LAIA Cute Thermal User manual

Copyright © 2020 Laia · www.laiatech.com All rights reserved
Contents
OVERVIEW .............................................................................................. 2
SPECIFICATIONS ........................................................................................ 3
CONNECTION MODE ................................................................................... 4
BACKGROUND SOFTWARE ............................................................................. 5
4.1 INTERFACE....................................................................................... 5
4.2 DRIVER INSTALLATION ............................................................................ 5
4.3 SOFTWARE APPLICATION .......................................................................... 9
4.3.1 Real-time image..................................................................... 9
4.3.2 Temp measurement .............................................................. 11
4.3.3 Zone temp measurement ........................................................ 12
4.3.4 Color palette ...................................................................... 12
4.3.5 Alarm .............................................................................. 13
4.3.6 Snapshot .......................................................................... 13
4.4 TEMP MEASUREMENT .......................................................................... 13
4.4.1 Distance ........................................................................... 13
4.4.2 Calibration......................................................................... 14
4.4.2.1 No blackbody mode................................................. 14
4.4.2.2 Blackbody mode .................................................... 14
DEPLOYMENT PRECAUTIONS ........................................................................ 15

Copyright © 2020 Laia · www.laiatech.com All rights reserved
Overview
CUTE THERMAL is a high-precision thermal imaging, which can measure the temp of target
object online in real time, output thermal image video and check the over-temp condition. Going
with different matching platform software, it can be suitable for different usage modes (such as
power device temp measurement, fire alarm, human body temp measurement and screening).
This document only introduces the usage modes for human body temp measurement and
screening.
CUTE THERMAL employs USB supply power and transmit data are completed through one
USB line, realizing convenient and rapid deployment.
Based on on-site deployment of clients, CUTE THERMAL can carry out temp compensation
varying with environment changes voluntarily without continuous blackbody calibration and
control the error within the range of ±0.6°C (±1.08°F).

Copyright © 2020 Laia · www.laiatech.com All rights reserved
Specifications
CUTE THERMAL specifications are as follows:
Parameters Index
Infrared
thermal
imaging
Resolution 320x240
Response wave band
8-14um
Frame rate 9Hz
NETD 70mK@25°C (77°F)
Field angle 34.4 in horizontal, 25.8 in vertical
Lens 6.5mm
Measurement range -10°C - 300°C (14°C-572°C)
Measurement
accuracy
For human body, the temp compensation algorithm can reach
±0.6°C (±1.08°F)
Measurement Temp measuring area and center point can be set
Color palette Whitehot, Rainbow, Iron, Tyrian.
General
Interface
Power supply and data transmission through standard Micro USB
2.0
Language English
Operating temp
-20°C (-4°F) ~ +60°C (+140°F) (for the requirement of accurate temp
measurement of human body, it is recommended to use at ambient
temp of 10°C (50°F) ~ 30°C (+86°C))
Storage temp -40°C (-40°F)- +85°C (+185°F)
Waterproof and
dustproof IP54
Size 129mm*73mm*61mm (L*W*H)
Net weight 295g
Picture storage BMP, JPG.
Installation Standard tripod or pan-tilt hoisting is adopted.
Software
Temp display
High temp tracking in measurement area can be set, and fixed-point
measurement of center temp can be carried out
Alarm
Available for alarm over the set threshold temp (high and low
temp), can sound alarm, snapshot alarm photos and store
simultaneously.
Frame temp
measurement
Temp measurement is set according to different entry and exit
personnel channels
Temp compensation
The staff can set up temp compensation according to the
environments
Photograph Manually under opening, automatically under alarming
Internet cloud
upload Customized according to cloud requirements

Copyright © 2020 Laia · www.laiatech.com All rights reserved
Background software
3.1 Interface
This system only available for Win10 OS, and the background software interface is as follows:
3.2 Driver installation
After connecting the computer to the CUTE THERMAL camera with Micro USB 2.0 cable, open the
"Device Manager", and locate the "Universal Serial Bus devices" or “other devices” or "PIR324
Thermal Camera" with exclamation mark in "USB"

Copyright © 2020 Laia · www.laiatech.com All rights reserved
Double click and click "Update Driver", browse and find the driver directory. The exclamation
mark disappears after installation completed
Double click "DYTiRViewer.exe" to operate the software.
Please refer to the following steps, if you are prompted that the driver cannot be installed due to
driver hash value:
Open the "Settings" and click “Update and Security”:

Copyright © 2020 Laia · www.laiatech.com All rights reserved
3.3 Software application
Double click DYTirViewer.exe to run the program. If the program cannot be run after the driver
installation is completed, please confirm whether the last supported "Microsoft VC++
Redistributable" has been installed. If not, please search and download the corresponding version
online, and the program will run normally after installation.
3.3.1 Real-time image
Select the camera in red box in the figure below, click the "Play", and the current image of the
camera will be displayed on the right. Click "Stop" to stop displaying the real-time image. Click
"Photo" to select "Folder" and save the image.
Table of contents
Popular Laboratory Equipment manuals by other brands

Agilent Technologies
Agilent Technologies 5800 ICP-OES user guide

Endress+Hauser
Endress+Hauser Cleanfit CPA875 operating instructions

NI
NI PXI-5422 CALIBRATION PROCEDURE

Collomix
Collomix Aqix operating instructions

SPEX SamplePrep
SPEX SamplePrep 6875 Freezer/Mill Series operating manual

Ocean Insight
Ocean Insight FLAME-NIR+ Installation and operation manual

Parker
Parker ALIGN-MG-NA Installation, operation and maintenance manual

BD
BD 644787 user guide

DENTAURUM
DENTAURUM Compact Megaplus Instructions for use

Biuged Laboratory Instruments
Biuged Laboratory Instruments BGD 626 instruction manual

VWR
VWR SAS Super IAQ instruction manual

illumina
illumina MiSeqDx reference guide









