To adjust the scale of the temperature dial to match the actual room
temperature, the dial itself has to be adjusted mechanically.
CALIBRATE TEMPERATURE
1. The temperature in the room must have been stable for approx. 30
minutes.
2. Insert at nose screwdriver in between the dial and the front fascia,
gently moving the screwdriver up and down until the dial comes
loose.
3. Turn the center knob clockwise until heating is activated and then
slowly counter clockwise until heating is off again.
4. With a thermometer, measure the actual room temperature and
install the dial indicating this temperature.
Supply voltage 110-240 V / 50-60 Hz
Max. load 3600 W
IP class IP20
Temperature range +5° C ... +40° C
Sensor settings Floor sensor
Operation Dial
Floor sensor type 10 KΩ @25°C, length 3m
Colour White, RAL 9003
Dimensions 81 x 81 x 51 mm
Standards LVD 2014/35/EU • EN60730-1 •
EN60730-2-9 • EN50081-1 • EN50082-1
• REACH regulation (EC) No. 1907/2006
SPECIFICATIONS