ICON STAGE User manual

STAGE
USER MANUAL
KEEP THIS MANUAL FOR FUTURE NEEDS

ICON STAGE USER MANUAL
1
CONTENTS
1. SAFETY INSTRUCTIONS………………………………………………………………………………… 2
IMPORTANT SAFETY WARNING………………………………………………………………………. 2
GENERAL GUIDELINES ………………………………………………………………………………… 3
2. FEATURES ……………………………………………………………………………….………………….. 4
3. FIXTURE OVERVIEW……………………………………………………………………………………... 6
4. DIMENSIONAL DRAWINGS……………………………………………………………………………… 7
5. INSTALLATION INSTRUCTIONS…………………………………………………………………………. 8
RIGGING THE DEVICE …………………………………………………………………………………... 8
RIGGING USING THE OMEGA BRACKET……………………………………………………………... 9
RIGGING DRAWINGS……………………………………………………………………………………. 10
6. DMX-512 CONTROL CONNECTION…………………………………………………………………… 11
7. DMX-512 CONNECTION WITH DMX TERMINATOR ………………………………………………... 11
8. DEVICE DMX START ADDRESS SELECTION ………………………………………………………. 12
9. DISPLAY ……………………………………………………………………………………………………. 12
Address ……………………………………………………………………………………………………. 15
Config ……………………………………………………………………………………………………… 15
Reset Function ……………………………………………………………………………………………. 17
Communication……………………………………………………………………………………………. 17
Info………………………………………………………………………………………………………….. 18
Test…………………………………………………………………………………………………………. 20
10. DMX PROTOCOL………………………………………………………………………………………….. 21
11. ERROR MESSAGES………………………………………………………………………………………. 27
12. CLEANING AND MAINTENANCE……………………………………………………………………….. 30

ICON STAGE USER MANUAL
2
1. SAFETY INSTRUCTIONS
1.1. IMPORTANT SAFETY WARNING
This device has left the factory in perfect condition. In order to maintain this condition and to ensure safe
operation, it is absolutely necessary for the user to follow the safety instructions and warning notes written
in this user manual.
In order to install, operate, and maintain the lighting fixture safely and correctly we suggest that the
installation and operation be carried out by qualified technicians and these instructions be carefully
followed.
CAUTION!
HIGH VOLTAGE. RISK OF SEVERE OR FATAL ELECTRIC SHOCK
CAUTION!
ALWAYS DISCONNECT MAINS SUPPLY BEFORE REMOVING ANY FIXTURE COVERS
CAUTION!
NEVER LOOK DIRECTLY INTO THE LIGHT SOURCE. SENSITIVE PERSONS MAY SUFFER
AN EPILEPTIC SHOCK
CAUTION!
NEVER TOUCH THE DEVICE DURING OPERATION! COVERS MAY BE HOT
CAUTION!
KEEP THIS DEVICE AWAY FROM RAIN AND MOISTURE
Important:
Damage caused by the disregard of this user manual is not subject to warranty. The dealer
and manufacturer will not accept liability for any resulting defects or problems.
1) If the device has been exposed to temperature changes due to environmental conditions, do
not power on immediately. The resulting condensation could damage the device. Leave the
device powered off until it has reached room temperature.
2) This device falls under protection-class I. Therefore, it is essential that the device be earthed.
3) If either lenses or display are damaged (damage may include cracks or gashes in the material)
they must be replaced.
4) Electrical connections, such as replacing the power plug, must be performed by a qualified
person.
5) Make sure that the available voltage is not higher than that which is stated at the end of this
manual.
6) Make sure the power cord is never crushed or damaged by sharp edges. (If the Power cord
suffers from this case, the cable must be replaced by an authorized dealer.)
7) If the external flexible power cord of this device is damaged, it shall be exclusively replaced by
the manufacturer or their service agent or a similar qualified person in order to avoid injury.
8) When the device is not in use or before performing maintenance, always disconnect the device
from the mains. Only handle the power cord from the plug. Never pull the plug out of a socket
by tugging the power cord.
9) When powered on for the first time, some smoke or smell may occur. This is caused by the
coating on the metal parts when it is heated. And it is normal. If you are concerned, please
contact your distributor.
10) Do not focus the beam onto flammable surfaces. The minimum distance between the exiting

ICON STAGE USER MANUAL
3
lens of the device and the illuminated surface must be greater than 2 meters.
Please be aware that damages caused by any modifications to the device are not subject to
warranty. Keep away from children and non-professionals.
1.2. GENERAL GUIDELINES
1) This device is a lighting effect for professional use on stages, in discotheques, theatres, etc.,
the device is designed for indoor use only.
2) This fixture is only allowed to be operated within the maximum alternating current as stated in
the technical specifications in section 2 of this manual.
3) Handle the device with care, avoid shaking or using force when installing or maintaining the
device.
4) When choosing the installation location, please make sure that the device is not exposed to
extreme heat, moisture or dust.
5) If you use the quick lock cam when rigging the device, make sure the quick lock fasteners are
located in the quick lock holes correctly and securely.
6) Operate the device only after having familiarized yourself with its functions. Do not permit
operation by persons not qualified for operating the device. Most damages are the result of
unprofessional operation.
7) Please use the original packaging if the device is to be transported.
8) The applicable temperature for the device is between -10°C to 45°C. Do not use the device
outside of this temperature range.
9) The light source contained in this luminaire shall only be replaced by the manufacturer or his
service agent or a similar qualified person
For safety reasons, please be aware that all modifications to the device are forbidden. If this device
is operated in any way different to the ones described in this manual, the product may suffer
damage and the warranty becomes void. Furthermore, any other wrong operations may lead to
short-circuits, burns, electric shocks etc.

ICON STAGE USER MANUAL
4
2. FEATURES
1) POWER SUPPLY
+ AC 100-240V~,50/60Hz
+ Power Consumption:600W
2)
OPTICS
+ LED:White 420W LED
+ Extremely long Life:>20,000H
3)
MOVEMENT
+ Pan movement:540。 /630。 Optional (16 bit)
+ Tilt movement:270。 (16 bit)
+ Advanced moving system:fast,stable and quite,auto x-y repositioning
4) COLORS
+ CMY & CTO Variable Color Mixing for Infinite Color Possibilities
+ 1 Color wheel: 7 dichroic filters + open, indexable, rainbow effect
5) GOBOS
+ 1 Rotation gobo wheel:7 interchangeable,rotating,and indexable,gobo + open
+ “Slot in & out” gobo wheel system
+ 1 Static gobo wheel:8 + open
6)
FEATURES
+ 2 Control channel modes:34/58 channels
+ 2 operations modes:DMX-512,Extended / Standard
+ Strobe effect with 1-25 flashes per second and pulse effect
+ Rotating Prism:5 facets prism,Linear prism and prism Macros
+ Animation wheel:can make special dynamic flame or water effect
+ Beam angle:zoom for 8.2。~56。
+ Motorized focus
+ Dimmer:0%~100% full range dimming
+ Stepless frost:0%~100% linear change frost
+ Stepless iris:5%~100% linear change iris,pulse iris effect
7)
DISPLAY
+ Advanced and convenient full –color LCD touch screen, with rechargeable battery
+ Locked automatically after standby for 15 seconds to prevent error;hold the button for 3
seconds to activate
+ Pan/Tilt Lock Out:Locks Pan / Tilt from resetting, enabling reset to be carried out inside a flight
case. Power the unit. Press & hold button until the display shows “No Movement
Reset”.
8)
SOFT
WARE
+ Upgrades:fast and convenient through DMX cable
+ Reset DMX address, remote lamp switch, reset can all be done by the controller

ICON STAGE USER MANUAL
5
+ Running time of fixture on display for reference
9)
OTHER SPEC
+ Input signal isolation: guarantees stable signal transmission without interference
Advanced RDM function
10) WEIGHT
+ Net weight:31 kg
11) PHOTOMETRIC DATA

ICON STAGE USER MANUAL
6
3. FIXTURE OVERVIEW
1) Lens
2) Tilt Lock
3) Display
4) Mode/Esc-button
5) Left-button
6) Down-button
7) ENTER-button
8) Right-button
9) Up-button
10) Pan Lock
11) RJ45 in
12) RJ45 out
13) DMX out
14) DMX in
15) Power in
16) Power out
17) Fuse
18) Handle

ICON STAGE USER MANUAL
7
4. DIMENSIONAL DRAWINGS

ICON STAGE USER MANUAL
8
5. INSTALLATION INSTRUCTIONS
5.1 RIGGING THE DEVICE
CAUTION!
PLEASE CONSIDER THE GB7000.1-2015, GB7000.217-2008 AND THE OTHER
RESPECTIVE NATIONAL NORMS DURING THE INSTALLATION. THE INSTALLATION
MUST ONLY BE CARRIED OUT BY A QUALIFIED PERSON.
+ The structure on which the device is rigged must be able to support 10 times the weight of the
device for 1 hour without any critical deformation occurring.
+ The installation must always be secured with a secondary safety attachment, e.g. the included
appropriate safety cable.
+ Never stand directly below the device when rigging, de-rigging or maintaining the device.
+ All electrical connections should be approved by a qualified electrician prior to using the product.
+ When the device is permanently installed these installations have to be approved by a qualified
person once a year.
+ Overhead rigging requires extensive experience, including (but not limited to) calculating working
load limits, specifying installation/ rigging materials, and periodic safety inspection of all
installation material as well as the device. If you lack these qualifications, do not attempt the
rigging of this device yourself. Improper installation/ rigging can result in serious bodily injury.
+ Before rigging make sure that the installation area can hold a minimum point load of 10 times the
device’s weight.

ICON STAGE USER MANUAL
9
5.2 RIGGING USING THE OMEGA BRACKETS
1) Fix the clamp to the bracket by tightening the M12 nut and bolt to the bracket through the Ф13 hole
in the middle of the bracket.
2) Insert the quick-lock fasteners of the first Omega holder into the respective holes on the bottom of
the device. Tighten the quick-lock fasteners fully clockwise.
3) Install the second Omega holder.
4) Pull the safety cable through the holes on the bottom of the base and over the trussing system or
another suitable rigging point. Insert the end into the carabiner and tighten the safety screw.
Important:
This step is very important to ensure safe rigging of the fixture.
Table of contents
Other ICON Floodlight manuals