Luraco iRobotics 6 User manual

1

2
IMPORTANT SAFETY INSTRUCTIONS
When using an electrical appliance, basic precautions should always be followed, including the following:
Read all instructions before using (this appliance).
WARNING – To reduce the risk of burns, fire, electric shock, or injury to persons:
1. The main power switch is marked with international symbols “O” and “I”. The switch in position “I” means that
system is turned on, and The switch in position “O” means that system is off.
2. An appliance should never be left unattended when plugged in. Unplug from outlet when not in use and before
putting on or taking off parts.
3. Close supervision is necessary when this appliance is used by, on, or near children, invalids, or disabled
persons. Keep children away from extended foot support (or other similar parts*).
4. Use this appliance only for its intended use as described in this manual. Do not use attachments not
recommended by the manufacturer.
5. Never operate this appliance if it has a damaged cord or plug, if it is not working properly, if it has been dropped
or damaged, or dropped into water. Return the appliance to a service center for examination and repair.
6. Keep the cord away from heated surfaces.
7. Do not use outdoors.
8. Do not operate where aerosol (spray) products are being used or where oxygen is being administered.
9. To disconnect, turn all controls to the off position, then remove plug from outlet.
10. Connect this appliance to a properly grounded outlet only. See Grounding Instructions.
11. Do not remove the back cushion and do not play with roller mechanism.
12. Do not remove the bottom seat and do not play with actuators.
13. Keep the cord out of heavy traffic area. To avoid fire hazard NEVER put the cord under rugs, near heat
generating devices.
14. Always unplug the power cord from the electrical outlet immediately after use and before cleaning.
15. Always check the volume before using the headphone.
16. Do not operate any equipment with damaged parts.
17. Any other use not recommended by the manufacturer may cause electrical shock or injury to persons.
18. Do not touch or re-wire the wires connected to the master-box.
19. Do not attempt to repair or adjust any electrical or mechanical functions on this unit. Doing so will void the
warranty.
After reading this owner’s guide, if you have any questions or comments, please call +1-817-633-1080 or contact our
technical support department at [email protected] or visit our website at www.luraco.com for more information
GROUNDING INSTRUCTIONS
This product must be grounded. If it should malfunction or breakdown, grounding provides a path of least resistance for
electric current to reduce the risk of electric shock. This product is equipped with a cord having an equipment-grounding
conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and
grounded in accordance with all local codes and ordinances.
DANGER - Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with
a qualified electrician or serviceman if you are in doubt as to whether the product is properly grounded. Do not modify
the plug provided with the product - if it will not fit the outlet; have a proper outlet installed by a qualified electrician.
Followed by either instruction 1. or 2. below:
1. This product is for use on a nominal 120V circuit, and has a grounding plug that looks like the plug illustrated in
sketch A in the Fig. 1 below. A temporary adapter that looks like the adapter illustrated in sketches B and C may be
used to connect this plug to a 2-pole receptacle as shown in sketch B if a properly grounded outlet is not available.
The temporary adapter should be used only until a properly grounded outlet (sketch A) can be installed by a
qualified electrician. The green colored rigid ear, lug, or the like extending from the adapter must be connected to a
permanent ground such as a properly grounded outlet box cover. Whenever the adapter is used, it must be held in
place by a metal screw.
2. This product is for use on a nominal 120V circuit, and has a grounding plug that looks like the plug illustrated in
sketch A in the Figure below. Make sure that the product is connected to an outlet having the same configuration as
the plug. No adapter should be used with this product.

3
Fig. 1: Grounding
MEDICAL WARNINGS
Not recommended for the following people
•Patients with serious hyperostosis
•Swollen lump and patient thrombosis
•Patients with serious heart conditions
•Pregnant Women
•People that consume large amounts of alcohol
•People with diabetes
•People suffering from high fever
•Patients with malignant tumors or malignant abscesses
•People with distorted joints
•People with serious skin conditions
•People with spinal injuries
•All people should consult a physician and exercise care when operating this system
•Minors under 16 years or people unable to control his/her behavior, i.e. mental patients, people with paralysis, etc.
should not be allowed to operate the massage chair.
Do Not
•Do not use any massage function on the head
•Do not massage abdominal area or knee cap region
•Do not allow children to play near the chair especially during operation
•Do not leave mobility impaired or speech impaired people alone in chair
Additional Safety Precautions
•Do not use more than 20 minutes per session
•Do not place or stock this machine near damp places such as swimming pools or bathrooms
•Do not press by force on the massage rollers
•Do not stand on the chair or store heavy items on the chair
•Do not use in the environment which is dusty, greasy or lacking oxygen
•Do not place near steam oven, open fire, or heat
•Wear suitable clothing, do not massage with bare skin
•Do not place directly in the sun
•Do not use electric blanket while using the massage chair
•Do not use outdoors
•Do not use while smoking
•Place this machine horizontally with space over 80cm, enough for full recline mode. Place on level floor.
Do not operate near young children Do not move the machine during operation

4
NOTE: Do not use this apparatus as a bed or fall asleep in the course of massage. Do not use more than 20 minutes with
recommended 15 minutes. Prolonged massaging may cause aches, muscle or nerve issues. (The preferred total duration of
massaging within the day should be 30 minutes total or less).
Caution for User
•This device should not be used until grounded
•For a softer massage, a dry towel can be placed on the chair (never use an electric blanket,) (note that a gentle
massage pad is included)
•In the course of normal use, lift the back cushion regularly to check if there is any damage or crack in the fabric of
cushion part. Please stop using immediately even if there is minor damage, turn off the power cable. Send the cushion
in for repair to avoid possible electric shock.
•Do not move the chair while in use
•Do not place heavy objects on the armrest, foot cushion or back of the chair to avoid turning over the chair or damage to
the chair
•Do not pull the fabric forcefully or stab it with sharp objects which can result in injury or damage to the chair
•Do not move the chair on wooden floor, carpet or other easily damaged flooring
•Children and pets should not be allowed to play around chair
•Please be sure that no people, pets, or other objects are behind the chair or under the legs before reclining or lowering
the leg massager
•Do not put your hands or head under the chair
•When using the massage chair, ascertain that the footrest is in the lowest position
•Do no use immediately after meals
•Do not sit on the back cushions, armrest, or legs
•Don’t use the massage chair when your body is wet or moist as it can result in electrical shock
•Do not operate with more than one person
•Don’t use when using head ornamentation as it can result in injury
•Do not stumble over electrical wires or connections
Do Not Use the Chair under the Following Conditions
•When the apparatus has been rinsed with water or fails to operate
•Power cable is damaged
•If you feel abnormal or extremely achy during the course of the massage, please stop using the massage chair
immediately and consult a doctor
•Power failure occurs
•When the massage chair malfunctions during the course of operation
•Do not touch the inner parts of the chair as this can cause damage and electrical shock
•Do not dismantle and remove inner parts, or repair the massage chair
•Do not operate during a thunderstorm
Methods of Storage
•Do not dismount the back of the chair
•Keep the massage chair free of dust
•Cover the chair with dust-free cloth to prevent dust from collecting
•Do no store in a hot, humid, damp place or in direct sunlight or heat
•Do not store in an overly cold place
Cleaning Methods
•Before cleaning unplug from electrical source to avoid shock
•Clean the cloth surface with neutral detergent or special mild detergent for cloth
•Dust can be cleaned off with a damp cloth of mild detergent and air dry
•Do not spray pesticide on device
•Specified cleaner can be used on the leather, plastic, and dried with a cloth
•DO NOT use a damp cloth on the electronic components which can cause shock and damage
•The leather covers (headrest, seat cushion, foot cushion) can be removed for cleaning

5
iRobotics 6 Installation Parts
Controller Pillow
Foot Massager
Back Cushion
Decorative Part
A
rmrest
Casing of Seat Frame
Seat Cushion
Controller Holder
Back Rest Cover
Decorative Parts
Movable Pulley

6
Massage Chair Dimensions

7
Space Requirement
INSTALLATION INSTRUCTION
Step 1: Unpack the two large packages
Take out the main body, seat frame casing, back cushion, seat cushion, pillow, controller supporter, leg massager, controller
and wireless controller of massage chair from the box carefully. In order to avoid damaging the system we suggest at least
two people to assist with assembly.
ATTENTION
Be sure no children, pet, or substance is
around chair for enough space for installation

8
Step 2: Assemble the moving wheels
Step 3: Assemble the casing of seat frame
Incline the chair main body forward to one side about 20 degrees (Fig. 3). Loosen the two screws of rubber pad at bottom of the
seat frame (Fig. 2). Remove completely screw at center. Finally align the bottom of seat frame casing with the rubber pad and
fasten the casing to the frame (Fig. 3).
Fig. 2: Use Screw driver to loosen and tighten
screws as shown.
Package 1: Main body, seat frame casing,
back cushion, pillow, controller, supporter,
foot massager.
Package 2: Left and right armrest, and left
and right seat casing.
Tool Box: This box is inside package 1. Box
with tools, user manual, DVD, power cords,
washers, and assembly handles/screws
and nuts.
Fig. 1: Three screws are on sections as indicated with red circle above.
Center
screw
Insert lock
Insert wheel
Mother
board
cover

9
Step 4: Assemble the backrest
Fix the back to the locked upright position
Step 5: Assemble the Armrests
1. Using tools provided, remove two nuts indicated in red circle (Fig. 4 and Fig. 5)
Fig. 4 Fig. 5
Fig. 3: Once loosened, add casing and then
tighten screws to casing and frame.
Lock

10
2. Align armrest to the perfect position with chair frame, and then match the couple axle between armrest and backrest. Finally,
once aligned tighten with provided tool as shown in (Fig. 6 and Fig. 7).
Fig. 6
Fig. 7
Two armrest axis
Washer and nut
Install axis in the chute, use
the hex screw and washer to
tighten with tool provided
Tighten by hand the knob
screw handle as shown in
next photo.
Other manuals for iRobotics 6
1
Table of contents
Other Luraco Massager manuals

Luraco
Luraco iRobotics 7 series User manual

Luraco
Luraco SOFY series User manual

Luraco
Luraco iROBOTICS 9 MAX Series User manual

Luraco
Luraco iROBOTICS 7 PLUS User manual

Luraco
Luraco iROBOTICS 5 User manual

Luraco
Luraco iRobotics 6 User manual

Luraco
Luraco iRobotics User manual

Luraco
Luraco LEGEND Series User manual

Luraco
Luraco iRobotics 7 series User manual

Luraco
Luraco iROBOTICS 9 Series User manual

















