hylite Mightylite MFL015 Manual

Mightylite 15W / 24W LED Floodlights
Model: MFL015 / MLF024
Installation & operating instructions
F4 Enterprises Limited
7 Abbey Square, Chester
CH1 2HU, UK
Tel: +44 (0)1352 736120
www.f4enterprises.co.uk
Fig.7
Fig.6
Fixing Holes
FIXING THE CONNECTION BOX (Cont)
• UsetheconnectionboxFixingHoles[Fig.6]tomarkthe4drillholesrequiredto
securetheboxtothewall(andmarkthecableoutletlocationifrequired).Drill
thewallandscrewtheconnectionboxontothewallusingthescrewsandwall
plugsprovided.
• Oncethewire(s)hasbeenfedthroughtheSealingGland,thenutonthegland
shouldbegentlytightenedupagainsttheglandbody[Fig.8]toensurethe
wire(s)issecuredinplaceandnowatercangetthoughintotheconnectionbox.
WIRING THE FLOODLIGHT
• Oncethepowercablehasbeenfedthroughthecablegland(orsealing
grommetifusingtheknock-outattherearoftheconnectionbox)
approximately6mmofinsulationshouldbestrippedfromeachofthecoresof
ACcablereadytoattachittotheterminalblockinthefrontofthelighttting.
NOTE: The Hylite Mightylite is a Class 2 fitting, therefore no Earth is required
CONNECTING TO POWER SUPPLY
• ConnecttheBROWNorRED(Live)wiretotheterminal(marked“L”)holdingthe
singleBROWNwireintheoodlightunit[Fig.8].
• ConnecttheBLUEorBLACK(Neutral)wiretotheterminal(marked“N”)holding
theBLUEwireintheoodlightunit.
• Aftertheconnectionshavebeensecured,theoodlightfront(ConnectionBox
front)shouldbefastenedtotheConnectionBoxusingthe4ConnectionBox
Screwsprovided[Fig.9]
• Oncescrewsaresecure,thescrewcovers(provided)shouldbettedshouldbe
tted[Fig.9]
• ToadjusttheMightyLitesimplyholdtheConnectionBoxrmlywhilstmoving
theheadoftheoodlighttotherequiredposition.
Fig.9
Fig.8

WIRING REQUIREMENTS
Fig.1
FUSE
3 AMP FUSE
TO LAMP
FROM MAINS
SUPPLY
DOUBLE-POLE SWITCHED FUSED SPUR
F
1
2
5
4
3
T R
PIR
sensor
More sensitiveLess sensitive
L
N
SL
E
Override switch
Live
C L1
Neutral Earth
To Mains MightyLite
N In N Out
L In L Out
Theunitrequiresconnectiontoa230AC50Hzmainselectricitysupply.
Itisrecommendedthattheunitisconnectedtothedomesticlightingcircuitviaa
5ampfusedspurandusing2-coreroundexiblecableofatleast1mm2gauge
(waterproofcableshouldbeusedforoutdoorinstallations).
Itisalsoadvisabletoinstallasinglepolewallswitchtoalloweasycontrolofthe
oodlight(Fig.1).
IMPORTANT OPERATION & MAINTENANCE INSTRUCTIONS
TheHyliteMightyliteoodlightalowenergy,highpoweredoutdoorLEDoodlightwhichissuitableforinstallationonsolid
wallsinarangeoflocationsincludingentrances,gardens,staircases,garagesandoutdoorparkingareas.
Theunitrequiresconnectiontoa230AC50Hzmainselectricitysupply.
IMPORTANT SAFETY INSTRUCTIONS
HYLITE MIGHTYLITE – INSTALLATION AND OPERATING INSTRUCTIONS
DONOTpositionthelightnearammableorcombustiblematerials(suchasclothorpaper)ornearammable,
combustibleorexplosiveliquids,solids,gasesorequipment.
DONOTlookdirectlyintothelightorpointittowardsaperson’seyes.Thislighthasaveryintensivelightoutputwhich,
ifincorrectlyused,couldcauseeyedamage.
ALWAYSdisconnectthemainspowersupplybeforeinstalling,servicingorperforminganymaintenance.
ALWAYSmaintainthelightingoodcondition,withrepairsonlyundertakenbyaqualiedelectrician.
ONLYcarryoutrepairsusinggenuineparts.Non-authorisedpartsmaybedangerousandwillinvalidatethewarranty
WARNING: THIS PRODUCT MUST BE INSTALLED BY A QUALIFIED ELECTRICIAN, AND CHECKED TO ENSURE IT IS SAFE BEFORE USING
PLEASEFOLLOWTHESEINSTRUCTIONSCAREFULLYBEFOREATTEMPTINGTOINSTALLANDOPERATETHISLIGHT
Theriskofelectricshockshouldbeminimizedbytheinstallationofappropriatesafetydevicesincludingthe
incorporationofanRCCB(ResidualCurrentCircuitBreaker)intothemaindistributionboard.
DONOTwirethisoodlightdirectlyintothelightingcircuit.Useaswitchedfusedspur.Cablesshouldalwaysbe
protectedagainstshortcircuitandoverloadbyuseofanRCD.
Ensurethevoltagemarkedontheproductisthesameastheelectricalpowersupplytobeused.
DONOTinstallthelightwhereitislikelytobeknockedorhit;inhotorhumidconditionssuchasbathrooms,shower
roomsorsaunas;ornearanexhaustoutlete.g.boilerue,dryeroutlet.
TOOLS REQUIRED
Electric/hand-helddrill
No.8masonrydrillbit
Electriciansscrewdriver
Largecross-headscrewdriver
Smallcross-headscrewdriver
Wire cutters
THISPRODUCTISSUITABLEFORWALLMOUNTINGONLY.
PARTS INCLUDED
1 x Mightylite LED Floodlight
1xConnectionbox
1xCablegland
4xConnectionboxscrews
4xConnectionboxscrewcovers
4xConnectionboxxingscrews
4xConnectionboxxingscrewcovers
Fig.2
FUSE
3 AMP FUSE
TO LAMP
FROM MAINS
SUPPLY
DOUBLE-POLE SWITCHED FUSED SPUR
F
1
2
5
4
3
T R
PIR
sensor
More sensitiveLess sensitive
L
N
SL
E
Override switch
Live
C L1
Neutral Earth
To Mains MightyLite
N In N Out
L In L Out
3-5m
Fig.5
Fig.4
Fig.3
Landscape
Portrait
FIXING THE CONNECTION BOX
WARNING: Isolate the power supply before installation.
• Positiontheunitonthewallandmarkthepositionfortheconnectionbox
(whichcanbepositionedineitherlandscapeorportraitplanes[Fig.3]).
• Ensurethewirescaneasilyentertheconnectionboxthrougheitheroneofthe
knock-outsonthesideoftheconnectionbox,orthroughtheknock-outatthe
rearofthebox.
NOTE: It is recommended that the knock-outs on the sides of the
connection box are used in conjunction with the cable gland [Fig 4.] as
using the knock-out at the rear of the connection box will reduce the
weatherproof rating of the unit to IP23.
• However,Iffeedingawire(s)throughtheknock-outattherearoftheconnection
box,thiswillneedtoberemoved,thesealinggrommettted[Fig.5]andthe
wirepushedthroughintotheconnectionboxBEFOREitissecuredtothewall.
• Iffeedingawire(s)throughthesideknock-outs,itiseasiesttotthecable
glandtotheconnectionbox[Fig.4]BEFOREsecuringittothewall,andwires
shouldentertheconnectionboxfromthesidesorunderneath,NOTfromthetop.
CHOOSING A MOUNTING LOCATION
INSTALLATION INSTRUCTIONS
• Mounttheoodlightontosolidbrickorwoodwork,3-5mabovetheground
[Fig.2]
• Avoidpositioningthelightnearheatsourcessuchashotventilatorducts,air
conditioningunits,streetlightingortrafcwhichmayinterferewithitsoperation.