“Clean Brewer” Screen Appears
Issue:
Whenusingtheunit,theCleanBrewerscreenappears.
Solution:
There are two reasons why the "Clean Brewer Screen” appears.
1.
The brewer is designed so that after a beverage is brewed the capsulelifting
mechanism returns fully to the “Home” position.A Hall Sensor is installed in
the unit to verify that the mechanism has returned Home. If themechanism
does not return to Home then the Clean Brewer screen is displayed. The
normal cause for this to occur is that there has been a beverage build up in
the chamber preventing the mechanism to fully return to Home. Follow the
cleaning instructions to clean the brewer.
2.
ThesecondreasontheCleanBrewerscreenwillappearisduetoafaultyHall
Sensor or faulty connection. Remove the lid of the unit. Locate the main PCB
undertheblack plastic shieldon thefront right ofthe unit. On the far left of the
mainPCBlocatetheblackconnectorattached tothe ribboncable. Ensure the
black connectorisproperly seated ontothemainPCB. Remove, reinstall, and
ensure the two locks are secure. If that does not resolve the issue,follow the
ribbon lead going to the back bottom of the brewer. Locate the secondary
connection to the Hall Sensor. Ensure that the secondary connection is
properlyseated.Ifthatdoesnotresolvethe issuethenreplace theHomeHall
Sensorlocatedinthebrewergearbox.
ALWAYS-ChecktheconnectionsontheMainPCB.Ensuretheblackribbonconnectorwith
the grey wires are properlysnapped in place. It is a good practice is to remove and reset
this connection, ensuring the side clips are properly snapped inplace