Irwin Powerbase S8 User manual

Imaginative, Innovative & Inspiring
Products & Training to Education
Powerbase S8
Instructions
5 Year Warranty
www.irwinscienceeducation.com [email protected] Tel: 01376 340 506www.irwinscienceeducation.com [email protected] Tel: 01376 340 506
IrwinScienceEducationLimited,27KestrelPark,SpringwoodIndustrialEstate,Braintree,EssexC 72SF
RegisteredinEngland&Wales.Companyno.08748657
- IrwinScienceEducationherebywarrants,totheenduser("Purchaser")whopurchasedthegenuineIrwinScienceEduca-
tionproduct(“Product"),fromanauthorisedIrwinScienceEducationreseller.
(“Reseller”),thattheProductwillbefreefromdefectsinmaterialsandworkmanship("Defects"),foraperiodoffiveyears
fromthedatetheProductwaspurchasedfromIrwinScienceEducation
directorviaauthorisedreseller.Subjecttothetermsandconditionsindicatedbelow.
- IrwinScienceEducationwillrepairorreplacesuchProductorpartthereofwhich,uponinspectionbyIrwinScience
Education,isfoundtobedefective,despitetheProductnothavingbeensubjectedtoImproperActivity(definedbelow).
Improperactivityshallrenderthiswarrantyvoid.“ImproperActivity”includesanyandallofthefollowing:
InstallationbyanyoneotherthanaReseller:
Improperinstallation:
Use/operation/maintenanceotherthaninaccordancewithIrwinScienceEducation’sinstructionsandrequirementswithin
aneducational/trainingestablishment(asdirectedbelow);
TamperingbyPurchaser;neglect;damagebytheapplicationofforce;bending;breaks;cracks;scratches;anyother
actofvandalism;
RepairoralterationbyanyoneotherthanaReseller:Useofadditionalcomponentsorothercomponentsthatarenotsuit-
ableandgenuineIrwinScienceEducationcomponents;
Useinanon-educationalteachingenvironment.
- AlltheforegoingasdeterminedbyIrwinScienceEducation,initssolejudgment.
-InstructionsandrecommendationsforcorrectuseofIrwinproductsarewithintheoriginalproductinstructionsor
availablefordownloadfromwww.irwinscienceeducation.com.
-IrwinScienceEducation’ssoleobligationunderthislimitedwarrantyistorepairorreplace,atIrwinScienceEducation’s
solediscretionanyProductand/orProductcomponentfoundbyIrwinScienceEducationtohaveDefects.Thislimited
warrantydoesnotgrantanyotherrightsorgiverisetoanyotherobligation,orabsolvePurchaseroftheresponsibilityto
employanyothersuitablemeasures,bywhatevermeans,includinginsurance,againsttheriskofpersonalinjuryor
damagetoproperty.
Thislimitedwarrantyrelatestoproduct’sdefectsonly.IrwinScienceEducationshallbeliable,inanyevent,forany
labourcostsassociatedwiththeproductanditsinstallationprocess.Inordertofacilitatethewarrantyserviceand
enableIrwinScienceEducationtodetermineentitlementunderthiswarranty,Purchasermustfirsthavecompletedthe
onlineproductregistrationregistrationformwithin1monthoftheoriginalproductpurchasedate,withproofof
purchasefromaResellerviatheprintedproductregistrationcardsuppliedoronlineat
www.irwinscienceeducation.com.Allshipping,handlingorotherincidentaland/orrelatedchargesarefullypayableby
thepurchaseronlyandarenotincludedinthislimitedwarranty.Itemsexcluded/limitedfromthiswarranty,Screws,Nuts,
Bolts,Normalwearandtear,Cleaningwithcleaningdetergents,Improperhandlingandmisuse.

www.irwinscienceeducation.com [email protected] Tel: 01376 340 506www.irwinscienceeducation.com [email protected] Tel: 01376 340 506
TheIrwinPowerbaseS8isaheavy-dutypowersupplyoffering0-12Vacand0-12Vdc
outputsinapprox1Vsteps.Bothoutputsareselectedbyarotaryswitchandmaybe
usedsimultaneouslyuptoacombinedoutputcurrentof8A.
Thefrontpanelthreisaon/offswitch,fiveoutputsocketsforac,dcandearthanda
resetbutton.Theresetbuttonoperatesifthereisashortcircuitoroverloadonanyof
theoutputs.Shouldtheresetbuttonpopout,switchoffthesupply,rectifythefault,switch
onagainandpressthebuttonin.Pleasenotethatthebuttontakesabout5secondsto
resetandwillnotworkifpushedwithinthistime.
Please Note: Theoffloadvoltagesarehigherthanmarkedonthedial.
Foraccurateoutputvoltagesasuitablevoltmeterormultimetershouldbeemployed.
Turnthedialtozero,connectyourloadandthendialuptherequiredvoltage.
Theunitalsoutilisesavoltagelimitlock,whichsetsthemaximumvoltageobtainable.
Tosetthelock,proceedasfollows:
•SlackenthelimitlockwiththeAllenkeysupplied
•Setthemaximumvoltagerequiredonthedial
•Rotatetheplasticdiscanti-clockwiseuntilthestudsitsagainsttheknobpointer
•Tightenthelimitlock
PAT testing
ThepowersupplyisclassifiedasClass1.
AsuitableearthbondtestpointisthevoltagelockAllenkeybolt.
Electromagnetic Compatibility
Theuseofthisapparatusoutsidetheclassroom,laboratory,studyareaorsimilarsuchplaceinvalidates
the conformity with the protection requirements of the Electromagnetic Conformity Directive
(89/336/EEC)andcouldleadtoprosecution.
IMPORTANT - ELECTRICAL SAFETY NOTICE
Connectiontomainselectricitysupply.Thisapparatusisdesignedtosafetyclass1.Before
connectingtothemainselectricitysupply,examinetheinformationontheapparatusrating
label.Ensurethatthemainssupplyissinglephasealternatingcurrent(a.c)offrequency
50Hzat230V,withneutralnominallyatearthpotential.
WARNING - THIS APPARAT S M ST BE EARTHED
YourIrwinproductshouldcomewithaplugwiththerecommendedfuserating.However
ifnotfittedconnectthewirestoanon-reversibleUK3pinplugasfollows:
Green/Yellowwiretotheterminalmarked: E(Earth)colouredGreen/Yellow
Bluewiretoterminalmarked: N(Neutral)orcolouredBlue
Brownwiretoterminalmarked: L(Live)orcolouredBrown
LIVE PARTS SHO LD NEVER BE EXPOSED NLESS THE APPARAT S HAVE BEEN SWITCHED OFF
AND ISOLATED FROM THE MAINS ELECTRICITY.
CORRESPONDENCE:
intheeventofanycorrespondenceconcerningthisapparatus,pleasecontactyoursupplyingagent
quotingtheircataloguenumberandserialnumbershowontheapparatus.Thiswillhelpusprocessyour
enquiryquickly.Anysparepartswhichmayberequiredaresuppliedontheunderstandingthatthe
replacementofthoserequiringtheexposureofliveelectricalconnectionswillbeundertakenbyan
electricallyqualifiedperson.
Popular Laboratory Equipment manuals by other brands

Agilent Technologies
Agilent Technologies 5800 ICP-OES user guide

Endress+Hauser
Endress+Hauser Cleanfit CPA875 operating instructions

NI
NI PXI-5422 CALIBRATION PROCEDURE

Collomix
Collomix Aqix operating instructions

SPEX SamplePrep
SPEX SamplePrep 6875 Freezer/Mill Series operating manual

Ocean Insight
Ocean Insight FLAME-NIR+ Installation and operation manual

Parker
Parker ALIGN-MG-NA Installation, operation and maintenance manual

BD
BD 644787 user guide

DENTAURUM
DENTAURUM Compact Megaplus Instructions for use

Biuged Laboratory Instruments
Biuged Laboratory Instruments BGD 626 instruction manual

VWR
VWR SAS Super IAQ instruction manual

illumina
illumina MiSeqDx reference guide