6
4 Installation
Before using the tool for the first time check it carefully for signs of external
damage. If any shipping damage is found DO NOT USE THE TOOL - return it to
your supplier immediately.
1. Assemblethe standtothemaincontrolunit byattaching theverticalmountingpole(the
longerbarsupplied)intotheverticalsupport bracketonthecontroloftheunit. Tighten
theM4 fromthesideofthesupport brackettosecure theverticalmountingpole.
2. Assemblethe slide assemblytothestand.
3. SecuretheslideassemblybytighteningtheM6 screwontheslide assemblybracket.
4. Connect the Cylinder Extend and Cylinder Retract Air hoses to the Cyl Extend
and Cyl Retract ports on the back of the unit.
5. Connect the Advance Slide Cable to the Advance Slice Limit Switch connector
of the back of the unit.
6. Plugthepower adapterwithcordintothe“24VDC”inputonthebackofthecontrollerand
intothewallsocket.
Notice: The power adapter has auto ranging power function that can be used
with either 110 or 220V and 50 or 60 Hz.
7. Connectthefootswitch,orPLCstartsignalcable,tothe“StartSwitchXS1”connectoron
thebackofthecontroller.
8. Connecttheairinputlineto theAirInputfittingusing6mmO.D.pneumatictubing(not
supplied).
9. Turn on the local airsupply. This must be a minimum of 80 psi anda maximum of 125
psi.
Warning! When the air is connected, the slide may retract. Be sure to keep
your hands and other objects clear of the slide before connecting the air.
Caution! Clean, dry, filtered air must be used. If it is not, the solenoids in the
controller will be fouled over time. If the required air quality is not achieved,
install a Loctite®filter regulator. In the US order a 5 m filter using Part Number