Mark BEAM SPOT User manual

Rev. 13.12.10
BEAM SPOT
User Manual / Instrucciones de Usuario

Thank you for choose this BEAM SPOT products, this model is the moving head light which is
the latest development of the smart, efficient products, beautiful shape, smooth R & D, combined
with the advanced techn ology of today's stage lighting products with international advanced
electronic control technology and excellent user-friendly industrial design , fully comply with CE
standard, accepted international standard DMX512 signal mode.
This moving head lights, use ceramic luminescent film reflector as a conden ser system, coupled
with the high-quality optical lens components, broadband voltage, a clear pattern, sharp and
uniform output light efficiency. Intelligent LED display module, the English language selection
mode, intuitive operating menu, shortcut.
This Beam spot, have 16/17/25 international standard DMX512 channels optional Horizontal scan:
540°ve rtical scanning 270° (16bit precision scanning) electronic correction, dot-matrix display,
four touch switch LED + single-Key flying shuttle can spin. The can be inverted 180°, the color
wheel is combined with white and 17 colors. Gobo wheel: 9 patterns + white effect round by3
facet prism and atomization function. 0-100% mechan ical dimmer, support mechanical strobe and
variable strobe effect, strobe macro function. The optical system of the lens group electric
focusing, the beam angle of 2.7 to 48° with overheating protection function.
This Moving head lights are widely used in television, disco, dance halls, nightclubs, large-scale
performances and other professional venues
manufacturer as soon as
possible.
STATEMENT
The product is good packing when ship out the factory. All users should strictly abide by the warnings and
nstructions stated in this manual, any damage and results due to misuse and the neglect of this operating
manual will be excluded from the deal responsibility this manual will not informed in additionally if have
technical changes.
PRODUCTION DESCRIPTION
1. PRODUCT INTRODUCTION
Size:320(L)×400(W)×580(H)mm
Net Weight:18KG
2. SAFETY INFORMATION
This product is only suitable for professional use, and does not apply to security for other purposes.
After you got the lights, please check the package whether have any damage caused by transportation.
If there is any damage, do not use this fixture, and please contact the dealer or
BEAM SPOT User Manual/Manual de uso Page 1
EN

Ta =40
This product is only suitable for indoor, IP20 protection class. Lamps should be kept dry to avoid
Moisture, overheating or dusty environment. Prevent lamps come into contact with water or any
other liquid.
The use of this product should pay attention to: fire, heat, electric shock, ultraviolet radiation, the
lamp to explode or
Shedding caused serious or fatal injury.
Need to read the instructions before use energized or installing.
Follow through the operation of security methods and pay attention to the warning signs on the
specification and equipment. If you have any problem for how to safely operate the equipment.
Please contact your dealer.
Please don't use the equipment if the temperature above 40º C
The lens should be changed if had damaged or any problems. Don't change the
non-original manufacturer lens.
Len size:¢1136×60 mm
Please don't move the package by one person only.
When Hang the fixture, please must verify that the facilities to be able to withstand the weight
of the lamps at least 10 times more.
Please make sure the Mounting hardware is strong enough no any damage, and insurance
for the safety rope as auxiliary security fixed in other facilities will need to verify before
installation. Installing or removing the equipment, to make the pulley below the work location.
Prohibit straight viewpoint with exposed bulbs to avoid UV damage to the eyes;
Do not use the equipment without the lens screen and the lid;
2.1 ANTI-HIGH TEMPERATURE
2.2 BURST PREVENTION
2.3 TO PREVENT FALLING WOUNDING
2.4 UV PROTECTION AND THE BULB EXPLOSION
BEAM SPOT User Manual/Manual de uso Page 2
EN

3. PACKAGE
ACCESSORY
CONTENT QUANTITY
1
HANG FIXTURE 2
SIGNAL CABLE 1
The lens and the light head covers should be timely replaced if any damage to rupture
The Fixture should be used with the protection screen together.
The electrical connection must only be carried out with corresponding qualifications;
Before installing, make sure you use the power voltage lamps must comply with the identified
power, voltage and have an overload or leakage protection;
Each lamp must be properly grounded, installed in accordance with the relevant standards;
Cut off the power when stall or replace the lamp and the fuse;
Prohibit the use of a lightning storm or wet environment.
1. Do not short-circuit temperature protection switch or fuse, use the specified type of fuse.
2. The equipment must be installed away from inflammable and explosive materials.
3. The equipment should be projected range of 3 meters away objects and projectiles
temperature less than 60 ° C; ---- 3.0m.
4. Fan or ventilation, at least in the range of 0.5 meters can not be an obstacle.
5. Do not place any object on the lens.
6. Handling at least allow the device to cool for 20 minutes.
7. Do not replace the non-original parts.
2.5 PREVENTION OF ELECTRIC SHOCK
2.6 TO PREVENT BURNING OR FIRE
3.1 ATTACHMENT
USER MANUAL
BEAM SPOT User Manual/Manual de uso Page 3
EN

PACAKGE SIZE
FLY-CASE 2 IN1 810*470*910
1. Before packed, make sure power is off, and wait for at least 20mins for cooling down.
2. Before clean the fixture, make sure X,Y axis protect lock closed.
3. After packed by plastic bag, high-lift the fixture with two handles besides the product. put
the product into the fly-case up-side-down.
4. After packed the product, put the accessory into the accessory case, then closed and lock the
fly-case.
5. Fly-case only up stacked two layers. Prohibited upside down
In order to protect the light, there is a protect lock; During the transport , the lock will closed
keeping the item in safety state.
Note: Before unpacking check the damage is whether due to the transportation or not, if
you find any such damage, please do not use this item, and contact with the dealer
or manufacturer as soon as possible.
1. Open the fly-case, and discover the inside plastic bag.
2. High-lift the product by two handles beside the bottom base and move it out.
3. Before power on, make sure you have opened the X, Y axis lock!
BEAM SPOT can be placed on the stage, or mounted in an arbitrary direction of the truss.
Two fast locks system could fix the item easily
1. Before installation must verify the fast lock is keep in good state, and can withstand at least
10 times the weight of product. Verify that the truss can withstand at least 10 times of the
total weight of the product and accessory equipments.
2. Fix the hang fixture into the hole, which located on the base of the price.
Seize handle of fasteners, clockwise rotate 1/4 turn and lock. Installed other one fastener
in the same method.
3. Using the safety cable which can withstand 10 times the weight of the equipment.
4. INSTALL STANDARD
3.2 TRANSPORT PROTECT LOCK
3.3 ABOUT PACK STAGE
3.4 UNPACKING
4.1 INSTALL LOCK
4.2 EQUIPMENT FIXED
BEAM SPOT User Manual/Manual de uso Page 4
EN

as following:
5. ALTERNATING CURRENT POWER SUPPLY
Input Voltage Total Power Frequency
110~240V 400W 50/60Hz
Fuse voltage Electronic current Specification
250V 6A 5×20
in the same method.
3. Using the safety cable which can withstand 10 times the weight of the equipment.
4. Make sure the X,Y protect locks are opened, Verify that within 3 meters there is no
combustibles .
WARNING
Fixture must use two fixing devices, and make sure the fixing device have locked! And only
fully clockwise rotate 90 ° can lock the hang fixture! Do remember plus a safety rope, and do
not connect the safety rope to plastic handle. It should be connect to the hole on the base!
Attention! One product only can accept one input one output.
BEAM SPOT DMX cable include 3 contact pins:
Pin 1, FOR GROUND; Pin 2 connected to the negative polarity signal; The pin 3
connected to the positive polarity signal.
DMX512 cable must use the professional shielded twisted pair cable; standard
loudspeaker cable is not reliable to control the long-range data.
Attention! Do not overload the connection. One continuous connection can only connect
up to 32 devices.
If use the DMX512 splitter. At first connect DMX512 Splitter input terminal to controller.
And then connected from the splitter output terminal to next device.
Do as above guide to connect other device, and finally coupled with terminal insertion
4.3 FIXTURE CONNECT
5.1 VOLTAGE, POWER, FUSE SPECIFICATION
BEAM SPOT User Manual/Manual de uso Page 5
EN

3. Loose the screws for the fan take off the stand for the fan.
4.Press the lamp reflector slightly use one finger, and press the lamp bottom
slightly use another finger. So the lamp will loose from the stand.
5.Pull out the wires for the lamp
6.Install the Lamp
The equipment must be operated by professionals; Make sure that the voltage of
power supply must be comply with the voltage identified on the lamp, and must have
an overload or leakage electrical protection.
ATTENTION!
Factory has equipped the standard 3 pin plug socket. Connect the power supply as
below table.
If lamp cable is damaged, replacement should be operate by factory or qualified
staff. Any question, please contact professionals or talk toa qualified electrician.
Live wire(L) Null(N) Ground wire
RED BLUE Yellow +Green
6. LAMP
LAMP MODEL POWER OF LAMP LIFE/HOUR COLOR TEMPERATURE
OSRAM HRI 280 280W 2200 HOURS 8000K
WARNING! There isa safety hazard or damage if install similar bulb
To reduce the risk of damage to light ,do change the lamp before using
time over 125% of lamp life.
Attention! When replace the lamp is forbidden to touch lamp with bare hand, to
avoid the greasy dirt stains filament. filament must be kept clean
1. Disconnect the power. Before replace lamp, fixture need 20 minutes for lamp
cooling. Fasten the head with Y axis protect lock in 60 ° position.
2. Use cross screwdriver to open the light body cover, remove the fan bracket,
pull out the bulb cable
6.2 LAMP REPLACE
6.1 LAMP DESCRIPTION
5.2 POWER PROTECT
BEAM SPOT User Manual/Manual de uso Page 6
EN

A001 DMX:001
ON PAN reverse On
OFF Pan reverse Off
Rtil Tilt Reverse Press UP into Tilt reverse, E key select up/down to
confirm on/off and save OK.
ON Tilt Reverse On
OFF Tilt Reverse Off
Press E into DMX address set, , UP and
DOWN key to select address number, E for
save.
Rpan Pan Reverse Press UP into Pan reverse, E key confirm up
and down, E key save OK...........................
7. CONTROL PANEL
POWER SIGNAL
LIGHT
DMX SIGNAL
LIGHT
DISPLAY SCREEN
BUTTON
7.1 CONTROL PANEL INTRODUCTION
8.1. DMX ADDRESS AND X, Y AXIS CONTROL
8. BEAM 201 CONTROL
BEAM SPOT User Manual/Manual de uso Page 7
EN

M ODE Press Up into mode Control,E key
select up/down to choose on/off and
save OK
DMX dmx mode
DIS1:16CH
DIS2:17CH
DIS3:25CH
AUTO Auto Run
SOUD Sound Active
DISPLAY MODE Press UP into Mode, E key select
up/down to choose on/off and save OK
MOD1:Normal display
MOD2:slightly bright display
MOD3:Display(any key to recover
Display Reverse
LAMP ON press E key, lamp on by manual, Display OK?
Blinking andpressE key againandsetlampon
OFF press E key, lamp off by manual, Display OK?
Blinking and press E key again and set lamp off
8.2 MODE CONTROL
8.3 DISPLAY MODE
8.4 LAMP MODE
BEAM SPOT User Manual/Manual de uso Page 8
EN

RE ST Reset
All Channels Reset Press E key , Whole unit
Reset
OPTO Expand
ON Press E key
OFF Press E key
16 CH (dmx-2 mode)DMX Value Description
CH01:Color 000-004 Color1
005-009 Color1+Color2
010-014 Color2
015-019 Color2+Color3
020-024 Color3
025-029 Color3+Color4
030-034 Color4
035-039 Color4+Color5
040-044 Color5
045-049 Color5+Color6
050-054 Color6
055-059 Color6+Color7
060-064 Color7
065-069 Color7+Color8
8.5 REST: RESET MODE
8.6 OPTO: OPTICAL COUPLE MODE
8.7 CHANNEL CONTROL
BEAM SPOT User Manual/Manual de uso Page 9
EN
Table of contents
Languages:
Other Mark Floodlight manuals

Mark
Mark LX 50G PRO User manual

Mark
Mark MAM 120 TROLLEY User manual

Mark
Mark SPACE 108 User manual

Mark
Mark MBAR 612 BAT WI User manual

Mark
Mark LX 100 RGB User manual

Mark
Mark SUPERPARLED 336 S User manual

Mark
Mark Superparled Eco User manual

Mark
Mark MBAR 120 User manual

Mark
Mark SUPERBAT LED WI 712 User manual

Mark
Mark Asym User manual