LIV GXBase User manual

User’s Manual
DARE TO LIV

TABLE OF CONTENTS
FAQ
CARING FOR YOUR LIV SWISS WATCH
PAGE 3
PAGE 4
PAGE 7
PAGE 9
PAGE 14
PAGE 16
PAGE 19
PAGE 21
PAGE 22
DDC
2
User’s Manual

THE MOVEMENT
DESCRIPTION:
Made in Switzerland
Features precision Swiss Quartz Analog
Movement (RONDA powertech Caliber 515)
Powered by a battery
PERFORMANCE:
Standard battery life of 45 months
DISPLAY:
Hours-minutes-seconds
Date window
User’s Manual
SETTING THE TIME
Position of rest (watch running)I
Quick-change correction for date
- The date can also be corrected during the day-changing
phase between 10 pm and midnight.
- The date of the following day has to be set, because no
automatic date change takes place at midnight.
- Pull the crown out to position II (watch still running).
- Turn the crown clockwise until the required date appears.
II
Setting the time
- Pull the crown out to position III (watch stopped).
- Turn the crown, until the current time is displayed
(remember the 24-hour cycle).
- Push and screw down the crown back into position I.
III
PARTS OF YOUR NEW WATCH
E
B
A
C
D
Hour handA
Minute hand
B
Second hand
C
Date display
D
Crown
E
3
User’s Manual

User’s Manual
F
E
A B C
I
J
HG D
Hour handA
Minute hand
B
Second-hand subdial
C
Date display
D
Crown
E
30 minute counter to chronograph subdialF
Second hand to chronograph
G
1/10 of a second hand to chronograph subdial
H
Start/stop function
I
Reset push button
J
THE MOVEMENT
DESCRIPTION
PARTS OF YOUR NEW WATCH
Made in Switzerland
Features precision 13 Jewel Gold Plated Swiss Quartz
Movement (RONDA startech Caliber 5040.D)
Powered by a battery
PERFORMANCE:
Standard battery life of 54 months
DISPLAY & FUNCTIONS:
1/10 second
3 eyes
Chronograph
Center stop second (1/1 sec)
1/10 seconds up to 30 minutes
30 minute counter
10 hour counter
ADD and SPLIT functions
Date window
Small second
4
User’s Manual

SETTING THE TIME
SETTING THE DATE
Unscrew and pull the crown out to position III.
1
Turn the crown to set the time.
2
Push the crown back to position I and tightly
screw it back in.*
*Failure to tightly screw it back in may result in water damage.
3
Push the crown back to position I and tightly
screw it back in.
*Failure to tightly screw it back in may result in water damage.
3
Unscrew and pull the crown out once to
position II.
1
Turn the crown to set the date.
2
5
User’s Manual

CHRONOGRAPH DISPLAY
1 2
3
START STOP RESET
1 2 3
4
Unscrew crown and
pull it twice to position III.
To leave set up mode, push the crown back to position I and tightly screw it back in.*
Hold both top and bottom
buttons until the second
hand of the chronograph
does a complete turn indicating
you are in set up mode.
Use the top button to adjust
any of the chronograph hands.
Use the bottom button to switch
between the different hands.
ADJUSTING THE CHRONOGRAPH HANDS
*Failure to tightly screw it back in may result in water damage.
6
User’s Manual

User’s Manual
THE MOVEMENT
DESCRIPTION:
Made in Switzerland
Features precision 26 Jewel Swiss Automatic Movement (Sellita SW200)
Functions without a battery; powers automatically with the movement of your arms
PERFORMANCE:
Balance frequency of 28,800 vibrations per hour (4 Hz)
Power reserve of 38 hours
DISPLAY:
Hours — minutes — seconds
Date window
E
B
A
C
D
Hour handA
Minute hand
B
Second hand
C
Date display
D
Crown
E
PARTS OF YOUR NEW WATCH
7
User’s Manual

SETTING THE TIME & DATE
Unscrewed / manual winding position
II
Screwed in and flush with the caseI
Rapid date change
III
Time change
IV
Make sure that your watch is perfectly dry.
Unscrew the crown and move it to position II to manually wind the watch 20 times.
Move it to position III to set the date.
Move it to position IV to set the time.
Avoid changing the date between 8:00 pm and 4.00 am.
Once the changes are made, push the crown back in and screw it down against the case to preserve its
water-resistance.
When a mechanical self-winding watch is not worn for a certain amount of time, its power reserve (in this
case, 38 hours) is exhausted and the watch stops. To restart it, unscrew the crown to position II and wind the
movement manually by turning the crown 30- 40 times. This will give it a sufficient power reserve to function
normally.
INSTRUCTIONS:
I II III IV
POSITION
POSITION
POSITION
POSITION
8
User’s Manual

User’s Manual
THE MOVEMENT
DESCRIPTION
Made in Switzerland
Features precision Swiss Quartz Analog
Movement (RONDA xtratech Caliber Z60)
Powered by a battery
PERFORMANCE
Standard battery life of 50 months
PARTS OF YOUR NEW WATCH
DISPLAY & FUNCTIONS
3 eyes
Chronograph
Center stop second (1/1 sec)
30 minute counter
ADD and SPLIT functions
Day indicator
Date
Small second
DDC
FA C
B
E
I
J
H
GD
Hour handA
Minute hand
B
Second-hand subdial
C
Date display
D
Crown
E
Day indicator subdialF
Second hand to chrongraph
G
30 minute counter to chronograph subdial
H
Start/stop function
I
Reset push button
J
9
User’s Manual

SETTING THE TIME
In order to set the time to the exact second, the crown must be pulled out when the second hand is in position "60."
Once the hour and minute hands have been set, the crown must be pushed back into position I at the exact second.
PLEASE NOTE:
Pull out the crown to position III (the watch stops).
1
Turn the crown until you reach the correct time.
2
Push the crown back into position I.
3
Pull out the crown to position II (the watch continues to run).
1
Turn the crown counterclockwise until the correct date appears.
2
Push the crown back into position I.
3
II IIII
III
SETTING THE DATE - QUICK MODE
During the date changing phase between approx. 09:45 PM and 12:00 PM; the date must be set to the date of the
following day.
PLEASE NOTE:
A
B
A
B
*
10
User’s Manual
This manual suits for next models
6
Other LIV Watch manuals