HEIL 1 For All TSTAT0713 User manual

INSTALLATION MANUAL
P/N TSTAT0713
Meets Residential California Title 24
International Comfort Products 2005
HEAT
PUMP
HEAT
COOL &
2 HEAT - 2 COOL
MULTI-STAGE PROGRAMMABLE
ModeCooler Warmer
Programmable
Temperature & Humidity
1 For All
Digital Thermostat
Complete Control
70 o
o
78
AUTO
HEAT
COOL
74
o
Am
8 00
:
M
616 01 1012 00

P/N TSTAT0713
International Comfort Products 2005
Table Of Contents
PREPARATION
REMOVE OLD THERMOSTAT
INSTALL BACKPLATE & WIRE
WIRING DIAGRAMS
CALIBRATION
TEST OPERATION
TROUBLESHOOTING
Page 1
CAUTION
WARNING
2
3
4
5
13
15
14
This device complies with Part 15 of the FCC rules.
Operation is subject to the following 2 conditions:
(1) This device may not cause harmful interference,
and (2) This device must accept any interference
received, including interference that may cause
undesired operation.
Follow Installation Instructions carefully.
DISCONNECT POWER TO THE HEATER
AND AIR CONDITIONER BEFORE
REMOVING THE OLD THERMOSTAT AND
INSTALLING THE NEW THERMOSTAT.

Proper installation of the TSTAT0713 will be
accomplished by following these step
by step instructions. If you are unsure
about any of these steps, call a qualified
technician for assistance.
Assemble tools as shown below.
Flat Blade
Screwdriver
Wire cutter
& Stripper
Drill with 3/16
inch Drill Bit
(when not using
j-box)
Make sure your Heater/Air Conditioner
is working properly before beginning
installation of the TSTAT0713.
Carefully unpack the TSTA0713.
Save the screws, wall anchors, and
instructions.
STEP #1
PREPARATION
Page 2
70 o
o
78
AUTO
HEAT
COOL
74
o
Am
8 00
:
M
70 o
o
78
AUTO
HEAT
COOL
74
o
Am
8 00
:
M
70 o
o
78
AUTO
HEAT
COOL
74
o
Am
8 00
:
M
70 o
o
78
AUTO
HEAT
COOL
74
o
Am
8 00
:
M

Turn off the power to the Heating/Air
Conditioning system at the main fuse
panel. Most residential systems have
a separate breaker for disconnecting
power to the furnace.
Remove the cover of the old thermostat.
If it does not come off easily check for
screws.
Loosen the screws holding the thermostat
base or subbase to the wall, and lift away.
Disconnect the wires from the old
thermostat. Tape the ends of the wires
as you disconnect them, and mark them
with the letter of the terminal for easy
reconnection to the new thermostat.
STEP #2
REMOVE OLD THERMOSTAT
Page 3
Keep the old thermostat for reference
purposes, until your new thermostat is
functioning properly.
70 o
o
78
AUTO
HEAT
COOL
74
o
Am
8 00
:
M
70 o
o
78
AUTO
HEAT
COOL
74
o
Am
8 00
:
M
70 o
o
78
AUTO
HEAT
COOL
74
o
Am
8 00
:
M
70 o
o
78
AUTO
HEAT
COOL
74
o
Am
8 00
:
M
70 o
o
78
AUTO
HEAT
COOL
74
o
Am
8 00
:
M

STEP #3
INSTALL BACKPLATE & WIRE
Page 4
Function
Wire from the
old thermostat
terminal marked
G
Y1
W1
W1,O,B*
W2
Y2
HUM
DEHUM
RS+5
RS1
RSGND
R
C
Fan
Cooling
Heating
Power
Common
Rev. Valve
2nd Stage Heat
2nd Stage Cool
Humidifier Control
Dehumidifier Control
Remote Sensor +5vdc
Remote Sensor Signal
Remote Sensor Ground
G or F
Y1, Y or C
W1, W or H
Rh, R, M, Vr, A
C*
O/B
W2
Y2
HUM
DEHUM
RS+5
RS1
RSGND
Install on the
new TSTAT0713
terminal marked
* O or b is used if the system is a Heat Pump.
If the terminal designations on your old
thermostat do not match those on the
new TSTAT0713, refer to the chart below,
or the wiring diagrams that follow.
Remove the backplate connector from the rear
of the TSTAT0713 and attach it to the wall.
Install wires as directed below. When finished,
snap TSTAT0713 on to backplate.
70 o
o
78
AUTO
HEAT
COOL
74
o
Am
8 00
:
M
70 o
o
78
AUTO
HEAT
COOL
74
o
Am
8 00
:
M

Sample Wiring Diagrams
Page 5
W1/O/B
Y1
G
HUM
R
C
W2
Y2
DEHUM
RS+5
RS1
RSGND
5 conductor, 18 gauge
unshielded cable from the
thermostat to the equipment.
24 vac return
Fan relay
Compressor relay
1st stage heat circuit
W1 GR C
Y1
24 vac common
DEHUM
DEHUM terminal
on HVAC unit
(if available)
5 Wire, 1 Stage Cooling, 1 Stage Heat
Residential Gas or Electric Heat*,
Electric Cool, split systems & package
units
Optional wiring for
dehumidification
* If using electric heat this, option must
be set to ON during Advanced Setup.
Pages 8, 19-20, and 24 of Owner’s Manual

Sample Wiring Diagrams
Page 6
W1/O/B
Y1
G
HUM
R
C
W2
Y2
DEHUM
RS+5
RS1
RSGND
24 vac return
Fan relay
Compressor relay
1st stage heat circuit
W1 GR C
Y1
24 vac common
DEHUM
Residential 2 Stage Cooling with
Gas or Electric Heat*
6 Wire, 2 Stage Cooling, 1 Stage Heat
2nd stage
compressor relay
Y2
6 conductor, 18 gauge
unshielded cable from the
thermostat to the equipment.
DEHUM terminal
on HVAC unit
(if available)
Optional wiring for
dehumidification
* If using electric heat this, option must
be set to ON during Advanced Setup.
Pages 8, 19-20, and 24 of Owner’s Manual

Sample Wiring Diagrams
Page 7
W1/O/B
Y1
G
HUM
R
C
W2
Y2
DEHUM
RS+5
RS1
RSGND
24 vac return
Fan relay
Compressor relay
1st stage heat circuit
W1 GR C
Y1
24 vac common
DEHUM
6 Wire, 1 Stage Cooling, 2 Stage Heat
2nd stage
Heat Circuit Relay
W2
Residential & Commercial 1 Stage Cooling
with 2 Stage Gas or Electric Heat*
6 conductor, 18 gauge
unshielded cable from the
thermostat to the equipment.
DEHUM terminal
on HVAC unit
(if available)
Optional wiring for
dehumidification
Pages 8, 19-20, and 24 of Owner’s Manual
* If using electric heat this, option must
be set to ON during Advanced Setup.

Sample Wiring Diagrams
Page 8
W1/O/B
Y1
G
HUM
R
C
W2
Y2
DEHUM
RS+5
RS1
RSGND
24 vac return
Fan relay
Compressor relay
1st stage heat circuit
W1 GR C
Y1
24 vac common
2nd stage
heat circuit relay
W2
7 Wire, 2 Stage Cooling, 2 Stage Heat
Commercial Gas or Electric Heat *,
Electric Cool, split systems & package units,
including Commercial Heat Pumps **
DEHUM
2nd stage
compressor relay
Y2
* If using electric heat this option must
be set to ON during Advanced Setup.
** Commercial heat pumps do not have
the heat pump turned on in Advanced Setup.
7 conductor, 18 gauge
unshielded cable from the
thermostat to the equipment.
DEHUM terminal
on HVAC unit
(if available)
Optional wiring for
dehumidification
If using a Residential heat pump,
this option must be set to ON
during Advanced Setup.
Pages 8, 19-20, and 24 of Owner’s Manual

Sample Wiring Diagrams
Page 9
W1/O/B
Y1
G
HUM
R
C
W2
Y2
DEHUM
RS+5
RS1
RSGND
5 conductor, 18 gauge
unshielded cable from the
thermostat to the equipment.
24 vac return
Fan relay
Compressor relay
OGR C
Y1
24 vac common
DEHUM
DEHUM terminal
on HVAC unit
(if available)
5 Wire, 1 Stage Cooling, 1 Stage Heat - Heat Pump
Optional wiring for
dehumidification
Residential Heat Pumps*, split systems & package units.
No auxiliary heat.
Reversing valve
(Fail to Heat)
* If using a Residential heat pump,
this option must be set to on
during Advanced Setup.
Pages 8, 19-20, and 24 of Owner’s Manual
Table of contents
Popular Thermostat manuals by other brands

Saswell
Saswell SAS920XWHB-7-S-RF User manual and warranty card

Aircalo
Aircalo TFP1-ET85P2 operating manual

Honeywell
Honeywell CM721 user manual

Carrier
Carrier DEBONAIR 33CS Installation and operating instructions

Lennox
Lennox iHarmony Zone Thermostat Installation and setup guide

Gemtech
Gemtech GT7000 Operation