals for
CS 3-button input unit
H4: status display for safety edge
protection (SKS) – illumina-
ted when SKS is working
H6: Safety circuit status message
– lights up when the safety
circuit is closed
F1: 4A fuse

EN
CS 300 RM Gate Controls / Rev. B 1.0 – 5
5. Initial operation
5.1 General
Warning!
To guarantee that the equipment functions
properly, the following points must be
ensured:
The door is installed and operational.
- The MFZ tubular drive is installed and ready
for operation.
- The command and safety devices are instal-
led and ready for operation.
- The control housing with the CS 300 RM
control unit is installed.
Information:
For the installation of the gate/door, the MFZ
geared motor and the command and safety
devices, the relevant manufacturer’s instruc-
tions are to be adhered to.
5.2 Mains connection
Danger!
To ensure that the control unit functions pro-
perly, the following conditions must apply:
- The supply voltage must correspond to the
voltage shown on the type plate.
- The supply voltage must correspond to the
voltage of the door operator.
- If a permanent connection is to be made, an
all-pole mains switch must be installed.
Warning!
Before switching on the control unit for the
rst time, check to ensure that the cabling
works are complete and that all the motor
connections are secure at both the motor and
the control unit. All control voltage inputs are
separated galvanically from the mains power
supply.

6 – CS 300 RM Gate Controls / Rev. B 1.0
5. Initial operation
5.3 Assignment of connections for the motor
and the power supply
(terminal X1)
Terminal block X1
L1 N PE PE PE N U1 U2 S1 S2 S3 S4
M
230V / 1PH
230V / 1PH
S1-S4
Connection of mains switch (optional)
Connection:
Connect the control unit to the mains.
Connect the control unit to the motor.
Cable groups must be secured in place with a cable tie close
to their terminals.
Information:
Technical data, see page 24.
5.4 Assignment of connections for command
and safety devices
Command and safety devices can be connected to terminals
X3, X4 and X5.
Terminal block X3
- CLOSE button
- impulse button 1
- OPEN button
- STOP button
- Emergency off, slack rope switch,
wicket door contact, draw-in
protection
Terminal block X4
(for optoelectronic safety edge protection)
Part OPEN2
- safety edge protection
OPTO
- drive-through light
barrier3
- 24 V DC / 250 mA4
1 sequence control
2 button or selector switch
3 effective in down direction
4
for external switching devices (connection to terminals 1
and 2)
wt: white
gr: green
br: brown
1
2
3
4
5
6
7
8
9
10
+
-
wt
gr
br

EN
CS 300 RM Gate Controls / Rev. B 1.0 – 7
Terminal block X4
(for 8.2 kOhm safety edge protection)
- safety edge protec-
tion
- drive-through light
barrier -3
- 24 V DC / 250 mA4
Klemmleiste X4
(mit Vorendschalter für Reversierabschaltung)
- before-end switch
NO
Terminal block X4
(for 3-wire light barrier)
- 3-wire light barrier
Terminal block X5
(potential-free switch contacts)
- relay 1
- relay 2
- relay 3
- relay 4
8k2
1
2
3
4
5
6
7
8
9
10
24V
GND
1
2
3
4
5
6
7
8

8 – CS 300 RM Gate Controls / Rev. B 1.0
5. Initial operation
Key switch OPEN / CLOSE
- CLOSE
- OPEN
Impulse button
(sequence control)
- impulse button
Connection:
Connect any installed command and safety devices to the
control unit.
5.5 Connection examples for command and
safety devices (terminal X3)
OPEN / STOP / CLOSE buttons
(6-lead solution)
- CLOSE button
- OPEN button
- STOP button
OPEN / STOP / CLOSE buttons
(4-lead solution)
- CLOSE button
- OPEN button
- STOP button

EN
CS 300 RM Gate Controls / Rev. B 1.0 – 9

10 – CS 300 RM Gate Controls / Rev. B 1.0
6.1 Overview of the LED module
Key:
LED off
LED illuminated
LED ashing
6. Programming with the LED module
6.2 Operating modes of the LED module
With the LED module, the control unit has two modes of operation:
1. AUTOMATIC
2. ADJUSTMENT
Information:
The current mode of operation of the control unit is shown via the LEDs.
- In AUTOMATIC mode, no LEDs ash. The (+) and (-) buttons have no function.
- In the ADJUSTMENT mode, at least one LED ashes. The external buttons have no function.
Pressing the (P) button toggles between the modes of operation.
Operating mode 1: AUTOMATIC
In the AUTOMATIC operating mode the door system is operated automatically.
LED displays:
H1 H2 Status
The door is open. The OPEN limit switch has been reached.
The door is closed. The CLOSED limit switch has been reached.
The door is between end positions. No limit switch has been reached.
The OPEN and CLOSE limit switches have been interrupted
(illogical state = TERM SWITCH FAIL).
Table of contents
Other MFZ Ovitor Gate Opener manuals