Multicast streamer for IP broadband networks. Up to twenty-eight simultaneous satellite
radio programs encoded for IP streaming over IP multicast networks.
Designed and manufactured by Messrs Ikusi of Spain. Sold and supported by
Teletechnique Beechmont in Queensland.

RNS101
JFree-to-air or MultiCrypt DVB-S reception.
JCommon Interface.
JUp to 8 simultaneous IP or 28 only-Radio programmes,
with individual multicast addresses.
JFiltering of information contained in the MPEG-2 tables.
JUDP and RTP transmission protocols.
JWeb interface for module conguration.
JAlarm information SNMP agent.
JSAP and SDP protocols to facilitate automatic programme selection in the
set-top box and to provide programme information to external servers.
RNS-101
Reception
FTA or MultiCrypt
DVB-S
(Common Interface,
EN5022)
Number of simultaneous “Radio
Programme” streams delivered up to 28
Max number of de-encrypted
Radio Programmes
Variable
(CAM depending)
SNMP Support - traps Yes
DiSEqC equipped (vers. 1.08) Yes
Input Section (QPSK/8PSK)
Frequency range MHz 950 – 2150
Input level dBm -65 – -25
Input loop-through gain dB 0 (±1)
Input symbol rate MS/s 2 – 45
Output Section (IP)
Standard IEEE 802.3 10/100
BaseT
Bit rate Mbps up to 100
Transmission protocols UDP/RTP
Multicast Yes
Conectors
RF input (loop-through) (2x) female F
DC connection banana socket
CAM entrance –
Conguration RS-232/DB-9
Ethernet output RJ-45
General
Supply voltage Vdc +12
Consumption mA 310 (
without CAM
),
480 (
with CAM
)
Max DiSEqC current mA 300
Indicator leds ON - STATUS
- LINK - ACT
Operating temperature °C 0 – +45
Dimensions mm 230 x 195 x 32
Each module is packed with:
- 1 F plug bridge, 64 mm length, for input tap line.
- 1 DC plug bridge, 53 mm length, for connection of +12 voltage.
Ángel Iglesias, S.A.
Paseo Miramón, 170
20009 San Sebastián, Spain
Tel. +34 943 44 88 00
Fax +34 943 44 88 20
www.ikusi.com
— Example of a mixed SNS/RNS headend
for eight digital satellite TV transponders.
Contains 6 SNS-101 streamers, 2 RNS-101
and 1 CFP-500 power supply, all fixed on 1
BAS-900 baseplate. The headend can feed
the IP network with 48 TV programmes (8
programmes per SNS streamer) plus 56 Ra-
dio programmes (28 programmes per RNS
streamer).
RED IP
switch Ethernet
QPSK
RNS-101
DVB-S RADIO IPTV
STREAMER
RNS-101
DVB-S RADIO IPTV
STREAMER
SNS-101
DVB-S IPTV
STREAMER
SNS-101
DVB-S IPTV
STREAMER
SNS-101
DVB-S IPTV
STREAMER
SNS-101
DVB-S IPTV
STREAMER
SNS-101
DVB-S IPTV
STREAMER
SNS-101
DVB-S IPTV
STREAMER
POWER SUPPLY
+24V
CFP-500
DVB-S to IP Streaming Equipment
REF. 5112
Data Sheet

RNS-101 (Ref. 5112)
FTA or MultiCrypt DVB-S Radio ➞➞
➞➞
➞IP Streamer — Common Interface
Configuration and Settings
User Manual
Television on IP Networks

Configuration and Setting of the RNS-101 Streamer Module
September 2008
Revision A
IKUSI - Ángel Iglesias, S.A.
Paseo Miramón, 170
20009 San Sebastián
SPAIN
Tel.: +34 943 44 88 00
Fax: +34 943 44 88 11
www.ikusi.com
User Manual
EN

CONTENTS
Introduction ............................................................................................................................. 4
This Manual ................................................................................................................. 4
Product Description...................................................................................................... 4
Chapter One - Configuration of the RNS-101 Streamer ......................................................... 5
Configuration........................................................................................................... 6-10
Save/Restore Configuration ....................................................................................... 11
General Report .......................................................................................................... 12
Chapter Two - RNS-101 Streamer Settings .......................................................................... 13
DiSEqC Configuration ................................................................................................ 14
Input Settings ........................................................................................................ 15-17
Output Settings ..................................................................................................... 18-20
SAP/SDP Channel Settings ....................................................................................... 21
CAM User Menu ........................................................................................................ 22
SNMP Configuration ............................................................................................. 23/24
Chapter Three - RNS-101 Streamer Status Information ....................................................... 25
Status Information ...................................................................................................... 26
Chapter Four - RNS-101 Streamer Reports ......................................................................... 27
Input Services ............................................................................................................ 28
Output Streams .......................................................................................................... 29
System Logs .............................................................................................................. 30
3

4
This Manual
This manual describes the configuration and settings programme for the RNS-101 Streamer Module.
It is the second part of the user documentation for said module, the first part of which is the Installation
and Access manual supplied in paper format.
Product Description
RNS-101 streamers are DVB-S to IP gateways designed to broadcast in multicast on an IP network up to
28 Radio programmes issued from FTA or encrypted digital satellite reception; in case of encrypted signal,
a CAM containing the operator's smart card must fit the front panel slot. The IP streams can be listened using
an IPTV set-top box or a software video/audio player.
RNS-101 modules have an IKUSI ClassA mechanical format. As such, they are fixed to BAS-700 / BAS-900
baseplates or to an SMR-601 rack frame, and are +12 VDC powered from a CFP module.
Characteristics
●Input: 1 DVB-S transponder signal with FTA or encrypted Radio programmes. Output: up to 28 simultaneous IP-encapsulated
Radio programmes, with individual multicast addresses.
●Information filtering of DVB tables.
●UDP & RTP transmission protocols.
●Web interface for configuration and setting.
●Alarm information SNMP agent.
●SAP & SDP protocols which facilitate automatic service selection on the user's STB and the supply of information to external
servers.
ADVANCED
PID filtering
PSI/SI parsing
Transparent ECM & EMM messaging
PAT and PMT table regeneration
Routing or blocking for CAT, NIT, SDT, EIT, TDT tables
Configurable QoS marking
Configurable Time To Live
Programme Access Screen
Introduction
Once the desired programme language has been chosen [ English (en), Spanish (es), French (fr) ],
enter the password and click on OK.
Note: The default password — admin — can (and must) be changed as explained on page 9.
When the connection is established between the RNS-101 streamer and the control PC, the programme
access screen appears:

Chapter One - Configuration of the RNS-101 Streamer
In this Chapter
● Configuration
● Save/Restore
● General Report
5

6
General Configuration
Figure 1.1 - Initial programme screen
Figure 1.2 - Identification card of the Configuration window.
Initial program screen
The first screen that appears
when the programme is
accessed contains the "Output"
window, which gives information
on the IP streams that have
been created on the module and
which may or may not be
incorporated into the output data
stream.
On the left of this screen are the
menus that access all of the
programme's functionalities.
Click on the General menu on the left of the screen to display a dropdown list
containing the 3 options: Configuration, Save/Restore and General Report.
Click on Configuration. The Configuration window will appear :
Identification
The identification card (Figure 1.2) provides basic data on the RNS-101 streamer. The
different card fields are completed as follows:
Configuration

7
"Model": RNS-101. This data cannot be changed.
"Serial Number": Informational data which cannot be changed.
"Firmware Version": As above.
"Identifier": Any name that the installer or operator wishes to assign to the streamer
module can be entered here.
"Location": Enter the postcode of the installation site if required.
"Installer": The installer's identification details can be entered here.
"Contact": Then enter their contact details (telephone number, email).
"Installation date": The date on which the streamer module was installed can be
entered here.
Click on the Save button at the bottom of the window to store the information on the streamer module, this
information is then shown each time the module is accessed.
Configuration

8
Network
Click on the Network tab to configure the streamer's ethernet connection parameters.
The following card is displayed:
Figure 1.3 - Network card of the Configuration window.
"Use DHCP to get IP address": If this box is checked, the RNS-101 module will use
the DHCP protocol for assigning dynamic IP addresses. Consequently, no data
needs to be entered in the next five fields on the tab.
If the administrator of the network on which the SNS headend is installed assigns
static IP addresses, the box will not be checked and the following fields will need to
be filled in.
WARNING: If this option is activated, the IP address assigned to the streamer can
only be known by consulting the DHCP server management system.
"IP Address": Enter the IP address that you wish to assign to the streamer. This
address must fall within the range of local network addresses.
"Network mask": Enter the local network mask.
"Default gateway": Enter the IP address of this gateway. This information is only
required if you want the streamer to access Internet.
"Primary DNS server": Enter the primary server's IP address. Equally, this
information is only required if you want the streamer to access Internet.
"Secondary DNS server": Enter the same information for the secondary server.
"MAC Address": The physical address of the streamer's ethernet network card is
displayed automatically.
Once you have filled in all of the required information, click on Modify Network Configuration. If, at the last moment,
you decide to keep the current settings, click on Restore.
Configuration
This manual suits for next models
1
Table of contents
Other IKUSI Media Player manuals