Kengo PUSXBS User manual

Luen Yick Electrical Mfg. Co., Ltd.
Flat F, 10/F., Block 2, Kingsford Ind. Building 26-32 Kwai Hei Street, Kwai Chung, N.T. Hong Kong ILL500A
Pack Contents:
Pop-up socket x 1
Fixing pack x 1
Instruction leaflet x 1
PUSXBS
PUSXBS-2C
PUSXBS-2U
PUSXBS-2C2U
PUSXBS-BA2C
PUSXBS-BA2U
X=no.of socket - Max.3
PUS1BS-BA2C2U
DUSXBS
DUSXBS-2C
DUSXBS-2U
DUSXBS-2C2U
DUSXBS-BA2C
DUSXBS-BA2U
X=no.of socket - Max.3
DUS1BS-BA2C2U
PLEASE READ THESE BEFORE COMMENCING INSTALLATION AND
RETAIN FOR FUTURE REFERENCE.
If the external flexible cable or cord of this socket is damage, it shall
be exclusively replaced by the manufacturer or his service agent or similar
qualified person in order to avoid a hazard.
This is a Class I product. Must earth.
CAUTION: Risk of Electric Shock - For indoor use only
If in doubt regarding these installations, consult a qualified electrician.
Product:
INSTALLATION INSTRUCTION
Pop-up Socket
IP54
CAUTION : It is not applicable for the digital products with internal
protection or the ones requiring driving programme
Output Current : Max. 2100mA
Individual switch for power on / off
LED indicator function when power on
USB CHARGER SPECIFICATION
According to Waste of Electrical and Electronic Equipment (WEEE) directive, WEEE should be separately collected and treated. If at any
time in future you need to dispose of this product please do not dispose of this product with household waste. Please send this product to
WEEE collecting points where available. Do not dispose this product as unsorted municipal waste. Collection of such waste separately for
230-250V~50Hz
Max. 3250W 13A
Specification
MAINTENANCE
Ensure that to disconnect the power prior to cleaning.
To keep the finish of this product, wipe over with soft cloth periodically.
Clean the socket with a damp cloth and mild detergent, dry immediately.
Do not use harsh chemical solvents, it may dis-color or damage the finish.
Never force to life up or push down – always check that there are no obstructions that could
interfere during retraction.
Output Voltage : 5V DC
Output Power : Max. 2W
Sensitivity : L/R 380MV
SNR : >80db
Speaker Frequency Range : 280Hz-16KHz
MINIATURE AUDIO SPEAKER SPECIFICATION
Audio Connector : Standard 3.5mm headphone connector
- Suitable for all music player, include MP3, MP4, Smartphones, iPhone 5, iPad, Android Phones.
Bluetooth
How to Connect to Bluetooth
- Switch on the power, you will see the bluetooth signal indicator start flashing.
- Open your mobile device and turn on the bluetooth function, connect the device named “Kengo” or
“Kengo0001” (note: if the name showing Kengo0001 it means the number digit would be different.)
- Then press connect to the device, if the connection ok, then you will hear a “bip” sound and the
bluetooth signal indicator flashing a different frequency.
- Onced connected, you can start play the music now.
Audio
connector
Volume &
ON/OFF
Power
Indicator
Bluetooth
Signal
Indicator
RJ45 8-connector, category 5 standard
Contacts are phosphor bronze plated with hard gold.
Superior performance and low loss signal transmission.
For cable extension use only, please make sure the extend cable is
connected to suitable data socket before use.
RJ45 DATA SOCKET SPECIFICATION

Luen Yick Electrical Mfg. Co., Ltd.
Flat F, 10/F, Blk 2, Kingsford Ind Bldg, 26-32 Kwai Hei St, Kwai Chung, N.T., Hong Kong
OPERATION
ATTENTION:
Only use the silver handle to lift the unit.
ATTENTION:
IP54 is only available when remove all plugs from socket
and in closed position.
1
2
Swivel up lifting handle
and pull up socket
When choosing location, select a surface
between 10mm and 50mm thick.
INSTALLATION
ATTENTION: Ensure there is sufficient space
under the installed surface, for the unit when it
retracts to the closed position.
Cut out 92 mm diameter hole in work surface.
Allow minimum 25mm clearance surround the
cut hole.
The locking ring with rubber washer is supplied in
the packaging. If attached to the mounting collar,
remove it by rotating it in an anti-clockwise direction
prior to lowering the unit into its final location.
The installation may only be carried out by an electrical specialist in accordance with international
and national standards.
Ø 92 mm
25 mm
25 mm
1
2
Insert socket into the hole.
3
Connect cable to power supply, once work has been completed
correctly, the product is now ready to use.
5
Place locking ring into collar. Identify and align arrows on
collar and locking ring to ensure the thread is engaged
properly. Turn the locking ring clockwise to tighten. Make
sure rubber washer is compressed tightly on underside of
surface. Tighten the screw until the ring firmly grip the surface.
4
To use the Pop-up Socket, gentle lift up the silver handle on the top cover until all socket
outlets are exposed and the orange stop/release button clicks and locks the unit in place.
Press the master switch on. An orange light confirms that
power is available. You can use all the power sockets.
The unit can be retracted in position by pressing the
orange stop/release button and push the unit down until
it is flush with the surface. And leaving the engaged
cables on the window of the top cover.
Press
to release
This manual suits for next models
13