Ledj LEDJ186 User manual

Order code: LEDJ186
UV 50W COB Flood
1 x 50W UV COB LED
User Manual
Optional
IR remote
Order ref:
LEDJ90E

www.prolight.co.uk UV 50W COB Flood User Manual
2
Safety advice
WARNING
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL
CAREFULLY BEFORE YOUR INITIAL START-UP!
• Beforeyourinitialstart-up,pleasemakesurethatthereisnodamagecausedduringtransportation.
• Shouldtherebeanydamage,consultyourdealeranddonotusetheequipment.
• Tomaintaintheequipmentingoodworkingconditionandtoensuresafeoperation,itisnecessary
fortheusertofollowthesafetyinstructionsandwarningnoteswritteninthismanual.
• Pleasenotethatdamagescausedbyusermodicationstothisequipmentarenotsubjecttowarranty.
IMPORTANT:
The manufacturer will not accept liability for any resulting damages caused by the non-observance
of this manual or any unauthorised modication to the equipment.
OPERATING DETERMINATIONS
Ifthisequipmentisoperatedinanyotherway,thanthosedescribedinthismanual,theproductmaysufferdamageand
thewarrantybecomesvoid.Incorrectoperationmayleadtodangere.g:short-circuit,burnsandelectricshocksetc.
Donotendangeryourownsafetyandthesafetyofothers!
Incorrectinstallationorusecancauseseriousdamagetopeopleand/orproperty.
• Neverletthepowercablecomeintocontactwithother
cables.Handlethepowercableandallmainsvoltage
connectionswithparticularcaution!
• Neverremovewarningorinformativelabelsfromtheunit.
• Donotopentheequipmentanddonotmodifytheunit.
• Donotconnectthisequipmenttoadimmerpack.
• Donotswitchtheequipmentonandoffinshortintervals,
asthiswillreducethesystem’slife.
• Onlyusetheequipmentindoors.
• Donotexposetoammablesources,liquidsorgases.
• Alwaysdisconnectthepowerfromthemainswhen
equipmentisnotinuseorbeforecleaning!Onlyhandle
thepower-cablebytheplug.Neverpullouttheplugby
pullingthepower-cable.
• Makesurethattheavailablevoltageisbetween
110~240V,50/60Hz.
• Makesurethatthepowercableisnevercrimpedor
damaged.Checktheequipmentandthepowercable
periodically.
• Iftheequipmentisdroppedordamaged,disconnectthe
mainspowersupplyimmediatelyandhaveaqualied
engineerinspecttheequipmentbeforeoperatingagain.
• Iftheequipmenthasbeenexposedtodrastic
temperatureuctuation(e.g.aftertransportation),
donotconnectpowerorswitchitonimmediately.
Thearisingcondensationmightdamagetheequipment.
Leavetheequipmentswitchedoffuntilithasreached
roomtemperature.
• Ifyourproductfailstofunctioncorrectly,stopuse
immediately.Packtheunitsecurely(preferablyinthe
originalpackingmaterial),andreturnittoyourProLight
dealerforservice.
• Onlyusefusesofsametypeandrating.
• Repairs,servicingandpowerconnectionmustonlybe
carriedoutbyaqualiedtechnician.THISUNITCONTAINS
NOUSERSERVICEABLEPARTS.
• WARRANTY:Oneyearfromdateofpurchase.
CAUTION!
KEEP THIS EQUIPMENT
AWAY FROM RAIN,
MOISTURE AND LIQUIDS
CAUTION!
TAKE CARE USING
THIS EQUIPMENT!
HIGH VOLTAGE-RISK
OF ELECTRIC SHOCK!!

www.prolight.co.uk UV 50W COB Flood User Manual
3
Product overview & technical specications
Thispowerful50WUVFloodwillllavarietyofvenueswithanoutstandingUVglow.Theseunitshavearugged,
metalhousingandmeasureonly130mmindepthforeasytransportationandinstallation.
Theyarealsoconvectioncooledforsilentoperationandfeaturea85°beamangle.The4pushbuttonLED
menuorincludedIRremotealloweasyaccesstothefunctionsincludingDMX,master/slave,soundactive
andstandalonemodes.
•1x50WUVCOBLED
•Beamangle:85°
•1.1kHzrefreshrate
•DMXchannels:1or2selectable
•Standalone,soundactiveandmaster/slavemodes
•0-100%dimmingwithvariablestrobe
•Bracketallowsformultipleriggingand
oorstandingapplications
•Rearcontrolpanelandrubberfeetallowthe
paneltositatontheoorforuplighting
•4pushbuttonmenuwithLEDdisplay
•SideentryXLRandpowerconnections
•IECpowerin/outsockets
•3-pinXLRin/outsockets
•Fancooled
•SuppliedwithIRremote(LEDJ90E)
UV Spectra Batten
Specications UV 50W COB Flood
Powerconsumption 56W
Powersupply 110~240V,50/60Hz
Fuse F1A250V
Dimensions 284x248x130mm
Weight 2.8kg
Ordercode LEDJ186
248mm 130mm
284mm

www.prolight.co.uk UV 50W COB Flood User Manual
4
01-Bracket
02-Brackettighteningknobs
03-Earthpoint
04-LEDdisplay
05-Functionbuttons
06-DMXinputsocket
07-DMXoutputsocket
08-IECpowerinsocket
09-IECpoweroutsocket
10-FuseF1A250V
0810 0903 07 06
ENTER DOWN
MODE
UP
POWER IN POWER OUT DMX OUT DMX IN
www.prolight.co.uk
UV
50W COB FLOOD
02
04
05
01
PUSH
Technical specications
Inthebox:1 x xture,
1 x IR remote,
1 x power cable &
1 x user manual

www.prolight.co.uk UV 50W COB Flood User Manual
5
Operating instructions
DMX channel mode:
ToaccesstheDMXchannelmode,pressthe“MODE”buttonontherearoftheunittoshowA001
ontheLEDdisplay.Nowpressthe“ENTER”buttonandusethe“UP”and“DOWN”buttonstosetthe
desiredDMXaddress.Nowpressthe“ENTER”buttontochooseoneofthe1or2DMXchannelmodes
usingthe“UP”and“DOWN”buttons,andpressthe“ENTER”usethe“UP”and“DOWN”buttonstoset
whattheunitshoulddoifitlosesDMXsignal.
bLC-TheunitwillblackoutifDMXsignalislost.
Soun-TheunitwillgointosoundactivemodeifDMXsignalislost.
HoLd-TheunitwillholdthelastDMXcommandifDMXsignalislost.
Toexitoutofanyoftheaboveoptions,pressthe“MODE”button.
Static mode:
Toaccessstaticmodepress“ENTER”untilthedisplayshowsC-00ontheLEDdisplay.
Toadjustthebrightnessusethe“UP”and“DOWN”buttonstoselectbetweenC-00~C-99.
Pressthe“ENTER”buttontoconrmthesetting.Nowusethe“UP”and“DOWN”buttonstoadjustthe
ashspeedbyselectingbetweenF-00~F-99.Pressthe“ENTER”buttontoconrmthesetting.
Toexitoutofanyoftheaboveoptions,pressthe“MODE”button.
Slave mode:
Pressthe“MODE”buttonontherearoftheunittoshowSLAUontheLEDdisplayandpressthe
“ENTER”buttontoconrmthesetting.Theunitwillnowruninsequencewiththemasterunit.
Toexitoutofanyoftheaboveoptions,pressthe“MODE”button.
PleaseensurethatallslaveunitsaresettothesameDMXchannelmodeasthemasterunit.
Sound active mode:
Toaccessthesoundactivemode,pressthe“MODE”buttonontherearoftheunittoshowSU00
ontheLEDdisplay.Nowpressthe“ENTER”buttonandusethe“UP”and“DOWN”buttonstosetthe
soundsensitivitylevelfromSU.00~SU.99andpressthe“ENTER”buttontoconrmthesetting.
Value: 00 - 99 (00 = low, 99 = high)
Toexitoutofanyoftheaboveoptions,pressthe“MODE”button.
Channel Value Function
1000-255 Masterdimmer(0-100%)
Channel Value Function
1000-255 Masterdimmer(0-100%)
2000-255 Flashspeed(slowtofast)
1 channel mode: 2 channel mode:
Staticmode C-00~C-99Brightness(0-100%)
F-00~F-99Flashspeed(slow-fast)
Slavemode SLAV
Soundactivemode SU00~SU99
Menusystem
DMXmode 1CH,2CH
Addresssetting A001~A512
IRfunction Iron -IROn
IroF -IROff

www.prolight.co.uk UV 50W COB Flood User Manual
6
Operating instructions & DMX setup
Included IR remote functions:
Button functions:
DMX address examples:
TosettheDMXaddress;
• Pressthe“S”button,theLEDxturewillilluminate
infull,youcannowstarttosettheDMXaddress
• Selecttherequired3digitDMXaddress
(eg001or136or275)theunitwillthenash
toconrmtheaddresshasbeenset
• Nowpressthe“DMXMODE”buttontosavethenewaddressintothememory
Important notes:
• SettheDMXaddressoneachxturebeforepluggingintotheDMXcontroller
• TheIRremotecannotbeusedwhenthexture(s)arebeingcontrolledwithaDMXcontroller
• ThemaximumIRtransmitterdistanceis10m-PleasemakesurethatyouhavetheIRremote
aimeddirectlyatthefrontpanelofeachxturetobeprogrammed
• Ifyoudonotpressthe“DMXMODE”buttonafteryouhavechangedtheDMXaddresswhenyou
powerdownthextureitwilllosetheaddressyouhaveset
Setting the DMX address:
TheDMXmodeenablestheuseofauniversalDMXcontroller.Eachxturerequiresa“startaddress”
from1-512.Axturerequiringoneormorechannelsforcontrolbeginstoreadthedataonthechannel
indicatedbythestartaddress.Forexample,axturethatoccupiesoruses7channelsofDMXandwas
addressedtostartonDMXchannel100,wouldreaddatafromchannels:100,101,102,103,104,105
and106.Chooseastartaddresssothatthechannelsuseddonotoverlap.E.g.thenextunitinthe
chainstartsat107.
01-Blackout
02-TosetthebrightnessoftheLEDeither
select20%,50%or100%oralternatively
youcanusethe‘+’and‘-’buttons
03-Flashoff
04-TosettheashspeedoftheLEDeither
select20%,50%or100%oralternatively
youcanusethe‘+’and‘-’buttons
05-SetstheLEDxtureintoDMXmode
06-SetstheLEDxtureintosoundactivemode
07-SetstheLEDxtureintoslavemode
08-SetstheDMXaddressfortheLEDxture
1 2 3
4 5 6 0
+
_
7 8 9
D SL S
OFF 20% 50% 100%
SA
STROBE
OFF 20% 50% 100%
DIMMING
SLAVE SET ADDRSOUND ACTIVEDMX MODE
01
04
02
07
06
05 08
Included
IR remote
Order code:
LEDJ90E
03

www.prolight.co.uk UV 50W COB Flood User Manual
7
DMX 512:
DMX(DigitalMultiplex)isauniversalprotocolusedasaformofcommunicationbetweenintelligent
xturesandcontrollers.ADMXcontrollersendsDMXdatainstructionsformthecontrollertothexture.
DMXdataissentasserialdatathattravelsfromxturetoxtureviatheDATA“IN”andDATA“OUT”
XLRterminalslocatedonallDMXxtures(mostcontrollersonlyhaveadata“out”terminal).
DMX linking:
DMXisalanguageallowingallmakesandmodelsofdifferentmanufacturestobelinkedtogether
andoperatefromasinglecontroller,aslongasallxturesandthecontrollerareDMXcompliant.
ToensureproperDMXdatatransmission,whenusingseveralDMXxturestrytousetheshortest
cablepathpossible.TheorderinwhichxturesareconnectedinaDMXlinedoesnotinuencethe
DMXaddressing.Forexample;axtureassignedtoaDMXaddressof1maybeplacedanywherein
aDMXline,atthebeginning,attheend,oranywhereinthemiddle.Whenaxtureisassigneda
DMXaddressof1,theDMXcontrollerknowstosendDATAassignedtoaddress1tothatunit,
nomatterwhereitislocatedintheDMXchain.
DATA cable (DMX cable) requirements (for DMX operation):
ThisxturecanbecontrolledviaDMX-512protocol.TheDMXaddressissetonthebackoftheunit.
YourunitandyourDMXcontrollerrequireastandard3-pinXLRconnectorfordatainput/output,
seeimagebelow.
Also remember that DMX cable must be daisy chained and cannot be split.
Notice:
Besuretofollowthediagramsbelowwhenmakingyourowncables.Donotconnectthecables
shieldconductortothegroundlugorallowtheshieldconductortocomeincontactwiththeXLRs
outercasing.Groundingtheshieldcouldcauseashortcircuitanderraticbehaviour.
DMX setup
FurtherDMXcablescanbe
purchasedfromallgoodsound
andlightingsuppliersor
ProLightConceptsdealers.
Pleasequote:
CABL10 – 2m
CABL11 – 5m
CABL12 – 10m

www.prolight.co.uk UV 50W COB Flood User Manual
8
Special note:
Line termination:
Whenlongerrunsofcableareused,
youmayneedtouseaterminatoron
thelastunittoavoiderraticbehaviour.
Using a cable terminator will decrease
the possibilities of erratic behaviour.
(3-pin - Order ref: CABL9O, 5-pin - Order ref: CABL89)
5-pin XLR DMX connectors:
Somemanufacturesuse5-pinXLRconnectorsfordatatransmissioninplaceof3-pin.5-pinXLRxtures
maybeimplementedina3-pinXLRDMXline.Wheninsertingstandard5-pinXLRconnectorsintoa
3-pinlineacableadaptormustbeused.Thediagrambelowdetailsthecorrectcableconversion.
Terminationreducessignaltransmission
problemsandinterferance.itisalways
advisabletoconnectaDMXterminal,
(resistance120Ohm1/4W)betweenpin2
(DMX-)andpin3(DMX+)ofthelastxture.
5-pin XLR (socket)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
Pin 4: N/C
Pin 5: N/C
3-pin XLR (socket)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
3-pin XLR (socket)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
5-pin XLR (socket)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
Pin 4: N/C
Pin 5: N/C
DMX setup & WEEE notice
Correct Disposal of this Product
(Waste Electrical & Electronic Equipment)
(Applicable in the European Union and other European countries
with separate collection systems)
Thismarkingshownontheproductoritsliterature,indicatesthatitshouldnotbedisposedof
withotherhouseholdwastesattheendofitsworkinglife.Topreventpossibleharmtothe
environmentorhumanhealthfromuncontrolledwastedisposal,pleaseseparatethisfromother
typesofwastesandrecycleitresponsiblytopromotethesustainablereuseofmaterialresources.
Householdusersshouldcontacteithertheretailerwheretheypurchasedthisproduct,ortheir
localgovernmentofce,fordetailsofwhereandhowtheycantakethisitemforenvironmentally
saferecycling.
Businessusersshouldcontacttheirsupplierandcheckthetermsandconditionsofthe
purchasecontract.Thisproductshouldnotbemixedwithothercommercialwastesfordisposal.
This manual suits for next models
1
Table of contents
Other Ledj Light Fixture manuals
Popular Light Fixture manuals by other brands

Emos
Emos CLASSIC ZY1431T manual

Westinghouse
Westinghouse Outdoor Lighting Fixture owner's manual

Hedler
Hedler C 12 silent Operation manual

Blizzard Lighting
Blizzard Lighting Puck: CSI manual

Energetic Lighting
Energetic Lighting ELYSL-5004 Series installation instructions

Lightmaxx
Lightmaxx Shaft 5R user manual

Cooper Lighting
Cooper Lighting Halo L3232E Specification sheet

Stageline
Stageline ODW-2410RGBW instruction manual

Light Sky
Light Sky Tornado Series user manual

Lightolier
Lightolier Paralyte 2424 PLA2G9LS26U specification

Lightolier
Lightolier Lytespan 83ED17S specification

Lightolier
Lightolier Calculite CS8226 specification